Çѱ¹Áö¹Ý°øÇÐȸ / v.19, no.5, 2003³â, pp.35-47
º¯ÇüºÀ ¼¾¼­ °ËÁõ½ÇÇè¿¡ °üÇÑ ¿¬±¸
( A Study on the Verification Test for a Deformable Rod Sensor )
±è»óÀÏ;ÃÖ¿ë±Ô;À̹ÎÈñ; (ÁÖ)»óÁö¿£Áö´Ï¾î¸µ °ÇÃà»ç»ç¹«¼Ò;°æ¼º´ëÇб³ °Ç¼³¡¤È¯°æ°øÇкÎ;ºÎ»ê´ëÇб³ ´ëÇпø Åä¸ñ°øÇаú;
 
ÃÊ ·Ï
³»ºÎ¸¦ ÄÜÅ©¸®Æ®·Î ¼Óä¿òÇÑ °­°üÇÕ¼º¸»¶Ò¿¡ ´ëÇÑ ±âÁ¸ÀÇ ÇÏÁßÀüÀÌ ÃøÁ¤¿¡¼­´Â °­°üÀÇ º¯Çü·ü¸¸ ÃøÁ¤Çϰí ÄÜÅ©¸®Æ®ÀÇ º¯Çü·üÀº °­°ü°ú µ¿ÀÏÇÏ´Ù°í °¡Á¤ÇÏ¿´À¸¸ç, ½Ã¹æ¼­¿¡ ±ÔÁ¤ÇÑ ¹æ¹ýÀ¸·Î ±¸ÇÑ °­°ü°ú ÄÜÅ©¸®Æ®ÀÇ Åº¼º°è¼ö¸¦ ÀÌ¿ëÇÏ¿© ¸»¶Ò±¸¼ººÎÀçÀÇ ÀÀ·Â ¹× ÃàÇÏÁßÀ» »êÁ¤ÇÏ¿´´Ù. ±×·¯³ª °­°üÀÇ º¯Çü·ü¸¸ ÃøÁ¤ÇÏ¿© °­°ü°ú ÄÜÅ©¸®Æ®°¡ ¿ÏÀüÇÕ¼º °Åµ¿ÇÏ´Â °ÍÀ¸·Î »êÁ¤ÇÑ ÃàÇÏÁßÀº ½ÇÁ¦ ÇÏÁß°ª°ú »ó´çÇÑ Â÷À̸¦ º¸À̰í ÀÖ¾î °­°üÇÕ¼º¸»¶ÒÀÇ °Åµ¿À» Á¤È®È÷ ºÐ¼®ÇÒ ¼ö ¾ø¾ú´Ù. µû¶ó¼­, °­°üÇÕ¼º¸»¶ÒÀÇ °æ¿ì °¢ ±¸¼ººÎÀçÀÇ º¯Çü·üÀ» ÃøÁ¤ÇÒ Çʿ伺ÀÌ Á¦±âµÇ¾ú´Ù. º» ¿¬±¸¿¡¼­´Â °­°üÇÕ¼º¸»¶ÒÀÇ ±¸¼ººÎÀçÀÎ °­Àç¿Í ÄÜÅ©¸®Æ®ÀÇ º¯Çü·üÀ» ÃøÁ¤Çϴµ¥ »ç¿ëÇÒ ¼ö ÀÖµµ·Ï °³¹ßµÈ º¯ÇüºÀ ¼¾¼­¿¡ ´ëÇÑ °ËÁõ½ÇÇèÀ» ¼öÇàÇÏ¿´´Ù º¯ÇüºÀ ¼¾¼­¸¦ »ç¿ëÇÏ¿© ¸»¶ÒÃàÇÏÁßÀ» »êÁ¤ÇÒ °æ¿ì ÄÜÅ©¸®Æ®ÀÇ Åº¼º°è¼ö´Â ÇöÀå¿¡¼­ Á¦ÀÛÇÑ ÄÜÅ©¸®Æ® °ø½ÃüÀÇ ¾ÐÃà°­µµ ½ÃÇè¿¡¼­ ±¸Çϵµ·Ï Á¦¾ÈÇÏ¿´´Ù. Áï, (0.2¡­0.6)f$_ck$ÀÇ ÀÀ·Â ¹üÀ§¿¡ ÇØ´çÇÏ´Â Æò±ÕÁ¢¼±±â¿ï±â¸¦ ź¼º°è¼ö·Î »ç¿ëÇϵµ·Ï Á¦¾ÈÇÏ¿´´Ù.
In the conventional axial load transfer analysis for composite piles (i.e., steel pipe pile filled with concrete), it was assumed that the concrete's strain is same as the measured steel's strain and the elastic modulus of the steel and the concrete calculated by formular as prescribed by specification is used in calculation of pile axial load. But, the pile axial load calculated by conventional method had some difference with the actual pile load. So, the behavior of a composite pile could not be analyzed exactly. Thus, the necessity to measure the strain for each pile components was proposed. In this study, the verification test for DRS (Deformable Rod Sensor) developed to measure the strain of each pile component (i.e., the steel and the concrete) was performed. In the calculation of pile axial load using the DRS, elastic modulus of concrete could be determined by the uniaxial compression test for the concrete cylinder samples made in the test site and an average tangential modulus in the stress range of (0.2¡­0.6)f$_ck$ was taken.
 
Ű¿öµå
Average tangential modulus;Composite pipe pile;DRS (Deformable Rod Sensor);Elastic modulus;Pile axial load distribution;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.19, no.5, 2003³â, pp.35-47
Çѱ¹Áö¹Ý°øÇÐȸ
ISSN : 1229-2427
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200311921979047)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø