Çѱ¹Áö¹Ý°øÇÐȸ / v.19, no.6, 2003³â, pp.351-361
µµ½ÉÁö È븷ÀÌ ±¼Âø½Ã ÀÎÁ¢±¸Á¶¹°ÀÇ ¼Õ»ó Æò°¡¿¬±¸
( The Evaluation of Damage Behaviour of Adjacent Structures in Urban Excavation )
±èÇй®;ȲÀǼ®; ´Ü±¹´ëÇб³ Åä¸ñȯ°æ°øÇаú;´Ü±¹´ëÇб³ Åä¸ñȯ°æ°øÇаú;
 
ÃÊ ·Ï
È븷ÀÌ Áö¹Ý±¼Âø½Ã ÀÎÁ¢ ±¸Á¶¹°ÀÇ ¼Õ»ó¸ÞÄ«´ÏÁòÀ» ±Ô¸íÇϱâ À§ÇÏ¿© 1.844m(±æÀÌ)$ imes$0.6m(³ôÀÌ)ÀÎ ¸ðÇüÁ¶Àûº®Ã¼¸¦ ½ÇÁ¦ÀÇ 1/10ÀÇ ½ºÄÉÀÏ·Î ¸ðÇüÈ­ÇÏ¿´´Ù. Peck(1969) ¹× O'Rourkeµî(1976)ÀÌ Á¦¾ÈÇÑ Áö¹ÝħÇÏ·®ÀÌ 6´Ü°è¿¡ °ÉÃÄ ¸ðÇü½ÇÇè¿¡ Àû¿ëµÇ¾ú´Ù. Peck(1969)°ú O'Rourkeµî(1976)ÀÇ ¹æ¹ýÀ» Àû¿ëÇÑ ¸ðÇü½ÇÇè°á°ú, O'Rourkeµî(1976)¿¡ ÀÇÇÑ Á¶Àûº®Ã¼ÀÇ °¢º¯À§´Â Peck(1969)ÀÇ °¢º¯À§¿¡ ºñÇØ 21% Å©°Ô ³ªÅ¸³µÀ¸¸ç, ¼öÆòº¯À§ ¶ÇÇÑ Peck(1969)¿¡ ÀÇÇÑ °ªº¸´Ù 24% Å©°Ô ³ªÅ¸³µ´Ù. O'Rourkeµî(1976)ÀÇ Ä§ÇÏ·®ÀÌ Àû¿ëµÈ °æ¿ìÀÇ °Ç¹°¼Õ»ó Á¤µµ¸¦ ¼Õ»óµµÇ¥(Boscardin & Cording,1989)¿¡ Àû¿ëÇÑ °á°ú Peck(1969) ¹æ¹ý¿¡ ÀÇÇØ ¾òÀº ¼Õ»ó¼öÁØ¿¡ ºñÇØ º¸´Ù ½É°¢ÇÑ ¼Õ»ó¼öÁØÀÇ °á°ú°¡ ³ªÅ¸³µ´Ù. ¶ÇÇÑ, ±¸Á¶¹°ÀÇ °­¼º ¹× ±¸Á¶¹°°ú Áö¹ÝÀÇ interface °¡ ±¸Á¶¹° ¼Õ»óÆò°¡½Ã Áß¿äÇÑ ÀÎÀÚ·Î½á °í·ÁµÇ¾î¾ß ÇÔÀ» È®ÀÎÇÒ ¼ö ÀÖ¾ú´Ù.
Brick wall models with window opening, length 1.844m $ imes$ height 0.6m, representing 2-story building was constructed on a scale of 1/10 of actual size of brick building for the investigation of damage mechanism. Six settlement troughs presenting six stages of excavation were simulated by Peck(1969) and O'Rourke et al.(1976) methods. The results from the model tests using Peck(1969) and O'Rourke et al.(1976) method indicated that angular distortion of brick wall by O'Rourke et at. method was 21% greater than that of Peck method. Horizontal displacement by O'Rourke et al.(1976) was 24% greater than that of Peck. When the degree of building damage for the O'Rourke et al. method of settlement trough is plotted on the damage level graph(Boscardin & Cording, 1989), damage level becomes much more severe than the level obtained by peck's method. Also, building stiffness and soil-structure interface are considered important factors of expressing building damage.
 
Ű¿öµå
Angular distortion;Damage level;Horizontal strain;Masonry building damage;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.19, no.6, 2003³â, pp.351-361