¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹Áö¹Ý°øÇÐȸ / v.15, no.6, 1999³â, pp.251-262
½¯µåÅͳΠ¶óÀÌ´× »ç´Ù¸®²Ã ¼¼±×¸ÕÆ®ÀÇ ¿¬°á¹æ¹ý °³¼±¿¡ °üÇÑ ¿¬±¸
( A Study on the Improvement of Connection for Shield Tunnel Lining Using Trapezoidal Segments )
Á¤Çü½Ä;±èµµ¿­;±èÁ¤¼ö; ÇѾç´ëÇб³ °ø°ú´ëÇÐ Åä¸ñ°øÇаú;°æº¹´ëÇÐ Åä¸ñ¼³°è°ú;´ëÇÑÁÖÅðø»ç ½ÃÇè½Ç;
 
ÃÊ ·Ï
½¯µåÅͳο¡¼­ »ç¿ëÀÌ Áõ°¡µÇ°í ÀÖ´Â »ç´Ù¸®²Ã ¼¼±×¸ÕÆ®´Â ¿¬°áºÀ°ú ¿¬°á½û±â¸¦ »ç¿ëÇÏ¿© ¼¼±×¸ÕÆ®¸¦ Á¶¸³ÇÔÀ¸·Î¼­ ÅͳζóÀÌ´×À» Çü¼ºÇÏ°Ô µÈ´Ù. ÀÌ °æ¿ì »ç´Ù¸®²Ã ¼¼±×¸ÕÆ®ÀÇ Å×ÀÌÆÛ °¢µµ¸¦ Å©°Ô ÇÒ¼ö·Ï Á¶¸³½Ã°øÀÌ ¿ëÀÌÇϰí, ¶ÇÇÑ Áö¼öÀçÀÇ ¹Ð¸²Çö»óÀ» ÁÙÀÏ ¼ö ÀÖÁö¸¸ ¹Ý¸é ¿¬°áºÎÀÇ ±¸Á¶Àû ¾ÈÁ¤¼ºÀº °¨¼ÒÇÏ°Ô µÈ´Ù. º» ³í¹®¿¡¼­´Â ´Ü¸éÇü»óÀÌ ºÒ±ÔÄ¢ÇÑ ¼¼±×¸ÕÆ®¿Í ¿©·¯°¡Áö ºÎ¼ÓÀç°¡ 3Â÷¿øÀûÀ¸·Î ¿¬°áµÇ´Â ½¯µåÅͳο¡ ´ëÇØ ÇöÀåÀÇ ½Ã°ø°úÁ¤À» ¸ð»çÇÏ¿© 3Â÷¿ø ÇØ¼®À» ¼öÇàÇÏ¿´À¸¸ç, »ç´Ù¸®²Ã ¼¼±×¸ÕÆ®ÀÇ Å×ÀÌÆÛ °¢µµº¯È­$(0^{citc$mid$,; 10${circ},; 20^{circ})$¿¡ µû¸¥ ¿¬°áºÎÀÇ ÀÛ¿ë·ÂÀ» ±¸ÇÏ¿© ¿¬°áºÎ¿¡ ´ëÇÑ ¸¶ÂûÀúÇ×·Â ½ÃÇè°á°ú¿Í ºñ±³, ºÐ¼®ÇÔÀ¸·Î¼­ ¿¬°áºÎ¿¡ ´ëÇÑ °³¼±¹æ¾ÈÀ» ¸ð»öÇÏ¿´´Ù.
The assemblage of the trapezoidal segments, which is being used increasingly to shield tunnelling, with Guide rod and Dowel forms tunnel lining. In this case the larger the taper angle of trapezoidal segment is, the easier the assembly work becomes. The large angle can reduce the water proof material's phenomenon of being pushed back, but decreases the structural safety in connecting section of tunnel lining. In this paper a 3-dimensional numerical analysis was performed to estimate the exact behavior of a model shield tunnel made by connecting 3-dimensionally various accessories with irregular sectioned segments. We obtained the operating force of connecting section according to the change of taper angle of trapezoidal segment and sought for improved scheme for connecting section by comparing and analyzing the test results on the friction resistance force of connecting parts.
 
Ű¿öµå
Shield tunnelling;Trapezoidal segments;3-dimensional analysis;Guide rod;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.15, no.6, 1999³â, pp.251-262
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO199911921749906)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿