Çѱ¹Áö¹Ý°øÇÐȸ / v.25, no.10, 2009³â, pp.5-15
½Ç±Ô¸ð ÇöÀå½ÃÇèÀ» ÅëÇÑ ºÎÂøÇü ¾Ï¹Ý¾ÞÄ¿ÀÇ ÀιßÀúÇ×·Â Æò°¡
( Uplift Capacity Estimation of Bond-type Rock Anchors Based on Full Scale Field Tests )
±è´ëÈ«;¿À±â´ë; Çѱ¹Àü·Â°ø»ç Àü·Â¿¬±¸¿ø;Çѱ¹Àü·Â°ø»ç Àü·Â¿¬±¸¿ø;
 
ÃÊ ·Ï
º» ³í¹®¿¡¼­´Â ¿Áõ ¹× â³çÁö¿ª¿¡¼­ ÃÑ 24ȸ ¼öÇàÇÑ ¾Ï¹Ý¾ÞÄ¿ ÇöÀåÀι߽ÃÇèÀÇ °á°ú¸¦ ³ªÅ¸³»¾ú´Ù. ½ÃÇè¾ÞÄ¿ÀÇ Á¤Âø±íÀÌ´Â 1~6m·Î ¼­·Î´Ù¸¥ ¾Ï¹Ý³»¿¡ ¼³Ä¡ÇÏ¿´´Ù. ¾ÞÄ¿ÀÇ ´ëºÎºÐÀº °í°­µµ ÀÌÇüö±ÙÀÎ SD40-D51mm¸¦ »ç¿ëÇÔÀ¸·Î½á ´Ù¸¥ ÆÄ±«°¡ ÀϾ±â Àü¿¡ ¾Ï¹ÝÆÄ±«°¡ ¸ÕÀú ÀϾµµ·Ï À¯µµÇÏ¿© ¾Ï¹ÝÀÇ ÀιßÀúÇ×·ÂÀ» ÆÄ¾ÇÇϰíÀÚ ÇÏ¿´À¸¸ç, ÀϺο¡¼­´Â SD40-D32mm¾ÞÄ¿¸¦ ¼³Ä¡ÇÏ¿© ¾ÞÄ¿ÀÇ ÆÄ±«µµ ¾Æ¿ï·¯ »ìÆìº¸¾Ò´Ù. ¸¹Àº ½ÃÇè¿¡¼­ ÆÄ±«´Â Ç׺¹¿¡ À̸£´Â ±ØÇÑÇÏÁß±îÁö °üÂûÇÒ ¼ö ÀÖ¾úÀ¸¸ç, ¾Ï¹ÝÆÄ±«Çü»óÀº ¾Ï¹ÝÀÌ µé¾î¿Ã·ÁÁö¸é¼­ ¹æ»ç»óÀ¸·Î ±Õ¿­ÀÌ ¹ß´ÞÇÏ´Â ÇüŸ¦ ³ªÅ¸³»¾ú´Ù. ¶ÇÇÑ ½Ã¸àÆ®±×¶ó¿ìÆ®¿Í ÅÙ´ø»çÀÌÀÇ ºÎÂø°­µµ¸¦ Æò°¡ÇϰíÀÚ ¹æ½Ä½¬À̽º°¡ ¼³Ä¡µÈ ¾ÞÄ¿¿¡ ´ëÇØ ½Ç³»½ÇÇèÀ» ½Ç½ÃÇÏ¿´´Ù. ½ÇÇè°á°ú ÅÙ´ø-±×¶ó¿ìÆ® »çÀÌÀÇ ºÎÂø°­µµ´Â ±×¶ó¿ìÆ® ÀÏÃà¾ÐÃà°­µµÀÇ 18~25%·Î ³ªÅ¸³µÀ¸¸ç, ¹æ½Ä½¬À̽º¿¡ ÀÇÇÑ ºÎÂø·Â °¨¼Ò´Â ¹«½ÃÇÒ ¼ö ÀÖÀ» Á¤µµ·Î ÀÛ°Ô ³ªÅ¸³µ´Ù.
This paper presents the results of full-scale uplift load tests performed on 24 passive anchors grouted to various lengths at Okchun and Changnyong site. Rock anchors were installed over a wide range of rock types and qualities with a fixed anchored depth of 1~6 m. The majority of installations used D51 mm high grade steel rebar to induce rock failure prior to rod failure. However, a few installations included the use of D32 mm rebar at relatively deeper anchored depth so as to induce rod failure. In many tests, rock failure was reached and the ultimate loads were recorded along with observations of the shape and extent of the failure surface. In addition to field tests, laboratory pullout tests were conducted to determine bond strength and bond stress-shear slip relation at the tendon/grout interface when a corrosion protection sheath is installed in the cement-based grout. The test results show that the ultimate tendon-grout bond strength is measured from 18~25% of unconfined compressive strength of grout. One of the important results from these tests is that the measured strains along the corrosion protection sheath were so small that practically the reduction of bond strength by the presence of sheath would be negligible.
 
Ű¿öµå
Bond strength;Failure mechanism;Rock anchor;Rock mass;Transmission tower foundation;Uplift capacity;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.25, no.10, 2009³â, pp.5-15