¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹Áö¹Ý°øÇÐȸ / v.23, no.1, 2007³â, pp.23-37
dzȭ¾Ï¿¡ ±ÙÀÔµÈ ¼±´ÜÈ®ÀåÇü PHC ¸»¶ÒÀÇ ¼±´ÜÁöÁö·Â
( End Bearing Capacity of Pile Tip-enlarged PHC Piles in Weathered Rock )
À¯Ãæ½Ä;Çã°©¼ö;¼Û±â¿ë;±è¼±ºó; ¼º±Õ°ü´ëÇб³ Åä¸ñȯ°æ°øÇаú;±Øµ¿°Ç¼³ ÁÖ½Äȸ»ç ±â¼ú¿¬±¸¼Ò;ÀÌ¿¢½ºÆ¼ À¯ÇÑȸ»ç;¼º±Õ°ü´ëÇб³ Åä¸ñȯ°æ°øÇаú;
 
ÃÊ ·Ï
¸ÅÀÔ°ø¹ýÀ¸·Î ½Ã°øµÇ´Â PHC ¸»¶ÒÀÇ ¼±´ÜÁöÁö·Â ÁõÁø ¹æ¾ÈÀ¸·Î¼­ ¼±´Ü¿¡ ¼±´ÜÈ®ÀåÆÇÀ» ¼³Ä¡ÇÏ¿© ¼±´Ü È®ÀåÀ» ÅëÇØ ¼±´ÜÁöÁö·ÂÀ» Áõ°¡½ÃŰ´Â °³³ä(Àϸí Ext-PHC ¸»¶Ò)ÀÌ °³¹ßµÇ¾î ÇöÀå¿¡ Àû¿ëµÇ°í ÀÖ´Ù. º» ¿¬±¸¿¡¼­´Â Ext-PHC ¸»¶ÒÀÇ ¼±´ÜÁöÁö·Â Áõ°¡ È¿°ú¸¦ È®ÀÎÇϰí ÇöÀå Àû¿ë¼º °ËÅäÀÇ ÀÏȯÀ¸·Î Á÷°æ 400mm ¸»¶Ò¿¡ ´ëÇÑ ÇöÀåÀçÇϽÃÇèÀ» ½Ç½ÃÇÏ¿´À¸¸ç °ËÁõµÈ À¯ÇÑ¿ä¼ÒÇØ¼® ¸ðµ¨À» ÀÌ¿ëÇÏ¿© ´Ù¾çÇÑ Á¶°Ç¿¡ ´ëÇÑ ¸Å°³º¯¼ö ¿¬±¸¸¦ ½Ç½ÃÇÏ¿´´Ù. ÇöÀåÀçÇϽÃÇè °á°ú¸¦ ºÐ¼®ÇÑ °á°ú Ext-PHC ¸»¶ÒÀÇ ¼±´ÜÁöÁö·ÂÀº PHC ¸»¶Ò ´ëºñ ¾à $40{sim}50%$ Áõ°¡µÇ´Â °ÍÀ¸·Î ³ªÅ¸³µÀ¸¸ç ´Ù¾çÇÑ º¯¼ö¿¡ ´ëÇÑ ¸Å°³º¯¼ö °á°ú¿¡¼­´Â ¼±´Ü ÁöÁöÃþÀÇ ¿ªÇÐÀû Ư¼º°ú ¸»¶Ò ±æÀÌ¿¡ µû¶ó ÀÏ¹Ý PHC ´ëºñ ¼±´ÜÁöÁö·Â Áõ°¡ºñ´Â $1.2{sim}1.4$ Á¤µµ¸¦ º¸ÀÌ´Â °ÍÀ¸·Î ºÐ¼®µÇ¾ú´Ù. ÀÌ·¯ÇÑ ¿¬±¸°á°ú¿¡ ±Ù°ÅÇÒ ¶§ º» ¿¬±¸¿¡¼­ °í·ÁÇÑ ½Ã°øÁ¶°Ç¿¡ ÀÖ¾î Ext-PHC ¸»¶ÒÀ» Àû¿ëÇÔÀ¸·Î½á ÀÏ¹Ý PHC ¸»¶ÒÀÇ ¼±´ÜÁöÁö·Â ÁõÁø È¿°ú¸¦ È®º¸ÇÒ ¼ö ÀÖ´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù.
Recently a concept of pile-tip enlarged PHC pile (Ext-PHC pile), for use in the auger-drilled construction method, has been developed and is being implemented in practice. A series of field axial load tests on both PHC and Ext-PHC piles were conducted at an experimental site. In addition, a parametric study on a number of influencing factors was made using a validated finite element model. The field axial load tests indicated an enhanced load-settlement characteristics for the Ext-PHC piles compared with the PHC piles, giving approximately 50% increase in the end bearing capacity. Also found in the results of the parametric study was that the increase in the end bearing capacity of Ext-PHC piles slightly varies with the mechanical properties of supporting ground as well as pile length, in the range of 1.25 to 1.4 time that of PHC. Overall, the results of the field tests as well as the numerical study confirmed that the end bearing capacity of PHC pile can be improved by the concept of.Ext-PHC pile.
 
Ű¿öµå
Auger-drilled pile;Axial load test;End bearing capacity;Finite element analysis;PHC pile;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.23, no.1, 2007³â, pp.23-37
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200708508460648)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿