Çѱ¹Áö¹Ý°øÇÐȸ / v.13, no.4, 1997³â, pp.5-12
Æó±â¹° ¸Å¸³ÀåÀÇ Â÷¼öÀç ¹× º¹ÅäÀç·Î¼­ Çϼö ½½·¯Áö ÀçȰ¿ë
( Reuse of Water Treatment Sludge as Liner and Cover Materials in Waste Landfills )
ÀÌ¿ë¼ö;Á¤ÇÏÀÍ; Á¤È¸¿ø, Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø, Áö¹Ý¿¬±¸½Ç;Á¤È¸¿ø, Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø, Áö¹Ý¿¬±¸½Ç;
 
ÃÊ ·Ï
ÇöÀç, Çϼö ½½·¯Áö°¡ ¸Å¸³Àå¿¡ ÁÖ·Î ´Ü¼ø ¸Å¸³µÇ°í Àִµ¥, À̸¦ Æó±â¹° ¸Å¸³ÀåÀÇ Â÷¼öÀç ¶Ç´Â º¹ÅäÀç·Î Ȱ¿ëÇÑ´Ù¸é »ê¾÷ºÎ»ê¹°ÀÇ ÀçȰ¿ëÀ̶ó´Â Ãø¸é¿¡¼­ Å« ÀÕÁ¡ÀÌ ÀÖÀ» °ÍÀÌ´Ù. À̸¦ À§ÇÏ¿© º» ³í¹®¿¡¼­ Çϼö ½½·¯Áö¿¡ ´ëÇÑ ´ÙÁü, °­µµ, Åõ¼ö, È­ÇйÝÀÀ¼º ¹× ¿ëÃâ½ÃÇè µîÀ» ½Ç½ÃÇÏ¿© ¸Å¸³ÀåÀÇ º¹ÅäÀç ¶Ç´Â Â÷¼öÀç·Î¼­ÀÇ È°¿ë¼ºÀ» °ËÅäÇÏ¿´´Ù. ½ÇÇè°á°ú, Çϼö½½·¯Áö È¥ÇÕÀç´Â º¥Å䳪ÀÌ Æ®ÀÇ Ã·°¡·®ÀÌ Áõ°¡ÇÔ¿¡ µû¶ó ÃÖ´ë°ÇÁ¶¹Ðµµ´Â Áõ°¡Çϰí ÃÖÀûÇÔ¼öºñ´Â °¨¼ÒÇÏ´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù. Çϼö½½·¯Áö È¥ÇÕÀçÀÇ °­µµ´Â º¥Å䳪ÀÌÆ®ÀÇ Ã·°¡·®À̳ª °æ°ú½Ã°£¿¡ µû¶ó Áõ°¨È¿°ú°¡ Å©°Ô ³ªÅ¸³ªÁö ¾Ê¾Ò´Ù. º¥Å䳪ÀÌÆ®ÀÇ Ã·°¡·®ÀÌ Áõ°¡ÇÔ¿¡ µû¶ó ±×¸®°í ½Ã°£ÀÌ °æ°úÇÔ¿¡ µû¶ó Åõ¼ö°è¼ö´Â °¨¼ÒÇÏ¿´À¸¸ç Åõ¼ö°è¼ö°¡ 1x10-7cm/sec°¡ µÇ±â À§ÇÑ º¥Å䳪ÀÌÆ®ÀÇ Ã·°¡·®Àº ¾à 40%Á¤µµ·Î ³ªÅ¸³µÀ¸¸ç. ÀÌ´Â Â÷¼öÀç·Î¼­ Çϼö½½·¯Áö¸¦ Ȱ¿ëÇÑ´Ù¸é º¥Å䳪ÀÌÆ® ÷°¡·®À» 40%ÀÌ»óÀ» ¿ä±¸Çϸç, ¹Ý¸é º¹ÅäÀç·Î Ȱ¿ëÇÑ´Ù¸é º¥Å䳪ÀÌÆ® ÷°¡·®ÀÌ 20%À̳»ÀÓÀ» ¾Ë ¼öÀÖ´Ù. Çϼö½½·¯Áö È¥ÇÕÀçÀÇ Ä§Ãâ¼ö¿Í ¹ÝÀÀ¼º¿¡ ÀÇÇÑ Åõ¼öƯ¼º º¯È­´Â ¹Ì¾àÇÑ °ÍÀ¸·Î ³ªÅ¸³µ´Ù.
The potentiality of water treatment sludge as the alternative liner and cover materials in landfills is investigated. A series of tests were performed on sludge admixtures to examine their compaction, compressive strength, leaching, hydraulic conductivity characterisit its and the compatibility with representative leachate within landfills. Results from the tests show that low hydraulic conductivity can berachieved with sufficient stabilizer contents and curing. It is recognized that the hydrauac conductivity decreases with increasing bentonite content and the percentage of bentonite needed to make the hydrauic conductivity below 1$ imes$10-7cm/ sec was 40% for water treatment sludge. It was found that the effect of the municipal waste leachate on the hydraulic conductivity of the admixtures is negligible.
 
Ű¿öµå
Water treatment sluge;Cover material;Waste landfills;Liner;
 