Çѱ¹°Ç¼³°ü¸®ÇÐȸ / v.7, no.3, 2006³â, pp.112-121
¿ÀÇǽººôµù ³Ã³­¹æ½Ã½ºÅÛÀÇ ¼ö¸íÁÖ±âºñ¿ë ºÐ¼®¿¡ °üÇÑ ¿¬±¸ : Èí¼ö½Ä ³Ã¿Â¼ö À¯´ÖÀÇ ¼³Ä¡ À¯ÇüÀ» Áß½ÉÀ¸·Î ÇÑ »ç·Ê¿¬±¸
( A Study on the LCC Analysis of an Office Building HVAC System )
¹Ú¹®¼±;½ÅÇü½Ä;±è¿ë¼ö; Áß¾Ó´ëÇб³ °ÇÃà°øÇаú;Áß¾Ó´ëÇб³ °Ç¼³°æ¿µ°ü¸®Çаú;Áß¾Ó´ëÇб³ °ÇÃà°øÇаú;
 
ÃÊ ·Ï
º» ¿¬±¸´Â »ç·Ê´ë»ó °Ç¹°ÀÇ ³Ã³­¹æ¼³°è¿ë·®¿¡ ´ëÇÑ ³Ã¿Â¼ö À¯´ÖÀÇ ¼³Ä¡ À¯ÇüÀ» ´ÜÀϼ³Ä¡, ºÐÇÒ¼³Ä¡(±ÕµîºÐÇÒ), ºÐÇÒ¼³Ä¡ (Â÷µîºÐÇÒ)ÀÇ À¯ÇüÀ¸·Î ±¸ºÐÇÏ¿© °¢°¢ÀÇ »ç·Ê¸¦ ¼±Á¤Çϰí LCC±â¹ýÀ» ÀÌ¿ëÇÑ °æÁ¦¼º Æò°¡¸¦ ½Ç½ÃÇÏ¿´´Ù. À̸¦ À§ÇÏ¿© ³Ã¿Â¼ö À¯´ÖÀÇ LCC ±¸¼ºÇ׸ñÀ» Á¶»çÇϰí, ±¸¼ºÇ׸ñº° ºñ¿ë ÀڷḦ Á¶»çÇÏ¿´´Ù. À§¿Í °°Àº °úÁ¤À» ÅëÇØ ¿¹ÃøµÈ °¢ ¼³Ä¡ À¯Çüº° LCC¸¦ »óÈ£ ºñ±³ ºÐ¼®ÇÔÀ¸·Î½á °æÁ¦¼º Æò°¡¸¦ ½Ç½ÃÇÏ¿´´Ù. »ó±â¿Í °°Àº ¸ñÀû°ú ¹æ¹ý¿¡ µû¶ó ÁøÇàµÈ º» ¿¬±¸ÀÇ °á°ú¸¦ ¿ä¾àÇÏ¸é ´ÙÀ½°ú °°´Ù: 1) ³Ã³­¹æ¼³°è¿ë·®¿¡ ´ëÇÑ ´ÜÀϼ³Ä¡ »ç·Ê¿Í ºÐÇÒ¼³Ä¡(±ÕµîºÐÇÒ), ºÐÇÒ¼³Ä¡(Â÷µîºÐÇÒ) »ç·Ê¸¦ ¼±Á¤Çϰí LCC ±¸¼ºÇ׸ñ¿¡ ´ëÇÑ ÀÚ·áÁ¶»ç¸¦ ÅëÇÏ¿© ÃʱâÅõÀÚºñ(³Ãµ¿±â ¼³Ä¡ºñ, ³Ã°¢Å¾ ¼³Ä¡ºñ, ÆßÇÁ¼³Ä¡ºñ), À¯Áö°ü¸®ºñ(±³Ã¼ ¼ö¼±ºñ, °¡½º¿¡³ÊÁöºñ, Àü±â¿¡³ÊÁöºñ), ÇØÃ¼ºñ(³ë¹«ºñ, Æó±âºñ, ÀÜÁ¸°¡Ä¡)¸¦ °í·ÁÇÏ¿© ´ÜÀ§¸éÀû´ç$(100m^2)$ºÐ¼®±â°£ 15³â µ¿¾ÈÀÇ LCC¸¦ ºÐ¼® ÇÏ¿´´Ù. 2) ³Ã¿Â¼ö À¯´ÖÀÇ ´ÜÀϼ³Ä¡, ºÐÇÒ¼³Ä¡(±ÕµîºÐÇÒ), ºÐÇÒ¼³Ä¡(Â÷µîºÐÇÒ)ÀÇ ¼³Ä¡ À¯Çü¿¡ µû¸¥ °æÁ¦¼º Æò°¡ °á°ú ¼³Ä¡ À¯Çü Áß ´ÜÀϼ³Ä¡ À¯ÇüÀÌ °¡Àå °æÁ¦ÀûÀÎ °ÍÀ¸·Î ºÐ¼® µÇ¾ú´Ù.
The purpose of this study is to execute economical analysis for two types of office building HVAC system using LCC technique : single vs, separated HVAC(equal partition installation, unequal partition installation) system. The research method of this study includes the case analysis and questionnaire surveys. The results of this study are as follows: (1) LCCs of 3 types of HVAC system are estimated and the most economical one is investigated as single HVAC system, (2) In this case study, the single HVAC system was investigated as 34% lower in LCC during 15 years per $100m^2$ compared to equal partition installation, as 41% compared to unequal partition installation.
 
Ű¿öµå
³Ã³­¹æ½Ã½ºÅÛ;¿ÀÇǽººôµù;°æÁ¦¼º Æò°¡;HVAC system;LCC;Office Building;economical analysis;
 
Çѱ¹°Ç¼³°ü¸®ÇÐȸ³í¹®Áý / v.7, no.3, 2006³â, pp.112-121