À¯µ¿Æ¯¼ºÀ» ÀÌ¿ëÇÑ ÆóÁÖ¹°»ç È¥ÇÕ¹°ÀÇ ¿Ëº®µÞä¿òÀç ¿¬±¸
( A Study on the Flowable Backfill with Waste Foundry Sand for Retaining Wall )
Á¶ÀçÀ±;À̰üÈ£;ÀÌÀθð; Á¤È¸¿ø, µ¿Àǰø¾÷´ëÇÐ Åä¸ñ°ú;Á¤È¸¿ø, °æ¼º´ëÇб³ °ø°ú´ëÇÐ °Ç¼³¡¤È¯°æ°øÇкÎ;Á¤È¸¿ø, °í·Á´ëÇб³ °ø°ú´ëÇÐ Åä¸ñȯ°æ°øÇаú;
 
ÃÊ ·Ï
º» ¿¬±¸ÀÇ ¸ñÀûÀº ÆóÁÖ¹°»ç-ÇöóÀֽ̾¬ È¥ÇÕÀç·áÀÇ ¿Ëº® µÞä¿òÀç ÀÌ¿ë½Ã ¿Ëº®¿¡ ÀÛ¿ëÇÏ´Â Åä¾Ð°ú ¾ÈÁ¤¼º¿¡ ´ëÇÑ Æ¯¼ºÀ» Æò°¡ÇÏ´Â °ÍÀÌ´Ù. ¼¼Á¾·ùÀÇ ÆóÁÖ¹°»ç(»ýÇü»ç, ÈĶõ»ç, ÄÚÆ¼µå»ç)¿Í ASTM ºÐ·ù ±âÁØ F µî±ÞÀÇ ÇöóÀֽ̾¬¸¦ ÀÌ¿ëÇÑ À¯µ¿¼º µÞä¿òÀçÀÇ ¿Ëº® Àû¿ë¼ºÆò°¡¸¦ À§ÇØ ÀÎÀ§Àû º¯À§Á¦¾î ½ÇÇè ¹× ÀÚÀ¯º¯À§Á¦¾î½ÇÇèÀ» ÀÌ¿ëÇÏ¿© ¸ðÇü¿Ëº®½ÇÇèÀ» ¼öÇàÇÏ¿´´Ù. ÀÎÀ§Àû º¯À§Á¦¾î½ÇÇèÀÇ °æ¿ì À¯µ¿¼º µÚä¿òÀÇ Å¸¼³ Á÷ÈÄ Åä¾Ð°è¼öÀÇ Å©±â´Â 0.8~1 »çÀÌÀÇ °ªÀ¸·Î ³ªÅ¸³µ°í, ¾à 12½Ã°£ÀÌ °æ°úÇÏ¸é ¿Ëº®¿¡ ÀÛ¿ëÇÏ´Â Åä¾ÐÀÌ »ó´çºÎºÐ Àú°¨µÇ¾ú´Ù. 2´Ü°è Ÿ¼³ ¹æ¹ýÀ» Àû¿ëÇÑ ÀÚÀ¯º¯À§½ÇÇèÀÇ °æ¿ì, ½½·¯¸® ÇüÅÂÀÇ À¯µ¿¼º µÚä¿òÀçÀÇ Å¸¼³Ãʱ⿡ ÈĶõ»ç¿Í ÄÚÆ¼µå»ç È¥ÇÕÀç´Â ºü¸¥ ¹è¼öÈ¿°ú¿¡ ÀÇÇØ Åä¾Ð °æ°¨ È¿°ú°¡ »¡¸® ³ªÅ¸³µÁö¸¸, 1ÀÏ ÈÄÀÇ Åä¾ÐÀº °°Àº ¾ç»ý½Ã°£ÀÇ »ýÇü»ç¿¡ ºñÇØ Å©°Ô À¯ÁöµÇ¾ú´Ù. ¸ðÇü½ÇÇèÀÇ ÀÚÀ¯º¯À§Á¦¾î ½ÇÇè°á°ú¸¦ ÀÌ¿ëÇÑ ¾ÈÁ¤¼º ÇØ¼®À¸·ÎºÎÅÍ 6m ¿Ëº®¿¡ Ÿ¼³ÇÒ ¼ö ÀÖ´Â µÚä¿òÀçÀÇ ½Ã°ø´Ü°èº° 1Â÷Ÿ¼³ ³ôÀÌ ¹× 2Â÷Ÿ¼³ ³ôÀÌ´Â »ýÇü»çÀÇ °æ¿ì 3.9m ¹× 3.57m, ÈĶõ»çÀÇ °æ¿ì 4.07m ¹× 3.64m, ÄÚÆ¼µå»çÀÇ °æ¿ì 3.86m ¹× 3.54m, È¥ÇÕ»çÀÇ °æ¿ì 3.9m ¹× 3.44m·Î °áÁ¤µÇ¾ú°í, ½ÇÁ¦ ¿Ëº®ÀÇ µÚä¿ò ³ôÀÌ 5.4mº¸´Ù Å©¹Ç·Î 2´Ü°è ½Ã°øÀ¸·Î ¿Ëº®ÀÇ µÚä¿òÀ» ¿Ï°øÇÒ ¼ö ÀÖ´Â °ÍÀ¸·Î ÆÇÁ¤µÇ¾ú´Ù. ¶ÇÇÑ Àç·áÀÇ ¾ç»ýƯ¼º¿¡ µû¸¥ ¿Ëº®ÀÇ ¾ÈÁ¤¼ºÀº ¾ç»ý±â°£ÀÌ °æ°úÇÔ¿¡ µû¶ó ´õ¿í Áõ°¡µÇ´Â °á°ú¸¦ ³ªÅ¸³»¾ú´Ù.
The objective of this study is to evaluate the lateral earth pressure and the stability of small scale retaining wall with waste foundry sand(WFS) mixtures as a controlled low strength materials (CLSM). Three different types of WFS, like Green WFS, Hurane WFS and Coated WFS, were used in this study, and fly ash of Class F type was adopted. To evaluate the lateral earth pressure and the stability of retaining wall, two different samll scale retaining wall tests, which are called an artificially controlled strain method and a natural strain method, were carried out. In case of an artificially controlled strain method, the coefficient of lateral earth pressure, just after backfilling of WF mixtures, was around 0.8 to 1.0, and most of earth pressure was dissipated within 12 hours. In case of a natural strain method, two steps of stage constructions were employed. The mixtures of Hurane WFS and Coated WFS showed fast decrease of earth pressure due to a relatively good drainage. Judging from the sta bility of retaining wall for overturning and sliding, two steps of stage construction for 2 days were enough to finish the backfill of 6-m height of retaining wall. Also, considering the curling effect of WFS mixtures, the stability of retaining wall increased as curling time increased.
 
Ű¿öµå
Controlled low-strength material(CLSM);Flowable backfill Fly-ash;Lateral earth pressure;Retaining wall;Waste foundry sand(WFS);
 