¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹°ÇÃà½Ã°øÇÐȸ / v.9, no.6, 2009³â, pp.91-98
ÁöÇÏÃþ µµ¸·¹æ¼ö°ø»çÀÇ ÁßÁ¡°ü¸®¿äÀÎ
( Critical Management Factors of Fluid-Applied Membrane Waterproofing Work for building basements )
±ÇÇØ¸²;À¯Á¤È£; ±¤¿î´ëÇб³ °ÇÃà°øÇаú ´ëÇпø;±¤¿î´ëÇб³ °ÇÃà°øÇаú;
 
ÃÊ ·Ï
°ÇÃà°ø»ç Áß Àΰ£¿¡°Ô ¸¹Àº ¿µÇâÀ» ¹ÌÄ¡´Â ½À±â¿Í ¹°¿¡ ´ëÇÑ ÇÇÇØ·ÎºÎÅÍ ÁÖ°Å »ýȰÀ» º¸È£ÇÏ´Â ¼º´ÉÀ» °¡Áø °ÍÀÌ ¹æ¼ö°ø»çÀÌ´Ù. °ÇÃà ¹æ¼ö°ø»çÀÇ ÇÏÀÚ·Î ÀÎÇÑ º¸¼öºñ´Â ¹æ¼öÃþ ÀÚüÀÇ º¸¼öºñ¿ë»Ó¸¸ ¾Æ´Ï¶ó ¿¬°è°øÁ¾ÀÇ ÇÇÇØ·Î ÀÎÇÑ ¿¬°è°øÁ¾ÀÇ º¸¼öºñ¿ë ¶ÇÇÑ Ãß°¡µÇ¾î, ¹æ¼ö°ø»çÀÇ ÀüüÀûÀÎ º¸¼öºñ¿ëÀº ´õ¿í ³ô¾ÆÁø´Ù. ÇÏÁö¸¸, ¹æ¼ö°ø»çÀÇ ÇÏÀÚ¸¦ ¹Ì¿¬¿¡ ¹æÁöÇÒ ¼ö ÀÖ´Â Á¤·®ÀûÀ̰í È¿À²ÀûÀÎ °ü¸®¹æ¾ÈÀÌ ºÎÁ·ÇÑ ½ÇÁ¤ÀÌ´Ù. ±âÁ¸ ¹®Çå °íÂû°ú »ç·Ê ºÐ¼® °á°ú, ÁöÇÏÃþ ¹æ¼ö°ø»ç ÇÏÀÚ°¡ ºó¹øÇÏ°Ô ³ªÅ¸³µÀ¸¸ç, ¿©·¯ °ø¹ý Áß µµ¸·¹æ¼ö°¡ °¡Àå ¸¹ÀÌ »ç¿ëµÇ°í ÀÖ¾ú´Ù. ÀÌ¿¡ º» ¿¬±¸¿¡¼­´Â ÁöÇÏÃþ µµ¸·¹æ¼ö°ø»ç¿¡ ´ëÇÑ ÇÏÀÚ »ç·ÊºÐ¼®À» ÇÏ¿´À¸¸ç, À̸¦ ¹Ì¿¬¿¡ ¹æÁöÇϱâ À§ÇÑ ¹æ¾ÈÀ¸·Î FMEA(Failure Mode and Effect Analysis) ±â¹ýÀ» º¯ÇüÇÑ R-FMEA ¹æ¹ýÀ» °í¾ÈÇÏ¿´´Ù. R-FMEA ½¬Æ®¿¡ ´ëÇÑ Àü¹®°¡ ¼³¹®À» ÅëÇÏ¿© ÁöÇÏÃþ µµ¸·¹æ¼ö°ø»ç ÇÏÀÚ À¯Çü Áß °¡Àå À§Ç輺ÀÌ Å« ¹æ¼ö°ø»ç ÇÏÀÚ À¯ÇüÀ» µµÃâÇÏ¿©, Áß¿äÇÏ°Ô °ü¸®µÇ¾î¾ß ÇÏ´Â ¿äÀεéÀ» µµÃâÇÏ¿´´Ù.
One role of waterproofing work is to block external moisture and water. Defects in waterproofing work in building construction brings on huge repair costs for related construction work as well as for the waterproofing layer itself. However, we don't have a quantitative probabilistic management method for waterproofing work to successfully anticipate and prevent defects. From an analysis of the literature and prior research, defects in the waterproofing work in the underground parts of buildings occur frequently. We selected Fluid-Applied Membrane waterproofing work as representing waterproofing work in the underground parts of a building, and researched the general types and causes of defects. In this study, we developed the Relative-FMEA (Failure Mode and Effect Analysis) approach that merges the Matrix method and FMEA. From a survey of experts, we deduced the most important management factors for Fluid-Applied Membrane waterproofing work for the underground parts of buildings.
 
Ű¿öµå
¹æ¼ö°ø»ç;µµ¸·¹æ¼ö;¹æ¼ö°ø»ç ÇÏÀÚ;Waterproofing Work;Fluid-Applied Membrane Waterproofing work;Defect;R-FMEA;
 
Çѱ¹°ÇÃà½Ã°øÇÐȸÁö / v.9, no.6, 2009³â, pp.91-98
Çѱ¹°ÇÃà½Ã°øÇÐȸ
ISSN : 1598-2033
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200919038644020)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿