Çѱ¹Áö¹Ý°øÇÐȸ / v.20, no.2, 2004³â, pp.27-36
|
¿µ±¸ Áö¹Ý¾ÞÄ¿¿¡ ´ëÇÑ ºÎ½ÄÀÇ ¿µÇâ Æò°¡
( Evaluation of Corrosion Effects on Permanent Ground Anchors ) |
| ;; ;;
|
|
|
 |
|
| |
| ÃÊ ·Ï |
| ±Ø¼ºÀúÇ× °èÃø¹ý°ú Àü±âÈÇÐ ÀÓÇÇ´ø½º ºÐ±¤ÇÐÀ» ÀÌ¿ëÇÏ¿© ¿µ±¸Àû Áö¹Ý ¾ÞÄ¿ÀÇ ºÎ½ÄÀ²À» °èÃøÇÏ´Â ÀýÂ÷¸¦ Á¦½ÃÇÏ¿´´Ù. ±Ø¼ºÀúÇ× °èÃø¹ýÀ» ÀÌ¿ëÇÏ¿© ´ëÇ¥Áö¹ÝÀÇ Á¾·ù¿Í öÀÇ ºÎ½Ä·ü¿¡ °üÇÑ Æ¯¼º°ü°è¸¦ µµÃâÇÏ¿´°í, Àü±âÈÇÐ ÀÓÇÇ´ø½º ºÐ±¤ÇÐÀ» ÀÌ¿ëÇÏ¿© ½Ã°£ÀÇÁ¸ ºÎ½Ä ¹ÝÀÀ°ú ´Ù¾çÇÑ Á¾·ùÀÇ ÄÚ¿ìÆÃ ½Ã½ºÅÛÀÇ Æò°¡, ±×¸®°í ½Ã¸àÆ® ±×¶ó¿ìÆÃÀÌ ºÎ½Ä¿¡ ¹ÌÄ¡´Â ¿µÇâ¿¡ ´ëÇÏ¿© °¢°¢ Æò°¡ÇÏ¿´´Ù. ½ÇÇè °á°ú Á¡¼ºÅä¿Í »çÁúÅäÀÇ pH Áö¼ö°¡ 5ÀÌÇÏÀÎ °æ¿ì ºÎ½Ä¹ß»ýÀÌ ¿ëÀÌÇÑ Áö¹ÝÀ¸·Î¼ ¿µ±¸Àû Áö¹Ý ¾ÞÄ¿ÀÇ ºÎ½Ä¹ÝÀÀ¿¡ ½É°¢ÇÑ ¿µÇâÀ» ¹ÌÄ¡¸®¶ó ÆÇ´ÜµÈ´Ù. ¶ÇÇÑ Áß¼º ¶Ç´Â ¾ËÄ«¸®¼ºÀÇ Áö¹ÝÀº ºÎ½ÄÁøÇàÀÌ °üÂûµÇÁö ¾Ê¾ÒÀ¸¸ç ºÎ½Ä·üÀº pHÁö¼ö¿¡ °ü°è¾øÀÌ ÀÏÁ¤ÇÑ °á°ú¸¦ º¸¿´´Ù. Æ÷¼³¸° Á¡¼ºÅäÀÇ °æ¿ì pHÁö¼öÀÇ º¯È°¡ öÀÇ ºÎ½Ä¿¡ ¸Å¿ì ³·Àº ¿µÇâÀ» ¹ÌÃÆ´Ù. ÇÑÆí ½Ã¸àÆ® ±×¶ó¿ìÆÃÀÇ »ç¿ëÀº öÀÇ ºÎ½ÄÀ²À» ¾à 0.003-0.0lmm/y Á¤µµ·Î ³·Ãâ ¼ö ÀÖ¾úÀ¸¸ç ¿¡Æø½Ã È¥ÇÕ ÄÚ¿ìÆÃÀÇ °æ¿ìµµ ºÎ½ÄÀÇ ¿µÇâÀ» ¹ÞÁö¾Ê°í ¿ø »óŸ¦ À¯ÁöÇÒ ¼ö ÀÖ¾î ¸Å¿ì È¿°úÀûÀ¸·Î ºÎ½ÄÈ¿°ú¸¦ °¨¼Ò½Ãų ¼ö ÀÖ¾ú´Ù. |
|
| The corrosion rate measurement procedure for the permanent ground anchors using polarization resistance measurements and electrochemical impedance spectroscopy is presented in this paper. The polarization resistance measurements were used to determine the correlation between corrosion rate in the steel and soil characteristics. The electrochemical impedance spectroscopy was used to predict the time dependent corrosion reaction and evaluate the different type of coating systems and the effect of cement grouting on the corrosion attack under various conditions. The results indicate that a low pH soil is a good indicator of a corrosive soil. The low pH soil condition (<5) in both clay and sand has a significant effect on the corrosion reaction of steel members in permanent found anchors. In the case of neutral and alkaline conditions beyond pH 6 in clay and sand, no consistent acceleration of corrosion was measured and the corrosion rate was constant regardless of variations of soil pH levels. Laboratory test data for porcelain clay indicate that the change of soil pH level has a small influence on the corrosion reaction in the steel member. The use of cement footing in the bonded length is sufficient to decrease the corrosion rate to a level close to 0.003¡0.01mm/y at the end of the given period. With epoxy and fusion bonded epoxy coating, the steel specimens remained unaffected and retained the original condition. It is suggested that epoxy and fusion bonded epoxy coating can provide effective protection against corrosion for a long time even in aggressive environment. |
| |
| Ű¿öµå |
| Corrosion rate;Electrochemical impedance spectroscopy;Permanent ground anchors;Polarization resistance measurements; |
| |
|
|
 |
|
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.20, no.2, 2004³â, pp.27-36
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200411922321489)
¾ð¾î : ¿µ¾î |
|
| ³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø |
|
|
|
|
|
|