¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹Áö¹Ý°øÇÐȸ / v.22, no.7, 2006³â, pp.45-54
Áö¹Ý ¿À¿°µµ Á¶»ç¸¦ À§ÇÑ Àü±âºñÀúÇ×/Á¤Àü¿ë·® ÃøÁ¤ÄÜÀÇ Àû¿ë¼º Æò°¡
( Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination )
¿À¸íÇÐ;±è¿ë¼º;¹ÚÁعü; Çѱ¹Çؾ翬±¸¿ø ¿¬¾È°³¹ß¿¬±¸º»ºÎ;¼­¿ï´ëÇб³ Áö±¸È¯°æ½Ã½ºÅÛ°øÇкÎ;¼­¿ï´ëÇб³ Áö±¸È¯°æ½Ã½ºÅÛ°øÇкÎ;
 
ÃÊ ·Ï
Àü±âºñÀúÇ×ÄÜÀº ÇöÀå¿¡¼­ Áö¹ÝÀÇ ¿À¿°´ë¸¦ Á¶»çÇϴµ¥ »ó´ëÀûÀ¸·Î °æÁ¦ÀûÀÎ ºñ¿ëÀ¸·Î Àû¿ëµÉ ¼ö ÀÖ´Ù. ±×·¯³ª, Àü±âºñÀúÇ× °á°ú¸¸¿¡ ÀÇÇÑ ÇØ¼®Àº Á¤·®Àû µ¥ÀÌÅͺ£À̽ºÀÇ ºÎÁ·°ú ÇÔ¼öºñ µîÀÇ ´Ù¸¥ Áö¹Ý°øÇÐÀû ¿µÇâÀÎÀڵ鿡 ÀÇÇØ ¸ðÈ£ÇÑ °á°ú¸¦ ³ªÅ¸³¾ ¼ö ÀÖ´Ù. º» ¿¬±¸¿¡¼­´Â Áö¹Ý¿À¿°Á¶»ç¿¡¼­ÀÇ Àü±âºñÀúÇ× ÃøÁ¤±â¹ýÀ» º¸¿ÏÇϱâ À§ÇÏ¿© Á¤Àü¿ë·® ÃøÁ¤±â¹ýÀ» µµÀÔÇÏ¿© Á߱ݼӰú À¯·ù·Î ¿À¿°µÈ Áö¹Ý¿¡¼­ÀÇ Àû¿ë¼ºÀ» Æò°¡ÇϰíÀÚ ÇÏ¿´´Ù. ÇÔ¼öºñ¿Í ¿À¿°¹°ÁúÀÇ Á¾·ù¿¡ µû¸¥ Àü±âºñÀúÇ×°ú Á¤Àü¿ë·®ÀÇ º¯È­¸¦ Æò°¡Çϱâ À§ÇÏ¿© ½Ç³»¸ðÇü½ÃÇèÀ» ¼öÇàÇÏ¿´À¸¸ç, ±× °á°ú Àü±âºñÀúÇ×°ú À¯Àü»ó¼ö¸¦ Åë½Ã¿¡ ÃøÁ¤ÇÏ¿© ºÐ¼®ÇÔÀ¸·Î½á ¿À¿°´ëÀÇ °¨Áö¿¡ ½Å·Úµµ¸¦ ³ôÀÏ ¼ö ÀÖ´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù. Àü±âºñÀúÇ×°ú Á¤Àü¿ë·® ÃøÁ¤±â¹ýÀº Á߱ݼÓÀ¸·Î ¿À¿°µÈ Æ÷È­Áö¹Ý°ú ÁöÇϼö´ë »óºÎ¿¡ Á¸ÀçÇÏ´Â µðÁ©À¯ ¿À¿°ÃþÀ» °¨ÁöÇÏ´Â µ¥ Àû¿ë¼ºÀÌ ³ôÀº °ÍÀ¸·Î ³ªÅ¸³µ´Ù.
Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for in-situ delineation of subsurface contamination. While the resistivity measurement has a potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements. This study is focused on verifying the applicability of resistivity and capacitance measurements of CPT module to provide information on subsurface contaminated by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination. Electrical measurements of the CPT module showed high applicability to be used in detecting saturated soils contaminated by heavy metal and diesel plume floating above the groundwater table.
 
Ű¿öµå
Capacitance;Cone penetrometer test;Diesel fuel contamination;Electrical resistivity;Heavy metal contamination;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.22, no.7, 2006³â, pp.45-54
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200634515068119)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿