Çѱ¹Áö¹Ý°øÇÐȸ / v.17, no.6, 2001³â, pp.5-14
¾ïÁö¸»¶Ò °£Æí¼³°è¹ý ¹× ÀûÀÀ¼º ºÐ¼®
( Simplified Design Method for Stabilizing Piles and its Application )
Á¤»ó¼¶;¿øÁø¿À;¹ÚÁß¹è;±è¼º¿­; ¿¬¼¼´ëÇб³ °ø°ú´ëÇÐ Åä¸ñ°øÇаú;¿¬¼¼´ëÇб³ °ø°ú´ëÇÐ Åä¸ñ°øÇаú;(ÁÖ)´ë¿ì°Ç¼³ Åä¸ñ±â¼ú2ÆÀ;(ÁÖ)ÆòÈ­¿£Áö´Ï¾î¸µ Áö¹Ý°øÇкÎ;
 
ÃÊ ·Ï
º» ¿¬±¸¿¡¼­´Â »ç¸é¾ÈÁ¤ È®º¸¸¦ À§ÇØ ¼³Ä¡µÈ ¾ïÁö¸»¶Ò°ú º¸°­»ç¸éÀÇ ¾ÈÀüÀ²À» »êÁ¤ÇÒ ¼ö ÀÖ´Â °£Æí¼³°è ¹ýÀ» Á¦¾ÈÇÏ¿´´Ù. ¾ïÁö¸»¶Ò-Áö¹Ý°£ »óÈ£ÀÛ¿ëÀº ÇÏÁßÀüÀ̹ýÀ¸·Î, »ç¸éÀÇ ¾ÈÀüÀ²Àº BishopÀÇ °£Æí¹ýÀ» ÀÌ¿ëÇÏ¿© »êÁ¤ÇÏ¿´´Ù. ¸»¶Ò °£°Ý¿¡ µû¸¥ ±º¸»¶Ò È¿°ú¸¦ °í·ÁÇϱâ À§ÇØ ½Ç³»¸ðÇü½ÇÇè ¹× À¯ÇÑ¿ä¼ÒÇØ¼®À» ¼öÇàÇÏ¿´À¸¸ç ÀÌ °á°ú¸¦ Åä´ë·Î ±º¸»¶Ò »óÈ£ÀÛ¿ë°è¼ö¸¦ Á¦¾ÈÇÏ¿´´Ù. Á¦¾ÈµÈ ±º¸»¶Ò »óÈ£ÀÛ¿ë°è¼ö´Â ¸»¶ÒÁ߽ɰ£°ÝÀÌ Á¼¾ÆÁú¼ö·Ï °¨¼ÒÇÏ¿´À¸¸ç, µÎºÎÁ¶°ÇÀÌ ÀÚÀ¯´ÜÀÎ °æ¿ì°¡ ´Ù¸¥ ±¸¼ÓÁ¶°Ç¿¡ ºñÇØ Å« ÆøÀ¸·Î °¨¼ÒÇÏ¿´´Ù. °³¹ßµÈ ¾ïÁö¸»¶ÒÀÇ ¼³°è±â¹ýÀº º» ¿¬±¸¿¡¼­ ¼öÇàÇÑ ¿ø½É¸ðÇü½ÇÇè, ÇöÀå½ÃÇè ¹× ±âÁ¸ À¯ÇÑ¿ä¼ÒÇØ¼®°á°ú¿Í ºñ±³.ºÐ¼®ÇÏ¿´´Ù. º» ÇØ¼®ÇÁ·Î±×·¥Àº 3Â÷¿ø À¯ÇÑ¿ä¼ÒÇØ¼®¿¡ ºñÇØ ½±°í °£´ÜÇϸ鼭µµ ¸»¶Ò-Áö¹Ý°£ »óÈ£ÀÛ¿ë¿¡ ÀÇÇØ ¸Å¿ì º¹ÀâÇÑ °Åµ¿À» ³ªÅ¸³»´Â ¾ïÁö¸»¶ÒÀ» ºñ±³Àû ÀûÀýÈ÷ ¼³°è ÇÒ ¼ö ÀÖÀ½À» ¾Ë ¼ö ÀÖ¾ú´Ù.
This paper describes a simplified design method of stabilizing piles based on an experimental tests and an analytical study which can take into account the safety factor of slope and pile spacing. The nonlinear characteristics of the soil-pile interaction for stabilizing piles are modeled by using load transfer method. The interaction factors due to pile spacing and cap rigidity were estimated by using a three dimensional nonlinear finite element approach and laboratory tests. Based on the results obtained, the interaction factors are proposed quantitatively for one-row pile groups with spacing-to-diameter ratios varying far 2.5 to 7.0. The Bishop's simplified method of slope stability analysis is extended to incorporate the soil-pile interaction and determine the safety factor of the reinforced slope. Through the comparative study, it is found that the prediction by present approach is in relatively good agreement with the results of centrifuge tests and field tests and three dimensional finite element analyses.
 
Ű¿öµå
Group interaction factor;Simplified design method;Stabilizing pile;Three-dimensional finite element analyses;
 