Çѱ¹Áö¹Ý°øÇÐȸ / v.13, no.4, 1997³â, pp.25-36
»õ·Î¿î ¸ÅÀÔ¸»¶Ò °ø¹ýÀÇ ÁöÁö·Â Ư¼º
( Characteristics of the Bearing Capacity for New Auger-Drilled Piles )
¹é±ÔÈ£; Á¤È¸¿ø, (ÁÖ)½º¸¶ÅØ¿£Áö´Ï¾î¸µ ÀÌ»ç;
 
ÃÊ ·Ï
±âÁ¸ÀÇ ¸ÅÀÔ¸»¶Ò°ø¹ýÀÌ °®°í ÀÖ´Â ¹®Á¦µé, Áï ÁöÁö·ÂÀÇ ¾àÈ­¿Í ¼ÒÀ½ Áøµ¿ÀÇ ¹ß»ýÀ» ÇØ°áÇϱâ À§ÇÏ¿© ³ª¼±µ¹±âÇü ¸ÅÀÔ¸»¶Ò°ø¹ý°ú ¼±´ÜÈ®´ëÇü ¸ÅÀÔ¸»¶Ò°ø¹ýÀ» °³¹ßÇÏ¿´´Ù. ÀÌµé °ø¹ýÀÇ ½Ã°ø¼º°ú ÁöÁö·Â Áõ´ëÈ¿°ú¸¦ ¾Ë¾Æº¸±â À§ÇÏ¿© ÇöÀå½ÃÇèÀ» ½Ç½ÃÇÏ¿´´Ù. ½ÃÇè°á°ú ±ØÇÑÁöÁö·ÂÀº ¸»¶Ò¿¡ ¼ºÇüµÈ µ¹±â¿¡ ÀÇÇÑ Áָ鸶Âû·ÂÀÇ Áõ°¡·Î ÀÎÇÏ¿© ħ¼³¹æ½Äº¸´Ù ¾à 44%Áõ°¡ÇÏ¿´À¸¸ç, Áָ鸶Âû·ÂÀº µ¹±âÀÇ Çü»ó°ú µ¹±â°£ÀÇ °£°Ý¿¡ ÀÇÇÏ¿© ¿µÇâÀ» ¹Þ´Â °ÍÀ¸·Î ¹àÇôÁ³´Ù. ±×¸®°í ÀüüÁöÁö·Â¿¡¼­ Áָ鸶Âû·ÂÀÌ Â÷ÁöÇÏ´Â ºñÀ²Àº ħ¼³¹æ½ÄÀÇ °æ¿ì°¡ 74~80%ÀÌ°í ³ª¼±µ¹±â Çü°ú ¼±´ÜÈ®´ëÇüÀÇ °æ¿ì°¡ 81~86% ¸ÅÀÔ¸»¶ÒÀÇ ÁöÁö·Â¿¡¼­ ¼±´ÜÁöÁö·ÂÀÌ Â÷ÁöÇÏ´Â ºñÀ²Àº ¸Å¿ì ÀÛ¾Ò´Ù. ¶ÇÇÑ µ¿ÀÏ ÇÏÁß¿¡ ´ëÇÑ Ä§ÇÏ·®À» ºñ±³ÇÑ °á°ú ħ¼³¹æ½Äº¸´Ù´Â ³ª¼±µ¹±âÇü°ú ¼±´ÜÈ®´ëÇü ¸ÅÀÔ¸»¶ÒÀÇ Ä§ÇÏ·®ÀÌ ÀÛ°Ô ÃøÁ¤µÇ¾ú´Ù.
To increase the bearing capacity of existing auger-drilled piles and decrease the noise and vibration during the installation of the piles, Spirally-reamed and Under-reamed auger trilled piling methods were developed. Field tests were performed to verify the inurement degree of bearing capacity and the constructional possibility of the new augerdrilled piling methods. The test results showed that the bearing capacity of the new augertrilled piles was fairly improved by the grooves of piles, and the skin friction was affected by the groove height and spacing between grooves. It was found that the skin friction takes the great part of total bearing capacity in auger drilled Biles, i.e. 74~80% in case of the existing methods and 81~86% in case of these methods. Moreover, the settlement of spirally-reamed and under reamed piles was smaller than that of the existing augerdrilled pile for the same loading state.
 
Ű¿öµå
Spirally-reamed;Under-reamed;Auger-drilled pile;Pile load test;Field test;
 
Çѱ¹Áö¹Ý°øÇÐȸÁö:Áö¹Ý / v.13, no.4, 1997³â, pp.25-36