Çѱ¹Áö¹Ý°øÇÐȸ / v.19, no.6, 2003³â, pp.169-179
|
ÇÇ¿¡Á¶ ÄÜ ½ÃÇèÀ» ÀÌ¿ëÇÑ Á¡¼ºÅäÀÇ ºñ¹è¼ö °µµ ÃßÁ¤
( Estimation of Undrained Shear Strength Using Piezocone Test ) |
| ¹Ú¿ë¿ø;±¸³²½Ç;ÀÌ»óÀÍ; ¸íÁö´ëÇб³ Åä¸ñȯ°æ°øÇаú;¸íÁö´ëÇб³ Åä¸ñ°øÇаú;¢ß»óÁö¿£Áö´Ï¾î¸µ;
|
|
|
 |
|
| |
| ÃÊ ·Ï |
| ¿¬¾àÁö¹Ý¿¡ ÃàÁ¶µÇ´Â ±¸Á¶¹° ¼³°è¿¡ ¸Å¿ì Áß¿äÇÑ Áö¹Ý Ư¼ºÄ¡ÀÎ Á¡ÅäÁö¹ÝÀÇ ºñ¹è¼ö Àü´Ü°µµ¸¦ ±íÀÌ¿¡ µû¶ó ¿¬¼ÓÀûÀ¸·Î ÃøÁ¤ÇÒ ¼ö ÀÖ´Â ÇöÀå ¿øÀ§Ä¡ ½ÃÇè¹ýÀ¸·Î¼ ÇÇ¿¡Á¶ ÄÜÀÇ È°¿ëµµ°¡ Á¡Á¡ ³ô¾ÆÁö°í ÀÖ´Ù. ÇÇ¿¡Á¶ ÄÜ ½ÃÇèÀ¸·Î ÃßÁ¤µÇ´Â ºñ¹è¼ö °µµÀÇ ½Å·Ú¼ºÀº ÀÌ¿¡ Àû¿ëµÇ´Â ÄÜ °è¼ö °ªÀÇ ½Å·Ú¼º¿¡ Å©°Ô ÀÇÁ¸ÇÑ´Ù. ÄÜ °è¼ö¿¡ ´ëÇÑ ¿©·¯ ¿¬±¸ÀÚµéÀÇ Á¦¾ÈÀÌ ¿ì¸®ÀÇ ½ÇÁ¤¿¡ ¸Â´ÂÁö °ËÁõÇϰí Á¡ÅäÁö¹ÝÀÇ Æ¯¼º¿¡ µû¸¥ ÄÜ °è¼ö °ªÀÇ º¯È Ư¼ºÀ» ÆÄ¾ÇÇÏ¿© ÄÜ °è¼ö ¼±Á¤¿¡ ´ëÇÑ ÇÕ¸®ÀûÀÎ ±âÁØÀ» ¸¶·ÃÇÏ´Â °ÍÀÌ ÀÌ ¿¬±¸ÀÇ ¸ñÀûÀÌ´Ù. ÀÌ ¿¬±¸´Â °æ³² ¾ç»ê¹°±Ý Áö¿ªÀÇ ÇØ¼ºÁ¡ÅäÃþÀ» ´ë»óÀ¸·Î ÇÇ¿¡Á¶ ÄÜ ½ÃÇè°ú ºñ±³¶õ ½Ã·á¿¡ ´ëÇÑ ½Ç³» Àü´Ü°µµ½ÃÇè(ÀÏÃà¾ÐÃà½ÃÇè, ºñ¾Ð¹Ð ºñ¹è¼ö »ïÃà¾ÐÃà½ÃÇè)°ú ¾Ð¹Ð½ÃÇèÀ» ½Ç½ÃÇÏ¿´´Ù. ½ÃÇè °á°ú¸¦ ÀÌ¿ëÇÏ¿© ÄÜ °è¼ö¿Í Á¡ÅäÀÇ ¿©·¯ ¿ªÇÐÀû Ư¼ºÄ¡(ºñ¹è¼ö Àü´Ü°µµ, ¼±Çà¾Ð¹Ð¾Ð·Â, ¼Ò¼ºÁö¼ö, °£±Ø¼ö¾Ðºñ, °¼ºÁö¼ö, ¸¶Âûºñ)ÀÇ °ü°è¸¦ °íÂûÇÏ¿© ÄÜ °è¼ö °ªÀÇ ÇÕ¸®Àû ¼±Á¤À» À§ÇÑ ±âÁØÀ» ¸¶·ÃÇϰíÀÚ ÇÏ¿´´Ù. ¿¬±¸ °á°ú·ÎºÎÅÍ ¾òÀº °á·ÐÀ¸·Î¼´Â, »ó°ü°ü°è°¡ ºñ±³Àû ³ôÀº Ư¼ºÄ¡ÀÇ Â¦Àº ºñ¹è¼ö Àü´Ü°µµ¿Í ÄÜ °è¼ö$(N_{kt}, N_{ke}, N_{Delta u})$, ¼±Çà¾Ð¹Ð¾Ð·Â°ú $(N_{kt}, N_{ke})$, °£±Ø¼ö¾Ðºñ(B$_{q}$ )¿Í $(N_{ke}, N_{Delta u})$À̾ú°í ¼±Çà¾Ð¹Ð¾Ð·Â°ú $(N_{Delta u}), B_q¿Í (N_{kt})$´Â »ó°ü °ü°è°¡ ³ªÅ¸³ªÁö ¾Ê¾ÒÀ¸¸ç, ¼Ò¼ºÁö¼ö, °¼ºÁö¼ö, ±×¸®°í ¸¶Âûºñµµ ÄÜ °è¼ö¿Í »ó°ü °ü°è°¡ ¾ø´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù. ¶ÇÇÑ, ºñ¾Ð¹Ð ºñ¹è¼ö(UU) »ïÃà¾ÐÃà½ÃÇèÀ¸·Î ±¸ÇÑ Á¡ÅäÀÇ ºñ¹è¼ö Àü´Ü°µµ¸¦ ±âÁØÀ¸·Î ÇÒ ¶§, ¿©·¯ Á¦¾ÈÀÚµéÀÌ Á¦¾ÈÇÑ ÇÇ¿¡Á¶ ÄÜ ½ÃÇè°á°ú¸¦ ÀÌ¿ëÇÑ ºñ¹è¼ö Àü´Ü°µµ ÃßÁ¤¿¡¼ $(N_{Delta u})$°¡ ´Ù¸¥ µÎ°³ÀÇ ÄÜ °è¼öº¸´Ù ¼±Çà¾Ð¹Ð¾Ð·ÂÀÇ Å©±â¿¡ »ó°ü¾øÀÌ º¯ÈÆø, Ç¥ÁØÆíÂ÷ ¹× ºÐ»êµµ°¡ ¸ðµÎ À۾Ƽ ½Å·Ú¼ºÀÌ °¡Àå ³ô°Ô ³ªÅ¸³µ´Ù. |
|
| Undrained shear strength of clay deposit is one of the most important properties in the design of geotechnical structures. The use of piezocone test is rapidly growing due to its merit that can measure the in-situ undrained shear strength continuously with less error. The reliability of the shear strength from piezocone test depends upon the cone factor applied. Many researchers have suggested different ranges of values for the factors. This study performs to find out the validity of the suggested values in Korea and their charateristics related to the mechanical properties of clay. Piezocone tests were performed at the site of pilot project of ground improvement at Yangsan-Mulgeum Gyeongnam to investigate the charateristics of piezocone factors. The piezocone fators$(N_{kt}, N_{ke}, N_{Delta u})$ based on the undrained shear strength from quick triaxial compression test are generally within the suggested range. And there appears considerable relations between undrained shear strength and $(N_{kt}, N_{ke}, N_{Delta u})$ and between preconsolidation pressure and $(N_{kt}, N_{ke})$, while plasticity index, rigidity index and friction ratio do not show any relations with cone factors. The results also reveal that factor $(N_{Delta u})$ shows higher reliability than factors $(N_{kt} and N_{ke})$, which show smaller standard deviation, breadth of change and scattering. |
| |
| Ű¿öµå |
| Cone factor;Piezocone test;Undrained shear strength; |
| |
|
|
 |
|
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.19, no.6, 2003³â, pp.169-179
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200311922147957)
¾ð¾î : Çѱ¹¾î |
|
| ³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø |
|
|
|
|
|
|