Çѱ¹Áö¹Ý°øÇÐȸ / v.25, no.9, 2009³â, pp.45-55
|
¾ÐÃàÆÄ ¼Óµµ¸¦ ÀÌ¿ëÇÑ Ã¶µµ Åä°ø³ë¹ÝÀÇ Ç°Áú°ü¸® ¹æ¾È : I. ¿¹ºñ¿¬±¸
( A Methodology for Quality Control of Railroad Trackbed Fills Using Compressional Wave Velocities : I. Preliminary Investigation ) |
| ¹Úö¼ö;¸ñ¿µÁø;ÃÖÂù¿ë;ÀÌÅÂÈñ; Çѱ¹Ã¶µµ±â¼ú¿¬±¸¿ø Â÷·û±Ëµµ¿¬±¸½Ç;°æÈñ´ëÇб³ Åä¸ñ°ÇÃà´ëÇÐ;Çѱ¹Ã¶µµ±â¼ú¿¬±¸¿ø öµµ±¸Á¶¿¬±¸½Ç;°æÈñ´ëÇб³ Åä¸ñ°øÇаú;
|
|
|
 |
|
| |
| ÃÊ ·Ï |
| öµµ Åä°ø³ë¹ÝÀÇ Ç°ÁúÀº ÇöÀå ¹Ðµµ³ª ÆòÆÇÀçÇϽÃÇèÀ» ÅëÇØ °ü¸®µÇ¾î ¿Ô´Ù. ÇöÀç Áö¹Ý¹Ý·Â°è¼ö($k_{30}$)ÀÇ °æ¿ì ÀϹÝöµµ¿Í °í¼ÓöµµÀÇ ¼³°è±âÁØÀ¸·Îµµ »ç¿ëµÇ±â ¶§¹®¿¡ ¼³°è¿Í ǰÁú°ü¸®¿¡¼ Àϰü¼ºÀ» °®´Â´Ù. ±×·³¿¡µµ ºÒ±¸Çϰí Áö¹Ý¹Ý·Â°è¼ö($k_{30}$), ¶Ç´Â ¹Ýº¹ÆòÆÇÀçÇϽÃÇèÀÇ °á°úÀÎ º¯Çü°è¼ö($E_{v2}$)¿Í º¯Çü°è¼öÀÇ ºñ($E_{v2}/E_{v1}$) °°Àº ¼³°èÀÎÀÚ¿¡ ´ëÇØ °£ÆíÇÑ ½Ç³»±âÁØ ¼³Á¤ ¹æ¹ýÀÌ ¾ø¾î ¼³°è°úÁ¤ÀÇ Ä¡¸íÀûÀÎ °áÇÔÀ¸·Î ³²´Â´Ù. º» ¿¹ºñ¿¬±¸¿¡¼´Â ÀÌ·¯ÇÑ ´ÜÁ¡À» ±Øº¹ÇϰíÀÚ ÃÖ±Ù °³¹ßµÈ öµµ Åä°ø³ë¹ÝÀÇ ¿ªÇÐÀû-°æÇèÀû ¼³°è ¹æ¹ý¿¡µµ ÇÕ´çÇÑ »õ·Î¿î ǰÁú°ü¸® ±âÁØÀ¸·Î ¾ÐÃàÆÄ ¼Óµµ¸¦ µµÀÔÇÏ¿´°í °èÃø ±â¹ýÀ» Á¦¾ÈÇÏ¿´´Ù. ǰÁú°ü¸® ¹æ¾ÈÀÇ ÇÙ½ÉÀº ´ÙÁü½ÃÇè°ú º´ÇàÇÏ¿© ȹµæÇÑ ÃÖÀûÇÔ¼öºñ¿¡¼ÀÇ ¾ÐÃàÆÄ ¼Óµµ¸¦ ÇöÀåÀÇ Ç°Áú°ü¸® ±âÁØÀ¸·Î ¼³Á¤Çϰí ÇöÀå¿¡¼´Â ½Ã°ø Áß¿¡ Á÷Á¢µµ´ÞÆÄ ±â¹ýÀ¸·Î ǰÁúÀ» È®ÀÎÇÏ´Â °ÍÀÌ´Ù. Á÷Á¢µµ´ÞÆÄ ±â¹ýÀº ÇöÀåÀÇ ±â¼úÀÚ°¡ ÁöÇ¥¸é ¾èÀº ±íÀÌÀÇ ±ÕÁúÇÑ Ãþ¿¡¼ °£ÆíÇÏ°Ô Àû¿ëÇÒ ¼ö ÀÖ°í Àú¸²ÇÏ¸ç °á°úÀÇ ½Å·Ú¼ºÀÌ ³ô´Ù. ½ÃÇè ºÎÁö¿¡¼ Á÷Á¢µµ´ÞÆÄ ½ÃÇèÀ¸·ÎºÎÅÍ °èÃøÇÑ ¾ÐÃàÆÄ ¼Óµµ°¡ ´ÙÁüµµ¿¡ µû¶ó ½Äº° °¡´ÉÇÑÁö È®ÀÎÇÏ¿´°í, ǰÁú°ü¸® ÁöÇ¥·Î¼ ¾ÐÃàÆÄ ¼Óµµ¸¦ È¿°úÀûÀ¸·Î Àû¿ëÇÒ ¼ö ÀÖÀ½À» ÀÔÁõÇÏ¿´´Ù. º» ³í¹®ÀÇ ÇöÀå ¹× ½Ç³» ¾ÐÃàÆÄ °èÃøÀ» ÅëÇØ µ¿¹Ý³í¹®(¹Úö¼ö µî, 2009)¿¡¼ ¼öÇàÇÒ ½ÇÇèÀû Åä´ë¸¦ ¸¶·ÃÇÏ¿´´Ù. |
|
| The quality of railroad trackbed fills has been controlled by field measurements of density and bearing resistance of plate-load tests. The control measures are compatible with the design procedures whose design parameter is $k_{30}$ for both ordinary-speed railways and high-speed railways. However, one of fatal flaws of the design procedures is that there are no simple laboratory measurement procedures for the design parameters ($k_{30}$ or, $E_{v2}$ and $E_{v2}/E_{v1}$) in design stage. To overcome the defect, the compressional wave velocity was adopted as a control measure, in parallel with the advent of the new design procedure, and its measurement technique was proposed in the preliminary investigation. The key concept of the quality control procedure is that the target value for field compaction control is the compressional wave velocity determined at optimum moisture content using modified compaction test, and direct-arrival method is used for the field measurements during construction, which is simple and reliable enough for practice engineers to access. This direct-arrival method is well-suited for such a shallow and homogeneous fill lift in terms of applicability and cost effectiveness. The sensitivity of direct-arrival test results according to the compaction quality was demonstrated at a test site, and it was concluded that compressional wave velocity can be effectively used as quality control measure. The experimental background far the companion study (Park et al., 2009) was established through field and laboratory measurements of the compressional wave velocity. |
| |
| Ű¿öµå |
| Compressional wave velocity;Direct-arrival method;Modified compaction test;Railroad trackbed fills;Quality control; |
| |
|
|
 |
|
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.25, no.9, 2009³â, pp.45-55
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200934939599699)
¾ð¾î : Çѱ¹¾î |
|
| ³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø |
|
|
|
|
|
|