¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹Áö¹Ý°øÇÐȸ / v.23, no.8, 2007³â, pp.47-57
Áؼ³¸Å¸³Áö¹ÝÀÇ ¾×»óÈ­ °£Æí¿¹Ãø °³¼±¿¡ °üÇÑ ¿¬±¸
( Improvement Scheme of Simplified Liquefaction Potential Evaluation for a Dredged and Reclaimed Ground )
Á¤¹ÎÇü;±èÁÖÇö;Á¤»ó±¹;À̼Û; ¼­¿ï½Ã¸³´ëÇб³ Åä¸ñ°øÇаú;¾ËÁö¿ÀÀÌ¿£¾¾;¼Û¿ø´ëÇÐ Åä¸ñ°è¿­;¼­¿ï½Ã¸³´ëÇб³ Åä¸ñ°øÇаú;
 
ÃÊ ·Ï
º» ¿¬±¸´Â »çÁúÅä·Î Áؼ³¸Å¸³µÈ Áö¹ÝÀÇ ¾×»óÈ­ Æò°¡¸¦ À§ÇØ ¹Ýµå½Ã ¿ä±¸µÇ´Â Ãʱ⠹еµÆ¯¼ºÀ» ºÐ¼®ÇÏ¿´°í, ±¹³» ³»Áø ¼³°è±âÁØ¿¡¼­ Á¦½ÃÇÑ SPT-NÀ» ÀÌ¿ëÇÑ ¾×»óÈ­ °£Æí¿¹Ãø ¹æ¹ýÀÇ ¹®Á¦Á¡À» ºÐ¼®ÇÏ¿© °³¼±¹æ¾ÈÀ» Á¦½ÃÇÏ¿´´Ù. ±âÁ¸ ½Ã°ø»ç·Ê¸¦ Åä´ë·Î ¸Å¸³ Á÷ÈÄ Áؼ³¸Å¸³Áö¹ÝÀÇ ¹ÐµµÆ¯¼ºÀ» ºÐ¼®ÇÑ °á°ú, »ó´ë¹Ðµµ¿Í Ãʱâ N°ªÀº ´ëü·Î °¢°¢ $40{sim}50%,;5{sim}8$ÀÇ ¹üÀ§¿¡ ºÐÆ÷ÇÏ¿´´Ù. ¾×»óÈ­ °£Æí¿¹Ãø¿¡ À־ À¯È¿»óÀç¾Ð º¸Á¤ÀÇ Liao & whitman½ÄÀº Ç×»ó ÁöÁø¿¡ Ãë¾àÇÑ »óºÎÃþÀÌ ÇϺÎÃþº¸´Ù ¾×»óÈ­ ÀúÇ×ÀÀ·ÂÀÌ Å©°Ô »êÁ¤µÇ¾î Skempton½ÄÀÇ Àû¿ëÀÌ ÃßõµÈ´Ù. ¶ÇÇÑ, ¼³°è´Ü°è¿¡¼­ Áؼ³¸Å¸³ Áö¹ÝÀÇ ½Éµµº° N°ªÀ» »êÁ¤ÇÒ °æ¿ì¿¡´Â, À¯È¿ÀÀ·Â¿¡ µû¸¥ N°ªÀÇ º¯È­¸¦ ³ªÅ¸³»´Â ´©½ÂÇÔ¼ö $N=1.35{sigma}^{'0.75}$¸¦ ÀÌ¿ëÇÏ¿© ¾×»óÈ­ °£Æí¿¹ÃøÀ» ½Ç½ÃÇÒ °ÍÀ» ÃßõÇÑ´Ù.
In this study, the analysis of density characteristics of some dredged and reclaimed ground sites, which is necessary for liquefaction evaluation of a dredged and reclaimed ground, was conducted. From analyzing a simplified liquefaction potential evaluation using SPT-N values which have been applied as domestic earthquake-resistant design criterion, improvement scheme is suggested. Based on the analysis result of density characteristics, it was found out that the relative density and the intial N-value ranged respectively $40{sim}50%;and;5{sim}8$. In the case of applying Liao & Whitman's equation to correct effective overburden pressure, liquefaction resistance of the upper ground that is relatively weaker than that of lower ground is overestimated. So, Skempton's equation is recommended. And the N value with depth which is applied for design process should be estimated by the exponential equation, $N=1.35{sigma}'^{0.75}$.
 
Ű¿öµå
Correction effective overburden pressure;Initial N value;Liquefaction potential evaluation;Liquefaction resistance;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.23, no.8, 2007³â, pp.47-57
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200734516348553)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿