Çѱ¹Áö¹Ý°øÇÐȸ / v.12, no.2, 1996³â, pp.85-94
|
¸»¶ÒÁ÷°æÀÌ Àç´Ü¸»¶ÒÀÇ Æó»öÁ¤µµ¿Í ÁöÁö·Â¿¡ ¹ÌÄ¡´Â ¿µÇâ
( Effects of Pile Diameter on the Plugging Rate and Bearing Capacity of Open -Ended Piles ) |
| ¹é±ÔÈ£;±è¿µ»ó;À̽·¡; Æ÷½ºÄÚ°³¹ß(ÁÖ) ±â¼ú¿¬±¸¼Ò;Çѱ¹°úÇбâ¼ú¿ø Åä¸ñ°øÇаú ¹Ú»ç°úÁ¤, Çѱ¹°úÇбâ¼ú¿ø Åä¸ñ°øÇаú;;
|
|
|
 |
|
| |
| ÃÊ ·Ï |
| ¸»¶ÒÁ÷°æÀÌ °³´Ü¸»¶ÒÀÇ Æó»öÁ¤µµ¿Í ÁöÁö·Â¿¡ ¹ÌÄ¡´Â ¿µÇâÀ» ±Ô¸íÇϱâ À§ÇÏ¿© ÀÀ·Â»óÅÂ¿Í »ó´ë¹ÐµµÀÇ Á¶ÀýÀÌ °¡´ÉÇÑ ÅäÁ¶¿Í Á÷°æÀÌ ´Ù¸¥ ¼¼°³ÀÇ ¸ðÇü¸»¶ÒÀ» ÀÌ¿ëÇÏ¿© ¸ðÇü¸»¶Ò½ÇÇèÀ» ¼öÇàÇÏ¿´´Ù. ¸ðÇü¸»¶ÒÀº ¸»¶ÒÀÇ ÁöÁö·Â ¼ººÐÀ» ºÐ¸®ÃøÁ¤Çϱâ À§ÇÏ¿© Á÷°æÀÌ ´Ù¸¥ µÎ°³ÀÇ ÆÄÀÌÇÁ·Î ¸¸µé¾îÁ³´Ù. ½ÇÇè°á°ú¿¡ ÀÇÇÏ¸é ¸»¶ÒÀÌ ¿ÏÀüÆó»ö »óÅ·ΠµÇ´Â °üÀÔ±íÀÌ´Â ¸»¶ÒÁ÷°æ°ú Áö¹ÝÀÇ »ó´ë¹Ðµµ°¡ Áõ°¡ÇÒ¼ö·Ï Ä¿Áö´Â °ÍÀ» ¾Ë ¼ö ÀÖ¾úÀ¸¸ç, °üÀÔºñ¿Í °ü³»Åä ÁõºÐºñ°¡ µ¿ÀÏÇÏ´õ¶óµµ ´ÜÀ§ °ü³»Åä ÁöÁö·ÂÀº ¸»¶ÒÀÇ Á÷°æÀÌ Ä¿Áú¼ö·Ï °¨¼ÒÇÏ´Â °æÇâÀ» º¸¿´´Ù. ±×·¯³ª ±âÁ¸ÀÇ ÁöÁö·Â »êÁ¤½ÄÀº ¸»¶ÒÀÇ °üÀÔºñ³ª Æó»öÁ¤µµ°¡ µ¿ÀÏÇÑ »óÅ¿¡ ´ëÇÏ¿© °ü³»Åä ÁöÁö·ÂÀº ¸»¶ÒÀÇ Á÷¿µ¿¡ °ü°è¾øÀÌ ÀÏÁ¤Çϰųª Á÷°æÀÌ Áõ°¡ÇÒ¼ö·Ï Ä¿Áö´Â °á°ú¸¦ ÁÖ°í ÀÖ´Ù. ÀÌ´Â º» ¿¬±¸ÀÇ ½ÇÇè°á°ú¿Í »ó¹ÝµÇ´Â °ÍÀ¸·Î¼ °ü³»Åä ÁöÁö·ÂÀÇ »êÁ¤½Ã ¸»¶ÒÀÇ Æó»öÁ¤µµ »Ó¸¸ ¾Æ´Ï¶ó Å©±âÈ¿°úµµ °í·ÁÇÏ´Â °ÍÀÌ ÇÊ¿äÇÑ °ÍÀ¸·Î ¹àÇôÁ³´Ù. |
|
| Model pile tests, using a calibration chamber in which the stress state and the relative density can be controlled, were performed in order to study the effects of pile diameter on the plugging rate and bearing capacity of open-ended pile. The model piles used in the test series were devised so that the bearing capacity of an open-ended pile could be measured out into three components. The test results showed that fully plugging depth of an open -ended pile increased with increase in pile diameter and soil density. Moreover, it was found that unit plug capacity decreased with increase in pile diameter, though the penetration ratio or plugging rate of piles was constant. However, the existing formulae for estimation of plug capacity give plug capacity which is constant or increased with increase in pile diameter, when penetration ratio or plugging rate of piles is equal. Thus, it is proposed that the effect of pile diameter as well as plugging rate on bearing capacity of pile must be considered in plug capacity estimation. |
| |
| Ű¿öµå |
| Scale Effect;Open-Ended Pipe;Plugging Effect;Calibration Chamber Test; |
| |
|
|
 |
|
Çѱ¹Áö¹Ý°øÇÐȸÁö:Áö¹Ý / v.12, no.2, 1996³â, pp.85-94
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-215X
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO199611920446457)
¾ð¾î : Çѱ¹¾î |
|
| ³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø |
|
|
|
|
|
|