Çѱ¹Áö¹Ý°øÇÐȸ / v.21, no.2, 2005³â, pp.27-36
µµ½ÉÁö ±¼Âø¿¡ Àû¿ëµÈ IPS È븷ÀÌ ±¸Á¶¹°ÀÇ ÇöÀå°Åµ¿
( Performance of Innovative Prestressed Support Earth Retention System in Urban Excavation )
±è³«°æ;¹ÚÁ¾½Ä;ÀåÈ£ÁØ;ÇѸ¸¿±;±è¹®¿µ;±è¼ºº¸; ;;;;;;
 
ÃÊ ·Ï
º» ¿¬±¸¿¡¼­´Â µµ½ÉÁö ±¼Âø ÇöÀå¿¡ Àû¿ëµÈ IPS(Innovative Prestressed Support) È븷ÀÌ ±¸Á¶¹°ÀÇ °Åµ¿À» ÆÄ¾ÇÇÏ¿© ½Ã½ºÅÛÀÇ ¾ÈÁ¤¼ºÀ» È®ÀÎÇÏ¿´´Ù. »õ·Î¿î È븷ÀÌ Áöº¸ÀçÀÎ IPS ¶ìÀåÀº Áö¹Ý ±¼ÂøÀ¸·Î ÀÎÇÑ Åä¾ÐÀ» ÀÚüÀÇ ÈÚ°­¼ºÀ» ÀÌ¿ëÇÏ¿© ¹öÆÀº¸¿¡ Àü´ÞÇϴ Ư¡À» °¡Áö°í ÀÖ´Ù. IPS ¶ìÀåÀÇ ÈÚ°­¼ºÀº ±âÁ¸ ±¼Âø °ø¹ý¿¡ Àû¿ëµÈ ¶ìÀå¿¡ ºñÇØ ¿ùµîÇϱ⠶§¹®¿¡ IPS ¶ìÀåÀ» Ȱ¿ëÇϸé È븷ÀÌ º®Ã¼¸¦ ÁöÁöÇÏ´Â ¹öÆÀº¸ÀÇ ¼³Ä¡ °£°ÝÀ» ȹ±âÀûÀ¸·Î ¹ýÈú ¼ö ÀÖÀ¸¸ç ±¼Âø½Ã¿¡ ¹ýÀº ÀÛ¾÷ °ø°£À» Á¦°øÇÑ´Ù. ÀÌ·Î ÀÎÇØ ±¼Âø °ø»ç¿¡ »ç¿ëµÇ´Â °­°èÀÇ ¹°·®À» ÁÙÀÏ ¼ö ÀÖ´Ù. ¶ÇÇÑ IPS ¶ìÀå¿¡ °­¼±ÀÇ ÀÎÀå·ÂÀ» µµÀÔÇÏ¿© ¼±Çà ÇÏÁßÀ» °¡ÇÔÀ¸·Î½á Áö¹Ý ±¼ÂøÀ¸·Î ÀÎÇÑ È븷ÀÌ º®Ã¼ÀÇ º¯ÇüÀ» Á¦ÇÑÇÒ ¼ö ÀÖ´Ù. º» ¿¬±¸¿¡¼­´Â IPS È븷ÀÌ °ø¹ýÀ» Àû¿ëÇÑ µµ½ÉÁö ±¼Âø ÇöÀå¿¡ ½Ã°ø Àü±â°£ °èÃøÀ» ¼öÇàÇÏ¿© ±× Àû¿ë¼º°ú ¾ÈÁ¤¼ºÀ» È®ÀÎÇÏ¿´´Ù. ÇöÀå °èÃø °á°ú¸¦ ºÐ¼®ÇÏ¿© Çõ½ÅÀûÀÎ È븷ÀÌ Áöº¸ÀçÀÎ IPS ¶ìÀå°ú IPS È븷ÀÌ º®Ã¼ ±×¸®°í ÄÚ³Ê ½ºÆ®Ä£ÀÇ °Åµ¿À» ºÐ¼®ÇÏ¿´´Ù.
The performance of innovative prestressed support (IPS) earth retention system applied in urban excavation was presented and investigated. The IPS wales provide a high flexural stiffness to resist the bending by lateral earth pressure, and the IPS wales transfer lateral earth pressure to Corner struts. The IPS wale provides a larger spacing of support, economical benefit, construction easiness, good performance, and safety control. In order to investigate applicability and stability of the IPS earth retention system, the IPS system was instrumented and was monitored during construction. The IPS system applied in urban excavation functioned successfully. The results of the field instrumentation were presented. The measured performances of the IPS earth retention system were investigated and discussed.
 
Ű¿öµå
 