¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹°Ç¼³°ü¸®ÇÐȸ / v.12, no.5, 2011³â, pp.71-80
°Ç¼³ °ø»çÀÇ ¾ÈÀü¼º Çâ»óÀ» À§ÇÑ Ãæµ¹¹æÁöÇü ½Ã½ºÅÛ ÇöóÀ׳ÝÀÇ °³¹ß
( Development of a Systemized Flying Net for Safety Improvement in Architectural Building Construction )
ÀÌÁ¤È£;¹Ú¼±ÁÖ;±è¿µ¼®; ÀÎÇÏ´ëÇб³ ¿ø°¡°øÇבּ¸¼¾ÅÍ;°Ç¿ø ¿£Áö´Ï¾î¸µ;ÀÎÇÏ´ëÇб³ °ÇÃà°øÇаú;
 
ÃÊ ·Ï
°ÇÃà°ø»ç¿¡¼­´Â °íÃþ °ÇÃ๰ ½ÅÃà½Ã ³ë¹«ÀÚÀÇ Ãß¶ô ¿¹¹æ ¹× ³«ÇϹ°¿¡ ÀÇÇÑ ºÎ»óÀ» ¹æÁöÇϱâ À§ÇØ °ÇÃ๰ÀÇ ¼öÁ÷¸é¿¡ ¸Å 10m À̳»·Î ³«ÇϹ° ¹æÁö¸ÁÀ» ¼³Ä¡Çϵµ·Ï ±ÔÁ¤Çϰí ÀÖ´Ù. ù ´Ü ÀÌÈÄ ¼³Ä¡µÇ´Â ³«ÇϹ° ¹æÁö¸ÁÀÎ ÇöóÀ׳ÝÀº Áö»ó 8m À̻󿡼­ ¼³Ä¡ ¹× ÇØÁ¦ ÀÛ¾÷ÀÌ ÁøÇàµÇ¹Ç·Î ³ë¹«ÀÚÀÇ ÀÛÀº ½Ç¼ö°¡ »ç¸Á »ç°í¿Í Á÷°áµÇ´Â ¸Å¿ì À§ÇèÇÑ ÀÛ¾÷ÀÌ´Ù. ÃÖ±Ù °Ç¼³ ¾÷ü¿¡¼­´Â ÇöóÀ×³Ý ¼³Ä¡ ºú ÇØÁ¦ÀÛ¾÷ÀÇ À§Ç輺À» ÀνÄÇÏ¿© ´Ù¾çÇÑ ÇüÅÂÀÇ ÇöóÀ׳ÝÀ» °³¹ßÇÏ¿© »ç¿ëÇϰí ÀÖ´Ù. ±×·¯³ª ÇöÀç±îÁö °³¹ßµÈ ÇöóÀ׳ÝÀº ¿Á¿ÜÀÛ¾÷ ¹× ±¸Á¶»óÀÇ ¹®Á¦·Î ÀÎÇØ ³ë¹«ÀÚÀÇ Ãß¶ô ³«ÇÏ µî ¾ÈÀü»óÀÇ ¹®Á¦Á¡À» Áö´Ï°í ÀÖ´Â °ÍÀ¸·Î ºÐ¼®µÇ¾ú´Ù. º» ¿¬±¸ÀÇ ¸ñÀûÀº ¼±Ç࿬±¸¿¡ ÀÖ¾î ÃÖÀû ´ë¾ÈÀ¸·Î ¼±Á¤µÈ Ãæµ¹¹æÁöÇü ½Ã½ºÅÛ ÇöóÀ× ³ÝÀÇ ÇÁ·ÎÅäŸÀÔÀ» ½Ç¹°(Full-scale)Á¦ÀÛÇϰí, ÇöÀå½ÇÇèÀ» ÅëÇØ ±âÁ¸ Àç·¡½Ä ¹æ½Ä ´ëºñ Á¦¾ÈµÈ Ãæµ¹¹æÁöÇü ½Ã½ºÅÛ ÇöóÀ׳ÝÀÇ ¾ÈÀü¼º, »ý»ê¼º, ÀÛ¾÷ ÆíÀǼº, °æÁ¦¼º Ãø¸é¿¡¼­ÀÇ ¼º´ÉÀ» ºÐ¼®ÇÏ´Â °ÍÀÌ´Ù. ¶ÇÇÑ ÇöÀå½ÇÇèÀ» ÅëÇØ µµÃâµÈ Ãæµ¹¹æÁöÇü ½Ã½ºÅÛ ÇöóÀ׳ÝÀÇ ¹®Á¦Á¡¿¡ ´ëÇÑ °³¼±¹æ¾È(ºÎÀç °æ·®È­, ÁöÁö´ë ¹× ºê¶óÄÏÀÇ ¾ÈÁ¤¼º È®º¸, ÀÛ¾÷ °£¼· ¹æÁö)À» Á¦½ÃÇϰíÀÚ ÇÑ´Ù.
Flying net should be installed on every 3 or 4 construction floor from 8m above ground according to the rule. In the apartment housing construction, flying net installation work has been recognized the most dangerous work among the whole works because a small mistake of labors might make their death accident. Sub-contractors specialized in flying net have been developing various flying net types. However, most works of installing flying net as working with the developed system are performed outside the apartment housing, so that the risk of fall in works of installing supports and unfolding net is still high. Furthermore, as using the previously developed flying net labors might bump into the frame or the wire rope for supporting so that it makes secondary accidents. The objective of this research is to produce the proto-type of anti-collision flying net system based on the result of problem analysis on the installation and detachment process and suggest the improved anti-collision flying net system, which is able to improve safety and field applicability by conducting field experiment and analyzing performance.
 
Ű¿öµå
³«ÇϹ° ¹æÁö¸Á;ÇöóÀ׳Ý;°øµ¿ÁÖÅÃ;¼º´ÉºÐ¼®;Safety net;Flying net;Apartment housing;Performance analysis;
 
Çѱ¹°Ç¼³°ü¸®ÇÐȸ³í¹®Áý / v.12, no.5, 2011³â, pp.71-80
Çѱ¹°Ç¼³°ü¸®ÇÐȸ
ISSN : 2005-6095
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO201130662200922)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿