¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹Áö¹Ý°øÇÐȸ / v.21, no.6, 2005³â, pp.67-79
¹Ýº¹½Ä ÆòÆÇÀçÇϽÃÇèÀ» ÀÌ¿ëÇÑ ³ë»óÅäÀÇ ÇöÀå º¯Çü°è¼ö Æò°¡
( Evaluation of Field Nonlinear Modulus of Subgrnde Soils Using Repetitive Static Plate Bearing Load Test )
±èµ¿¼ö;¼­¿ø¼®;±Ç±âö; Çѱ¹°úÇбâ¼ú¿ø °Ç¼³ ¹× Ȳ°æ°øÇаú;Çѱ¹°úÇбâ¼ú¿ø °Ç¼³ ¹× Ȳ°æ°øÇаú;µ¿ÀÇ´ëÇб³ Åä¸ñ°øÇаú;
 
ÃÊ ·Ï
ÇöÀå ÆòÆÇÀçÇϽÃÇèÀº ÆòÆÇ¿¡ ÀÛ¿ëÇÏ´Â ÇÏÁß°ú º¯À§¸¦ µ¿½Ã¿¡ ÃøÁ¤Çϱ⠶§¹®¿¡ ¿ªÇÐÀûÀΠƯ¼ºÄ¡ °áÁ¤ÀÇ °¡´É¼ºÀÌ ³ôÀº ½ÃÇè¹æ¹ýÀÌ´Ù. ±×·¯³ª Áö±Ý±îÁö ÆòÆÇÀçÇϽÃÇèÀ¸·ÎºÎÅÍ ÃßÁ¤ÇÑ Åº¼º°è¼ö´Â ÀÏÁ¤ º¯À§¸¦ À¯¹ßÇÑ ÇÏÁß°­µµÇÏ¿¡¼­ÀÇ ÁöÁö·Â°è¼ö·ÎºÎÅÍ ±¸ÇÑ ÇϳªÀÇ »ó¼ö°ªÀ¸·Î¼­, ÀÌ´Â Æ÷À屸Á¶¿¡¼­ ³ë»óÀÌ °æÇèÇÏ´Â »ç¿ëÇÏÁß ´Ü°è¿¡¼­ÀÇ ´ëÇ¥ÀûÀÎ º¯ÇüƯ¼ºÄ¡·Î °áÁ¤Çϱ⿡´Â ¾î·Á¿òÀÌ ÀÖ´Ù. Æ÷Àå¼³°è½Ã »ç¿ëµÇ´Â ȸº¹Åº¼º°è¼ö °³³äÀÇ º¯Çü°è¼ö´Â Áß°£º¯Çü·ü$(0.01%sim0.1%)$ ¿µ¿ª¿¡¼­ÀÇ °ªÀ¸·Î¼­, ÇöÀå ³ë»óÅäÀÇ °æ¿ì¿¡µµ ÀÌ¿Í °°Àº º¯Çü·ü ¹üÀ§¿¡¼­ÀÇ º¯Çü°è¼ö¸¦ Æò°¡ÇÏ´Â °ÍÀÌ Áß¿äÇÏ´Ù. º» ³í¹®¿¡¼­´Â ³ë»ó ÇöÀå¿¡¼­ ¹Ýº¹ÆòÆÇÀçÇϽÃÇèÀ» ÀÌ¿ëÇÏ¿© Áß°£º¯Çü·ü ¿µ¿ª¿¡¼­ÀÇ º¯Çü°è¼ö¸¦ »êÁ¤ÇÏ´Â ¹æ¹ýÀ» Á¦¾ÈÇÏ¿´´Ù. ÀÌÀÇ ½Å·Ú¼ºÀ» °ËÅäÇϱâ À§ÇÏ¿© ÇöÀå¿¡¼­ Å©·Î½ºÈ¦ ½ÃÇè°ú ½Ç³»¿¡¼­ °øÁøÁÖ½ÃÇèÀ» ¼öÇàÇÏ¿© Àüüº¯Çü·ü ¿µ¿ª¿¡¼­ÀÇ ÇöÀåÀÇ º¯ÇüƯ¼ºÀ» Æò°¡ÇÏ¿© ÆòÆÇÀçÇϽÃÇè °á°ú¿Í ºñ±³ÇÏ¿´´Ù. µÎ ½ÃÇè°á°ú »çÀÌÀÇ ÀÀ·Â»óŸ¦ °í·ÁÇÏ¸é º¯Çü·ü¿¡ µû¸¥ º¯Çü°è¼öÀÇ °ª°ú °æÇâÀÌ ºñ±³Àû ÀÏÄ¡ÇÏ¿´°í, Á¦¾ÈµÈ ¹Ýº¹½Ä ÆòÆÇÀçÇϽÃÇèÀ»ÅëÇØ ÇöÀ庯Çü°è¼öÀÇ Æò°¡°¡ °¡´ÉÇÔÀ» ¾Ë ¼ö ÀÖ¾ú´Ù.
The field plate load test has a good potential for determining modulus since it measures both plate pressure and settlement. Conventionally the modulus has been assumed to be a constant secant value defined from the settlement of the plate at a given load intensity. A constant modulus (modulus of subgrade reaction, k), however, may not be a representative value of subgrade soil under working load. Field strain(o. stress)-dependent modulus characteristics of subgrade soils, at relatively low to intermediate strains, are important in the pavement design. In this study, the field strain dependent moduli of subgrade soils were obtained using cyclic plate load test. Testing procedure and data reduction method are proposed. The field crosshole and laboratory resonant column tests were also performed to determine field nonlinear modulus at $0.001%;to;0.1%$ strains, and the modulus values and nonlinear trends are compared to those obtained by cyclic plate load tests. Both modulus values match relatively well when the different state of stress between two tests was considered, and the applicability of field cyclic plate load test for determining nonlinear modulus values of subgrade soils is verified.
 
Ű¿öµå
plate load test;field nonlinear modulus;subgrade soil;strain;state of stress;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.21, no.6, 2005³â, pp.67-79
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200504840676250)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿