Çѱ¹°ÇÃà½Ã°øÇÐȸ / v.9, no.5, 2009³â, pp.155-161
°æ»çÀÎÀåÇü ¹Ì²ô·³½ÃÇè±â(O-Y·PSM)¿ÍÀÇ ºñ±³½ÇÇèÀ» ÅëÇÑ ÈÞ´ëÇü ¹Ì²ô·³½ÃÇè±â(ONO·PPSM)ÀÇ ±³Á¤½Ä ÀÛ¼º
( Development of Calibration Equation of Portable Slip Meter(ONO·PPSM) through Comparative test of O-Y·PSM and ONO·PPSM )
½ÅÀ±È£;ÃÖ¼ö°æ; ÇѼ­´ëÇб³ °ÇÃà°øÇаú;ÇѼ­´ëÇб³ °ÇÃà°øÇаú;
 
ÃÊ ·Ï
º» ¿¬±¸¿¡¼­´Â ½ÃÇè¹æ¹ýÀÇ °úÇÐÀû ¿ì¼ö¼º¿¡µµ ºÒ±¸Çϰí Áß·®À¸·Î ÀÎÇØ ÇöÀå¿¡¼­ÀÇ ¿î¿ëÀÌ °ï¶õÇÑ °æ»çÀÎÀåÇü ¹Ì²ô·³½ÃÇè±â(O-Y PSM)¿¡ ´ëÀÀÇÏ¿© °³¹ßµÈ ÈÞ´ëÇü ¹Ì²ô·³½ÃÇè±â(ONO PPSM)¸¦ ´ë»óÀ¸·Î, ¹Ì²ô·³ÀúÇ× ÃøÁ¤°ªÀÇ ¾ÈÁ¤¼ºÀ» ½ÇÇèÀ» ÅëÇØ È®ÀÎÇϰí PVC°è ¹Ù´ÚÀç ¹× ¹«±âÁú°è ¹Ù´ÚÀç¿¡ ´ëÇÑ ¹Ì²ô·³½ÃÇèÀ» ´Ù°¢µµ·Î ½Ç½ÃÇÏ¿© ±× Ÿ´ç¼ºÀ» º¸´Ù ½Éµµ ±í°Ô °ËÁõÇÏ¿´´Ù. ¶ÇÇÑ ´Ù¾çÇÑ ÀçÁú, Ç¥¸é»óÅÂÀÇ ¹Ù´ÚÀç¿¡ ´ëÇÑ O-Y PSM°ú ONO PPSMÀÇ ¹Ì²ô·³ÀúÇ× ºñ±³½ÇÇèÀ» ÅëÇÏ¿© C.S.R°ú C.S.R'ÀÇ ¹Ì²ô·³ Æò°¡ÁöÇ¥¸¦ °øÀ¯Çϱâ À§ÇÑ ±³Á¤½ÄÀ» »õ·Ó°Ô Á¦¾ÈÇÔÀ¸·Î½á ONO PPSMÀÇ ¹Ì²ô·³½ÃÇè±â·Î¼­ ¹ü¿ë¼ºÀ» ´õ ÇÑÃþ Á¦°íÇÏ¿´´Ù.
This paper is the result of an investigation of a PORTABLE SLIP METER(ONO PPSM) by means of an experiment to determine its validity as a slip meter. ONO PPSM is a portable slip meter that was designed to address the weak points of PULL SLIP METER(O-Y PSM), which can be used to obtain an accurate measurement of slip resistance, but is very heavy and difficult to operate. To determine the stability of the measurement result of ONO PPSM, we measured the slip resistance against 4 different kind of floor materials. Our findings showed that the coefficient of variability of CSR' is less than 0.05. Furthermore, we verified the relationship between CSR' and CSR. More specifically, by performing the slip test against 7 different kinds of inorganic matter floor materials, we increased the usability of ONO PPSM as a slip meter by suggesting a method of sharing the evaluation index of slip of CSR' and C.S.R.
 
Ű¿öµå
¹Ì²ô·³;°æ»çÀÎÀåÇü ¹Ì²ô·³½ÃÇè±â;ÈÞ´ëÇü ¹Ì²ô·³½ÃÇè±â;±³Á¤½Ä;slipperiness;O-Y.PSM;Portable Slip Meter(ONO.PPSM);calibration equation;
 