¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹Áö¹Ý°øÇÐȸ / v.22, no.9, 2006³â, pp.23-36
±Ù»çÀûÀÎ ÇØ¼®¹ý¿¡ ÀÇÇÑ ±ÙÀÔµÈ º®Ã¼ÀÇ ±ØÇÑÁöÁö·Â Æò°¡
( Assessment of Ultimate Bearing Capacity for an Embedded Wall by Closed-Form Analytical Solution )
ÀÌ¿ëÁÖ; ;
 
ÃÊ ·Ï
º» ¿¬±¸´Â »çÁúÅä Áö¹Ý¿¡ ±ÙÀԵǾî ÀÖ´Â º®Ã¼ÀÇ ±ØÇÑÁöÁö·ÂÀ» ±¸Çϱâ À§ÇØ »õ·Î¿î ±Ù»çÀûÀÎ ÇØ¼®¹ýÀÇ Àü°³°úÁ¤¿¡ ´ëÇØ ¼³¸íÇÑ´Ù. ÀÌ·¯ÇÑ ±Ù»çÀûÀÎ ÇüÅÂÀÇ ÇØ¼®±â¹ýÀº »ó°è ¹× Çϰè¹ýÀ¸·Î ±¸¼ºµÇ¾î ÀÖ´Ù. »ó Çϰè¹ýÀ¸·Î °è»êµÈ °ªÀº ¼Ò¼º¿µ¿ª¿¡¼­ ±¸ÇØÁø 2Â÷¿ø ½Ç³»º®Ã¼¸ðÇüÀÇ ÇÏÁßÀçÇϽÃÇè ¹× À¯ÇÑ¿ä¼ÒÇØ¼® °á°ú¿Í ºñ±³ÇÏ¿´´Ù. ºñ±³ °á°ú, ¸ðÇü½ÇÇè°ú À¯ÇÑ¿ä¼ÒÇØ¼®À¸·ÎºÎÅÍ ±¸ÇÑ ±ØÇÑÇÏÁß °ªÀº »ó°è¿Í ÇÏ°è »çÀÌ¿¡ ¸ðµÎ ºÐÆ÷ÇÏ´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù. ÀÌ·¯ÇÑ ºñ±³¿¡¼­ ƯÀÌ ÇÒ »çÇ×Àº Çϰè¹ýÀ¸·Î ±¸ÇÑ º®Ã¼ÀÇ ±ØÇÑÇÏÁßÀÌ ¸ðÇü½ÇÇè ¹× À¯ÇÑ¿ä¼ÒÇØ¼®¿¡¼­ ±¸ÇÑ ±ØÇÑÇÏÁß°ú Àß ÀÏÄ¡µÇ´Â °ÍÀ» º¸¿© ÁÖ¾ú´Ù. ±×·¯³ª, Æò¸éº¯Çü·ü Á¶°Ç¿¡¼­ ±âÁ¸ÀÇ °æÇèÀûÀÎ ½Ä¿¡ ÀÇÇÑ °è»ê¿¡¼­ ¾ò¾îÁø ±ØÇÑÇÏÁßÀº Çϰè¹ýÀÇ ±ØÇÑÇÏÁß¿¡ ÈξÀ ¸ø ¹ÌÄ¡´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù.
This study presents the development of a new closed-form analytical solution for the ultimate bearing capacity of an embedded wall in a granular mass. The closed-form analytical solution consists of upper and lower bound solutions (UB and LB). The calculated values from these bound solutions were compared with the author's two-dimensional laboratory wall model loading test and finite element analysis in the plastic region. The comparison showed that ultimate bearing loads from both the model test and finite element analysis are located between UB and LB. In particular, the ultimate bearing load from LB showed good agreement with the ultimate bearing load values from both the model test and finite element analysis. However, the calculated value from the conventional empirical form subjected to plane-strain conditions was shown to be much smaller than the LB.
 
Ű¿öµå
Closed-form analytical solution;Embedded wall;Finite element analysis;Model wall loading test;UB and LB;Ultimate bearing capacity;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.22, no.9, 2006³â, pp.23-36
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200634515067381)
¾ð¾î : ¿µ¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿