¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹Áö¹Ý°øÇÐȸ / v.26, no.6, 2010³â, pp.29-38
±âÃÊ Æø ¹× ¾Ï¹ÝÃþÀÇ ¿µÇâÀ» °í·ÁÇÑ ¸¶ÀÌÅ©·ÎÆÄÀÏ ¼³Ä¡¹æ¾È¿¡ °üÇÑ ¿¬±¸
( The Effects of the Breadth of Foundation and Rock Layer on the Installation Method of Micro-piles )
ȲÅÂÇö;±èÁöÈ£;±Ç¿À¿±; °Ç±¹´ë ´ëÇпø Åä¸ñ°øÇаú;(ÁÖ)½îÀÏÅØÄÚ¸®¾Æ;°Ç±¹´ë °ø°ú´ëÇÐ Åä¸ñ°øÇаú;
 
ÃÊ ·Ï
¸¶ÀÌÅ©·ÎÆÄÀÏÀº ±âÁ¸ ¾èÀº ±âÃÊÀÇ ÁöÁö·Â Áõ°¡ ¶Ç´Â ħÇÏ ¾ïÁ¦ ¸ñÀûÀ¸·Î ÁÖ·Î »ç¿ëµÇ¾î ¿Ô´Ù. ÃÖ±Ù¿¡´Â ÀÌ·¯ÇÑ ¸ñÀû¿¡¸¸ ±¹ÇѵÇÁö ¾Ê°í, ±âÁ¸ ÆÄÀϰú À¯»çÇÑ ÁöÁöÆÄÀÏ, »ç¸éÀÇ ¾ÈÁ¤À» À§ÇÑ ¾ïÁö¸»¶Ò, ¿Ëº®ÀÇ Àü´ÜŰ µî°ú °°Àº »ç¿ë ¸ñÀû¿¡ µû¶ó ´Ù¾çÇÏ°Ô ÇöÀå¿¡¼­ Ȱ¿ëµÇ°í ÀÖ´Ù. ¸¶ÀÌÅ©·ÎÆÄÀÏÀÇ È°¿ë ºóµµ°¡ Á¡Â÷ Áõ°¡ÇÔ¿¡ µû¶ó ¸î¸î ¿¬±¸ÀÚµéÀÌ ÇöÀå ½ÃÇè ¶Ç´Â ¸ðÇü½ÃÇèÀ» ÅëÇØ ÃÖÀûÀÇ ¼³Ä¡ ¹æ¹ý¿¡ ´ëÇØ ¿¬±¸¸¦ Çϰí ÀÖ´Ù. ±×·¯³ª ÁøÇàµÇ°í ÀÖ´Â ¿¬±¸´Â ´ëºÎºÐÀÌ Åä»ç ¶Ç´Â Á¡ÅäÁö¹ÝÀ» ´ë»óÀ¸·Î ÇÑ °ÍÀÌ´Ù. ÇöÀåÁö¹ÝÀº ´ÜÀÏ Åä»ç ¶Ç´Â Á¡Åä Áö¹Ý¸¸À¸·Î ±¸¼ºµÈ °æ¿ì°¡ µå¹°´Ù. ¶ÇÇÑ ¾Ï¹ÝÃþÀÌ Á¸ÀçÇÏ´Â Áö¹Ý¿¡¼­´Â ¾Ï¹ÝÃþÀÇ À§Ä¡¿¡ µû¶ó ÆÄÀÏ ±æÀ̰¡ °áÁ¤µÇ¸ç, °áÁ¤µÈ ÆÄÀϱæÀÌ¿¡ µû¶ó ÆÄÀÏ °­¼ºÀÌ ´Þ¶óÁú ¼ö ÀÖÀ¸¹Ç·Î ÀÌ¿¡ ´ëÇÑ ¿¬±¸°¡ ¿ä±¸µÈ´Ù. º» ¿¬±¸¿¡¼­´Â ¾Ï¹ÝÃþÀÇ À§Ä¡¿¡ µû¸¥ ¸¶ÀÌÅ©·ÎÆÄÀÏÀÇ ÃÖÀû ¼³Ä¡¹æ¾ÈÀ» ±Ô¸íÇϱâ À§ÇØ ¸ðÇü½ÃÇèÀ» ½Ç½ÃÇÏ¿´´Ù. ¿¬±¸ °á°ú, ÆÄÀÏ °­¼º°ú °ü·ÃµÈ ÆÄÀÏ ±æÀ̺ñ(L/d)°¡ 50ÀÌÇÏÀÎ °æ¿ì¿¡´Â ¾Ï¹ÝÃþ À§Ä¡¿Í °ü°è¾øÀÌ ¼öÁ÷À¸·Î ¼³Ä¡ÇÏ´Â °ÍÀÌ È¿°úÀûÀÎ °ÍÀ¸·Î ³ªÅ¸³µ´Ù. ¶ÇÇÑ ÆÄÀÏ ±æÀ̺ñ°¡ 50À» ÃʰúÇϰí, ¾Ï¹ÝÃþÀ§Ä¡°¡ Áö¹Ý ÆÄ±«±íÀ̺¸´Ù ±íÀ¸¸é, ÆÄÀÏÀ» °æ»çÁö°Ô ¼³Ä¡ÇÏ´Â °ÍÀÌ ´õ È¿°úÀûÀÎ °ÍÀ¸·Î ³ªÅ¸³µ´Ù.
Micro-piles have been used to increase the bearing capacity or to restrain settlement of existing shallow foundation. Recently, micro-piles are used to support the shallow foundation, to stabilize the slope and to resist the sliding of retaining wall. Using the micro-piles in geotechnical engineering, some investigators have studied the effective installing method by model test or field test. But most of previous studies are chiefly focused on the micro-piles in sand or clay layer. If a rock layer exists in soil, the installing length of micro-piles may be determined by the depth of rock layer. In this case, the stiffness of pile may be changed by the installing length of pile, and so the installing method has to be altered by the changed stiffness of pile. Model tests have been conducted to study the installation method of micro-pile in soil with rock layer. As a result, when the ratio of length of pile is below 50 ($L/d{leq}50$), installing of micro-piles in vertical position is effective regardless of the depth of rock layer. If the depth of rock layer is deeper than soil failure zone and the ratio of the length of pile exceeds 50 (L/d>50), installing of the micro-piles in sloped position is effective.
 
Ű¿öµå
Micro-pile;Model test;Soils with rock layer;Ratio of length of pile;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.26, no.6, 2010³â, pp.29-38
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO201030853095381)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿