¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹Áö¹Ý°øÇÐȸ / v.23, no.5, 2007³â, pp.43-51
Áö¹ÝÀÇ µ¿»ó·Â°ú ±¸Á¶¹°ÀÇ ÇÇÇØ´ëÃ¥
( Frost Heave Force of Ground and Countermeasure for Damage of Structures )
¿¹´ëÈ£;¿µ¸ñÈÖÁö;±è¿µ¼ö; ±âŸ¹Ì°ø¾÷´ëÇÐ Åä¸ñ°³¹ß°øÇаú;±âŸ¹Ì°ø¾÷´ëÇÐ Åä¸ñ°³¹ß°øÇаú;°æºÏ´ëÇб³ Åä¸ñ°øÇаú;
 
ÃÊ ·Ï
µ¿°áÀÛ¿ëÀº ºôµù, ±¸Á¶¹°, µµ·Î, öµµ ±×¸®°í °ø°ø½Ã¼³°ü·Î¿¡ ¾öû³­ ¼Õ»óÀ» ÀÏÀ¸Å³ °ÍÀÌ´Ù. ÀÚ¿¬Áö¹ÝÀÇ µ¿»ó¿¡ ´ëÇÑ ¿¬±¸´Â °ú°Å¿¡ ¸¹ÀÌ ¼öÇàµÇ¾ú´Ù. ±Ù·¡¿¡´Â »çȸ±â¹Ý½Ã¼³ À¯ÁöÀÇ ¹ßÀü°ú ÇÔ²² °¢Á¾±¸Á¶¹°ÀÇ º¹ÀâÈ­·Î ÀÎÇÏ¿© µ¿»ó´ëÃ¥¿¡ ´ëÇÑ °ü½ÉÀÌ ÁýÁߵǰí ÀÖ´Ù. º» ¿¬±¸¿¡¼­´Â ±¸Á¶¹°¿¡ ÀÛ¿ëÇÏ´Â ÀÚ¿¬Áö¹ÝÀÇ µ¿»ó·ÂÀ» Á¤·®ÀûÀ¸·Î ÆÄ¾ÇÇÏ´Â °ÍÀ» ¸ñÀûÀ¸·Î ÇÏ¿´´Ù. ÁöÇ¥¸é¿¡ ¼³Ä¡ÇÑ ¿øÇü°­ÆÇ¿¡ ÀÛ¿ëÇÏ´Â µ¿»ó·ÂÀÌ ÇöÀå½ÃÇè¿¡¼­ ÃøÁ¤µÇ¾ú´Ù. µ¿°á¸é¿¡¼­ ¹ß»ýÇÏ´Â µ¿»ó·ÂÀº µ¿°áµÈ ÅäÃþÀ» °ÅÃÄ ±¸Á¶¹°¿¡ Àü´ÞµÈ´Ù. ¶ÇÇÑ ´Ù´Ü¾ÞÄ¿·Î º¸°­µÈ ¿Ëº®ÀÌ ÇöÀå¿¡ ¼³Ä¡µÇ°í ¿Ëº®¿¡ ÀÛ¿ëÇÏ´Â µ¿°á¼±°ú µ¿»ó¾Ð µîÀÌ ÃøÁ¤µÇ¾ú´Ù. ÃÖÁ¾ÀûÀ¸·Î µ¿°á¸éÀÇ À§Ä¡¿Í Çü»óÀÌ ¼öÄ¡ÇØ¼®¼ö¹ýÀ» ÀÌ¿ëÇÏ¿© ÃßÁ¤µÇ¾ú°í ġȯ ¹üÀ§¸¦ °áÁ¤ÇÏ´Â ¼³°è¼ö¹ýÀÌ ÅäÁúÁ¤º¸¿Í ±â»óÁ¤º¸¿¡ µû¶ó Á¦¾ÈµÇ¾ú´Ù.
Frost action may cause extensive damage to building, structures, roads, railways and utility lines in seasonal frost. The research about frost heave of natural ground has been considerably performed. In late years various structures have become complicated with the development of social infrastructure maintenance. Therefore countermeasure to frost heave becomes a matter of great importance from a new viewpoint. This study was aimed at catching natural ground frost heaving force quantitatively. Frost heaving forces on circular steel plates which were set on ground surface were measured in field test. The frost heaving forces arise at freezing front propagates to the structures through frozen soil layer. Besides, a full scale model of multi-anchored retaining wall was installed in field, and the freezing lines, frost heave pressure to act on a wall block, and so on were measured. Finally, the position and shape of frost line were estimated by using numerical simulation and a method to determine replacement range was suggested with soil properties and weather data.
 
Ű¿öµå
Frost heave force;Multi-anchored retaining wall;Numerical simulation;Replacement method;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.23, no.5, 2007³â, pp.43-51
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200724737435046)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿