¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹Áö¹Ý°øÇÐȸ / v.23, no.11, 2007³â, pp.87-98
õ°øÀúÇ×½ÃÇè¿¡ ÀÇÇÑ ÄÜÅ©¸®Æ® ÅͳζóÀÌ´×ÀÇ ¿ªÇÐÀû Ư¼º ÃßÁ¤
( Estimation of the Mechanical Properties of the Concrete Tunnel Lining by Drilling Resistance Test )
ÃÖ¼ø¿í;¼º¿¬Ã¢;Á¤È£¼·;Àå¼öÈ£; Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ÁöÇϱ¸Á¶¹°¿¬±¸½Ç;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ÁöÇϱ¸Á¶¹°¿¬±¸½Ç;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ÁöÇϱ¸Á¶¹°¿¬±¸½Ç;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ÁöÇϱ¸Á¶¹°¿¬±¸½Ç;
 
ÃÊ ·Ï
È­Àç ÈÄ ÅͳΠ±¸Á¶¹°ÀÇ ½Å¼ÓÇÑ º¹±¸¸¦ À§ÇÏ¿© È­Àç¼Õ»ó ±¸°£À» Á¤È®ÇÏ°í ºü¸£°Ô ÆÄ¾ÇÇÏ´Â °ÍÀÌ ¹«¾ùº¸´Ùµµ Áß¿äÇÏ´Ù°í ÇÒ ¼ö ÀÖ´Ù. º» ¿¬±¸¿¡¼­´Â È­Àç·Î ÀÎÇÑ ¶óÀÌ´× ÄÜÅ©¸®Æ®ÀÇ ¿ªÇÐÀû Ư¼º º¯°ú¸¦ ¶óÀÌ´×ÀÇ µÎ²²¹æÇâÀ¸·Î ¿¬¼ÓÀûÀ¸·Î ÃøÁ¤Çϱâ À§ÇÑ Ãµ°øÀúÇ×½ÃÇè¹ýÀ» Á¦¾ÈÇϰí, õ°ø½ÃÇèÀ¸·ÎºÎÅÍ ÃøÁ¤µÈ õ°ø º¯¼öµé·ÎºÎÅÍ ¸ð¸£Å¸¸£¿Í ÄÜÅ©¸®Æ®ÀÇ ¿ªÇÐÀû Ư¼ºÀ» ÃßÁ¤ÇϰíÀÚ ÇÏ¿´´Ù. ºñ±³Àû ±ÕÁúÇÑ ¸ð¸£Å¸¸£¿¡ ´ëÇÏ¿© ÀÏ·ÃÀÇ Ãµ°øÀúÇ×½ÃÇèÀ» ½Ç½ÃÇÑ °á°ú, ºÐ´çȸÀü¼ö°¡ 1,300rpm, °üÀÔ¼Óµµ°¡ 1.40mm/sec, ±×¸®°í ºñÆ®Á÷°æÀÌ 10mmÀÎ °æ¿ì¿¡ ÃøÁ¤µÈ õ°ø ¹Ý·Â°ªÀÇ ÆíÂ÷°¡ °¡Àå ÀÛ°Ô ³ªÅ¸³ª ÃÖÀûÀÇ ½ÃÇèÁ¶°ÇÀ¸·Î ÆÇº°ÇÒ ¼ö ÀÖ¾ú´Ù. ÃÖÀû ½ÃÇèÁ¶°Ç¿¡¼­ ¸ð¸£Å¸¸£¿¡ ´ëÇØ õ°øÀúÇ×½ÃÇèÀ» ½Ç½ÃÇÑ °á°ú, õ°ø¹Ý·Â°ú ¸ð¸£Å¸Æ®ÀÇ ¾ÐÃà°­µµ ¹× ź¼º°è¼ö »çÀÌÀÇ °áÁ¤°è¼ö°¡ °¢°¢ 0.91 ¹× 0.93À¸·Î ³ªÅ¸³ª ¾çÈ£ÇÑ »ó°ü°ü°è¸¦ µµÃâÇÒ ¼ö ÀÖ¾ú´Ù. ¶ÇÇÑ ÄÜÅ©¸®Æ®¿¡ Á¸ÀçÇÏ´Â °ñÀçÀÇ ¿µÇâÀ» °í·ÁÇϱâ À§ÇÏ¿© ¹Ý·Â ¿¡³ÊÁö °³³äÀ» Á¦½ÃÇÏ¿´°í ½ÇÁ¦ ¾ÐÃà°­µµ¿ÍÀÇ °áÁ¤°è¼ö´Â 0.94·Î¼­ ¿ª½Ã ¾çÈ£ÇÑ »ó°ü°ü°è¸¦ µµÃâÇÒ ¼ö ÀÖ¾ú´Ù. ÀÌ»ó°ú °°ÀÌ Ãµ°ø ºñÆ®ÀÇ °üÀÔ°ú µ¿½Ã¿¡ ¿¬¼ÓÀûÀ¸·Î Àç·áÀÇ ¿ªÇÐÀû Ư¼ºÀ» ÃßÁ¤ÇÒ ¼ö Àִ õ°øÀúÇ×½ÃÇèÀÇ Àû¿ë °¡´É¼ºÀ» ÆÄ¾ÇÇÒ ¼ö ÀÖ¾ú´Ù.
For the quick rehabilitation of a fire-damaged tunnel structure, it is the most important procedure to investigate the fire-induced damaged zone rapidly. This study aims to propose a new drilling resistance testing method by which mechanical properties of tunnel concrete lining altered by high temperature can be estimated easily and continuously. Especially, it alms to derive the relationships to estimate mechanical properties of mortar and concrete materials from drilling parameters. To obtain the optimum testing condition, a series of drilling resistance tests were carried out for mortar specimens. When the rotation per minute of drill bit, tile penetration rate and the bit diameter were 1,300 rpm, 1.40 mm/sec, and 10 mm respectively, the deviation of measured drilling resistance forces was minimal. Under the optimum testing condition, the relationships between drilling resistance and mechanical properties of mortar specimens were shown to be very favorable. The concept of replacing a mean value of resistance farces measured during drilling with the resistance energy was proposed to consider the effects of randomly distributed aggregates inside a concrete material on drilling resistance. When the concept was applied to concrete materials, a favorable relationship between actual compressive strength and drilling resistance energy was also successfully derived.
 
Ű¿öµå
Damage;Drilling resistance test;Fire;Mechanical property;Tunnel;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.23, no.11, 2007³â, pp.87-98
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200706414119263)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿