|
|
|
Çѱ¹Áö¹Ý°øÇÐȸ / v.22, no.11, 2006³â, pp.89-99
|
¸¶ÀÌÅ©·ÎÆÄÀÏ·Î º¸°µÈ ÇÁ¸®Ä³½ºÆ® ÄÜÅ©¸®Æ® ¿Ëº®ÀÇ ÃÖÀûº¸°ÇüÅ¿¡ °üÇÑ ¿¬±¸
( A Study on Optimal Reinforcing Type of Precast Retaining Wall Reinforced by Micropiles ) |
| ±èÈ«ÅÃ;¹ÚÁØ¿ë;À¯ÂùÈ£; È«ÀÍ´ëÇб³ Åä¸ñ°øÇаú;GS°Ç¼³¢ß Åä¸ñ»ç¾÷ºÎ T/K¼³°èÆÀ;Çѱ¹³óÃ̰ø»ç ³ó¾îÃÌ¿¬±¸¿ø;
|
|
|
 |
|
| |
| ÃÊ ·Ï |
| ÇÁ¸®Ä³½ºÆ® ÄÜÅ©¸®Æ® ¿Ëº®Àº ÇöÀ埼³ ÄÜÅ©¸®Æ® ¿Ëº®¿¡ ºñÇØ °ø±â ´ÜÃàÈ¿°ú, ǰÁúÀÇ ¿ì¼ö¼º, ±³Åë ¹× ÀÎÁ¢±¸Á¶¹°°úÀÇ °£¼· ÃÖ¼ÒÈ µî ¸¹Àº ÀåÁ¡À» °¡Áö°í ÀÖ´Ù. ÇÏÁö¸¸ Áö¹ÝÁ¶°ÇÀÌ ºñ±³Àû ¾çÈ£ÇÑ Á÷Á¢±âÃÊÇüÅÂÀÇ °æ¿ì¿¡´Â º°µµÀÇ º¸°Á¶Ä¡¸¦ °í·ÁÇÏÁö ¾ÊÀ¸¸é ÀÚÁ߸¸À¸·Î ÀúÇ×ÇÏ°Ô µÊ¿¡ µû¶ó ¿Ëº®ÀÇ ´Ü¸éÀÌ Áõ°¡ÇÏ°Ô µÇ°í ±×¿¡ µû¸¥ ¿î¹Ý»óÀÇ ¾î·Á¿ò ¹× °ø»çºñ Áõ°¡ µîÀÇ ´ÜÁ¡ÀÌ ÀÖ´Ù. º» ¿¬±¸¿¡¼´Â ÀÌ·¯ÇÑ ¹®Á¦Á¡À» º¸¿ÏÇϱâ À§ÇÑ ¹æ¹ýÀ¸·Î ¸¶ÀÌÅ©·ÎÆÄÀϰø¹ýÀÇ Àû¿ë¼ºÀ» Æò°¡ÇØ º¸¾Ò´Ù. ¸¶ÀÌÅ©·ÎÆÄÀϰø¹ýÀº ¼ÒÇüÀåºñ·Î ½Ã°øÀÌ °¡´ÉÇϹǷΠÀÛ¾÷°ø°£ÀÇ Á¦¾àÀÌ ¾ø°í, Àúºñ¿ë ¹× °íÈ¿À²ÀÇ ÀåÁ¡À» °¡Áö°í ÀÖÀ¸³ª º¸°È¿°ú¸¦ ³ôÀ̱â À§ÇØ ¼³Ä¡ÇÑ ¸¶ÀÌÅ©·ÎÆÄÀÏÀÇ ¿ªÇÐÀû °Åµ¿Æ¯¼ºÀÌ ¸íÈ®È÷ ±Ô¸íµÇÁö ¾ÊÀº »óÅÂÀ̸ç, ¸¶ÀÌÅ©·ÎÆÄÀÏÀÇ ±æÀÌ, Á÷°æ, ¼³Ä¡°¢µµ ¹× ¼³Ä¡À§Ä¡ µî¿¡ ´ëÇÑ ¼³Ä¡±âÁØÀÌ ¾ø°í °æÇè¿¡ ÀÇÁ¸Çϰí ÀÖ´Â ½ÇÁ¤ÀÌ´Ù. µû¶ó¼ º» ¿¬±¸¿¡¼´Â ÇÁ¸®Ä³½ºÆ® ÄÜÅ©¸®Æ® ¿Ëº®¿¡ º¸°µÈ ¸¶ÀÌÅ©·ÎÆÄÀÏÀÇ ÃÖÀûº¸°ÇüÅ ¹× º¸°È¿°ú¸¦ ±Ô¸í Á¦½ÃÇϱâ À§ÇÏ¿© Ȱµ¿ ¹× Àüµµ°Åµ¿¿¡ ´ëÇÑ ½Ç³»¸ðÇü½ÇÇèÀ» °¢°¢ ½ÃÇàÇÏ¿´´Ù. ¶ÇÇÑ ½Ç³»¸ðÇü½ÇÇè °á°ú¸¦ Åä´ë·Î Á¦½ÃµÈ ¸¶ÀÌÅ©·ÎÆÄÀÏÀÇ ÃÖÀûº¸°ÇüŸ¦ °ËÁõÇϱâ À§ÇÑ ¸ñÀûÀ¸·Î À¯ÇÑ¿ä¼ÒÇØ¼® ¹× ÇѰèÆòÇüÇØ¼® µîÀÇ ¼öÄ¡ÇØ¼®À» ¼öÇàÇÏ¿© ¸¶ÀÌÅ©·ÎÆÄÀÏÀÇ ÃÖÀû º¸°ÇüŸ¦ Á¦½ÃÇÏ¿´´Ù. ½Ç³»¸ðÇü½ÇÇè°ú ¼öÄ¡ÇØ¼®À¸·Î ÇÁ¸®Ä³½ºÆ® ÄÜÅ©¸®Æ® ¿Ëº®¿¡ º¸°µÇ´Â ¸¶ÀÌÅ©·ÎÆÄÀÏÀÇ ÃÖÀûº¸°ÇüŸ¦ Æò°¡ÇÑ °á°ú, ¸¶ÀÌÅ©·ÎÆÄÀÏÀº ¿Ëº®³ôÀÌÀÇ 0.4¹è ÀúÆÇ±æÀÌÀÇ 0.04¹è ÀÏ ¶§°¡, ÃÖÀûÀÇ º¸°È¿À²À» º¸ÀÌ´Â °ÍÀ¸·Î Æò°¡µÇ¾ú´Ù. |
|
| The PCRW (Precast Concrete Retaining Wall) has many advantages compared with cast in place concrete retaining wall : shorter construction period, excellency of quality and minimum interference with the adjacent structure and traffics. However, shallow foundation type of PCRW, which has comparatively better ground condition, has some disadvantages such as difficulty in transportation and higher cost due to the size of PCRW being expanded by resisting only with self-weight if there is no other supplementary reinforcement. The presented study, in order to complement such disadvantages of PCRW, have applied the micropile method. The micropile method has advantages like low-cost and high-efficiency and does not require huge space, because it can be executed with small size equipment. However, the mechanical behavior characteristics of the PCRW reinforced by micropile, which is installed to improve the reinforcement effect, is not yet clearly identified and there is no suggested standard as to the length, diameter, install angle and install position of micropiles. Hence, this method is yet being designed depend on engineer's experience. In this study, various laboratory model tests as to sliding and overturning were performed in order to identify and present the optimum type of reinforcement and reinforcement effect of the PCRW reinforced by micropiles. In addition, it also executed numerical analysis for the purpose of verifying the optimum type of reinforcement for micropiles based on the results of laboratory model tests. The optimum reinforcement type of micropiles was estimated by model test and numerical analysis. The length of micropiles is 0.4 times wall height and the diameter is 0.04 times wall length. |
| |
| Ű¿öµå |
| Laboratory nodel test;Micropiles;Precast concrete retaining wall; |
| |
|
|
 |
|
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.22, no.11, 2006³â, pp.89-99
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200604623520161)
¾ð¾î : Çѱ¹¾î |
|
| ³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø |
|
|
|
|
|
|