Çѱ¹Áö¹Ý°øÇÐȸ / v.26, no.11, 2010³â, pp.111-123
¸»¶Ò ÀçÇϽÃÇèÀ» ÀÌ¿ëÇÑ °­°üÇÕ¼º ÇöÀ埼³¸»¶ÒÀÇ Àû¿ë¼º ºÐ¼®
( Applicability of Steel-Concrete Composite Drilled Shafts by Pile Loading Tests )
ÀÌÁÖÇü;Á¤¹®°æ;°û±â¼®;±è¼º·Ä; Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø Áö¹Ý¿¬±¸½Ç;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø Áö¹Ý¿¬±¸½Ç;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ±âȹÁ¶Á¤Ã³;µ¿¾Æ´ëÇб³ Åä¸ñ°øÇаú;
 
ÃÊ ·Ï
°­°üÇÕ¼º ÇöÀ埼³¸»¶ÒÀº ±¼Âø½Ã °øº®º¸È£¸¦ À§ÇØ »ç¿ëµÇ´Â °­°üÄÉÀ̽ÌÀ» ±¸Á¶Àç·Î º¸°í ³»ºÎ¿¡ ÄÜÅ©¸®Æ®¸¦ ä¿î ÇÕ¼º¸»¶ÒÀ¸·Î¼­ ¿ÜºÎ °­°üÀÌ ³»ºÎ ÄÜÅ©¸®Æ®ÀÇ º¯ÇüÀ» ¾ïÁ¦ÇÏ¿© ¸»¶ÒÀÇ °­µµ¸¦ Áõ°¡½ÃŰ°í ¿¬¼ºÆÄ±«¸¦ À¯µµÇÏ´Â º¸°­ È¿°ú¸¦ ¹ßÈÖÇÑ´Ù. º» ¿¬±¸¿¡¼­´Â °­°üÇÕ¼º ÇöÀ埼³¸»¶ÒÀÇ ÇöÀå Àû¿ë¼ºÀ» ºÐ¼®Çϱâ À§ÇÏ¿© ÇöÀåÀçÇϽÃÇèÀ» ¼öÇàÇÏ¿´´Ù. ½ÃÇè°á°ú °­°ü ¼±´ÜºÎ Áï, °­°üÇÕ¼º-ÄÜÅ©¸®Æ® °æ°è¸éÀÌ ±¸Á¶ÀûÀ¸·Î Ãë¾àÇϸç ÈÚ¿¡ ´ëÇÑ ÀúÇ×·ÂÀÌ À۱⠶§¹®¿¡ ³»ºÎ ö±Ù¸ÁÀ» ¼³Ä¡ÇÏ¿© ÀÌ ºÎºÐÀ» º¸°­ÇÒ Çʿ䰡 ÀÖ¾ú´Ù. ¶ÇÇÑ °­°üÇÕ¼º-ÄÜÅ©¸®Æ® °æ°è¸éÀÌ ÈÚ¸ð¸àÆ®ÀÇ ¿µÇâÀ» ¹ÞÁö ¾Ê´Â ÃæºÐÈ÷ °±Àº ±íÀÌ¿¡ À§Ä¡Çϰí ÁÖº¯Áö¹ÝÀÇ ±¸¼ÓÈ¿°ú°¡ ¹ßÈֵǴ °æ¿ì¿¡´Â °­°üÇÕ¼º ÇöÀ埼³¸»¶ÒÀÇ ÇϺΠÄÜÅ©¸®Æ® Àç·á¿¡ ´ëÇÑ Çã¿ë°­µµ°¡ Áõ°¡ÇϹǷΠ°­°üÇÕ¼º ÇöÀ埼³¸»¶ÒÀÇ ¼³°èÇÏÁßÀ» Áõ°¡½ÃÄÑ °æÁ¦ÀûÀÎ ¼³°è°¡ ±â´ÉÇØÁú ¼ö ÀÖÀ» °ÍÀ¸·Î ÆÇ´ÜµÈ´Ù.
The steel pipe of steel-concrete composite drilled shafts increases the pile strength and induces the ductile failure by constraining the deformation of the inner concrete. In this research, pile loading tests were performed to analyze the field applicability of a steel-concrete composite drilled shafts. The test ground consisted of 5~7 m thick soil underlying rock mass. The test piles consisted of two steel-concrete composite drilled shafts, which were the concrete filled steel pipe piles with the diameter of 0.508 m, and a concrete pile with the same diameter. The test results showed that the boundary between the upper steel composite section and the lower concrete section was structurally weak and needs to be reinforced by using a inner steel cage. If the boundary is located in deep depth, which is not influenced by lateral load, the allowable strength of the lower concrete section increases, so an economical design can be performed by increasing the design load of steel-concrete composite drilled shafts.
 
Ű¿öµå
Composite pile;Drilled shaft;Pile loading test;Pile material strength;Steel-concrete composite drilled shafts;
 