¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹Áö¹Ý°øÇÐȸ / v.17, no.6, 2001³â, pp.225-233
Àü±âÀúÇ× ÃøÁ¤±â¹ýÀ» ÀÌ¿ëÇÑ ¿À¿°¹°Áú ´©Ãâ°¨Áö½Ã½ºÅÛÀÇ °³¹ß: II. ÇöÀå¸ðÇü½ÃÇèÀ» ÅëÇÑ ¸Å¸³Áö¿¡ÀÇ Àû¿ë¼º Æò°¡
( Development of Contaminant Leakage Detection System Using Electrical Resistance Measurement: ll. Evaluation of Applicability for Landfill Site by Field Model Tests )
¿À¸íÇÐ;ÀÌÁÖÇü;¹ÚÁعü;±èÇü¼®;°­¿ì½Ä; ¼­¿ï´ëÇб³ Áö±¸È¯°æ½Ã½ºÅÛ°øÇкÎ;¼­¿ï´ëÇб³ Áö±¸È¯°æ½Ã½ºÅÛ°øÇкÎ;¼­¿ï´ëÇб³ Áö±¸È¯°æ½Ã½ºÅÛ°øÇкÎ;¼øÃµÇâ´ëÇб³ Á¤º¸±â¼ú°øÇкÎ;(ÁÖ)Áø¿ì±â¼ú;
 
ÃÊ ·Ï
º» ³í¹®¿¡¼­´Â °ÝÀÚ¸Á½Ä Àü¼±¹èÄ¡¿¡ ÀÇÇÑ Ä§Ãâ¼ö ´©Ãâ°¨Áö½Ã½ºÅÛÀ» °³¹ßÇϱâ À§ÇÏ¿© ÇöÀå¸ðÇü½ÃÇèÀ» ÅëÇÏ¿© Àû¿ë¼ºÀ» Æò°¡ÇÏ¿´À¸¸ç, Àü±âȸ·Î½ÃÇèÀ» ÅëÇÏ¿© °ÝÀÚ¸Á Àü¼± ¹èÄ¡¿¡¼­ ¹ß»ýÇÏ´Â Àü±âȸ·ÎÀû È¿°ú¸¦ ÆÄ¾ÇÇϰíÀÚ ÇÏ¿´´Ù. ħÃâ¼ö´Â Àü±âÀúÇ×À» °¨¼Ò½Ã۱⠶§¹®¿¡ ´©ÃâÁöÁ¡¿¡¼­´Â ´Ù¸¥ ÁöÁ¡¿¡ ºñÇØ ³·Àº Àü±âÀúÇ×°ªÀ» ³ªÅ¸³»¾ú´Ù. µû¶ó¼­, Àü±âÀúÇ×À» ÃøÁ¤ÇÏ´Â º» ´©Ãâ°¨Áö½Ã½ºÅÛ¿¡ ÀÇÇÏ¿© ÀÓÀÇ ÁöÁ¡¿¡¼­ ¹ß»ýÇϴ ħÃâ¼öÀÇ ´©Ãâ °¨Áö°¡ °¡´ÉÇÏ¿´À¸¸ç, Æò¸éÀû ºÐÆ÷µµ¸¦ ÅëÇÏ¿© ´©ÃâÀ§Ä¡ÀÇ ÆÄ¾ÇÀÌ °¡´ÉÇÏ¿´´Ù. Àü±âÀúÇ×ÀÌ °¨¼ÒµÈ ÁöÁ¡°ú µ¿ÀÏÇÑ Àü¼±»ó¿¡ À§Ä¡ÇÑ ´Ù¸¥ ¼¾¼­¿¡ ¼­ÀÇ ÃøÁ¤°ªµµ ¾à°£ °¨¼ÒÇÏ´Â °æÇâÀ» ³ªÅ¸³»¾úÀ¸³ª, ÀÌ´Â ÀúÇ×ÀÌ ÀÛÀº °÷À¸·Î Àü·ùÀÇ È帧ÀÌ ¹ß»ýÇÏ´Â Àü±âȸ·ÎÀû È¿°ú·Î ¼³¸íÇÒ ¼ö ÀÖ¾ú´Ù.
Field model tests were performed to develop the grid-net landfill leachate leakage detection system using electrical resistance. Electric circuit tests were also carried out to investigate the expected electrical effects of grid-net electric circuit. The resistance of leaking point showed lower value than that of non leaking point. Grid-net leakage detection system was thought to be effective to locate the leachate leaking point. The measured electrical resistance along the wire including the leaking point was slightly reduced following the reduction of electrical resistance at the leaking point, which was explained by electric circuit test results.
 
Ű¿öµå
Electrical conductance;Electrical resistance;Electric circuit;Leachate;Leak detection;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.17, no.6, 2001³â, pp.225-233
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200111920879685)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿