Çѱ¹°ÇÃà½Ã°øÇÐȸ / v.10, no.3, 2010³â, pp.129-136
°³Æó½Ä ´ë°ø°£ ¸· ±¸Á¶¹°¿¡¼­ ÁöºØ ¸Â´ïºÎ ¿ì¼öÂ÷´Ü ½Ã½ºÅÛÀÇ ¼ö¹Ð¼º Æò°¡¿¡ °üÇÑ ¿¬±¸
( A Study on the Evaluation of Watertightness Properties for Rain-Block System in the Sliding-Roof Joint of Large-Span Membrane Structures )
¿À»ó±Ù;¹é±â¿­;À̼±±Ô; ¼­¿ï»ê¾÷´ëÇб³ °ø°ú´ëÇÐ °ÇÃàÇкÎ;(ÁÖ)CS±¸Á¶¿£Áö´Ï¾î¸µ ±â¼ú¿¬±¸¼Ò;BK¹æ¼ö±â¼ú¿¬±¸¼Ò;
 
ÃÊ ·Ï
ÁöºØ °³ÆóÇüÅÂÀÇ ´ë°ø°£ ¸· ±¸Á¶¹°Àº ¸ÖƼ¹Ìµð¾îÀûÀÎ ¿ä¼Ò ¹× ÀüõÈÄ °ø°£À» Ȱ¿ëÇÒ ¼ö ÀÖÁö¸¸, ´Ù¼öÀÇ ¿¬°á Á¶ÀÎÆ®¿¡ ÀÇÇØ ±¸Á¶¹°ÀÌ Çü¼ºµÇ¹Ç·Î ´©¼ö¿¡ Ãë¾àÇÑ ¹®Á¦Á¡ÀÌ ÀÖ´Ù. ƯÈ÷ °³Æó½Ä ÁöºØ ¸Â´ïºÎÀ§ÀÇ ¿ì¼öÂ÷´Ü ½Ã½ºÅÛÀº ¿ì¼öÀÇ Á÷Á¢ÀûÀÎ À¯ÀÔÀ» Â÷´ÜÇÏ´Â ¿ªÇÒÀ» Çϰí ÀÖÀ¸¹Ç·Î ¹Ù¶÷À» µ¿¹ÝÇÑ °­¿ìȯ°æ¿¡¼­µµ ¼ö¹Ð¼º´ÉÀÌ ¿ä±¸µÈ´Ù. µû¶ó¼­ »ó±âÀÇ È¯°æ Á¶°ÇÀ» ºÎ¿©ÇÑ ¼ö¹Ð¼º ½ÇÇèÀ» ÅëÇÏ¿© ¿ì¼öÂ÷´Ü ½Ã½ºÅÛÀÇ µðÅ×ÀÏ¿¡ ´ëÇÑ ¼ö¹Ð¼º´ÉÀ» Æò°¡ÇϰíÀÚ ÇÑ´Ù. ½ÇÇè °á°ú, ¸ðµç ½ÇÇèü¿¡¼­ ´©¼ö°¡ ¹ß»ýÇÏ¿´À¸¸ç, ¿ì¼öÀÇ À¯ÀÔ°æ·Î´Â µ¿ÀÏÇÑ °ÍÀ¸·Î È®ÀεǾú´Ù. ƯÈ÷, ¹Ù¶÷¿¡ ÀÇÇÏ¿© ¹°ÀÔÀÚµéÀÌ ±¸Á¶¹° ³»ºÎ·Î µéÀÌÄ¡´Â Çö»óÀÌ ÁÖ¿øÀÎÀ̹ǷΠÀ̸¦ º¸¿ÏÇÑ »õ·Î¿î ¿ì¼öÂ÷´Ü ½Ã½ºÅÛÀÇ µðÅ×ÀÏÀÌ ¿ä±¸µÈ´Ù. ÀÌ ¿¬±¸¸¦ ÅëÇØ °­¿ì ȯ°æ°ú ¹Ù¶÷ ȯ°æÀ» µ¿½Ã¿¡ ºÎ¿©ÇÏ¿´À» ¶§ ¹ß»ýµÉ ¼ö ÀÖ´Â ¿ì¼ö ħÀÔ °æ·Î¸¦ È®ÀÎÇÏ¿´À¸¸ç, ¼ö¹Ð ¼º´É È®º¸ À¯¹«°¡ »çÀü¿¡ °ËÅäµÇ¾î Á®¾ßÇÔÀ» ¾Ë ¼ö ÀÖ¾ú´Ù. ¶ÇÇÑ, µðÅ×ÀÏÀ» »çÀü¿¡ ÀÛ¼ºÇÏ¿© ¸ðÇü ¼ö¹Ð¼º ½ÃÇèÀ» ¹Ýµå½Ã ½ÃÇàÇÑ ÈÄ ±× °á°ú¿¡ µû¶ó ¼³°è µðÅ×ÀÏÀÇ º¯°æ, °³¼±, º¸¿Ï½Ã°øÀ» ÇÏ¿©¾ß ÇÒ °ÍÀÌ´Ù.
This study is an evaluation of the water-tightness properties of rain-block systems in the sliding-roof joint of large-span membrane structures. In this study, we suggested a method of evaluating the water-tightness performance of the joint part of a sliding door in the roof of a large-span membrane structure (for a pilot project), in an environment of rain and wind. The shape of the rainwater blocking systems of the joint part in a sliding door verifies the defects and the effects of water leakage prevention when there is precipitation with wind conditions. To secure the water-tightness of large span membrane structures, it is necessary to have a guideline on the evaluation of the design for rain-block system of the joint part, and the quality of the membrane material, both of a retractable roof and a closed roof.
 
Ű¿öµå
°³Æó½Ä ÁöºØ;ÁöºØ ¸Â´ï ºÎÀ§ÀÇ ¿ì¼öÂ÷´Ü ½Ã½ºÅÛ;¼ö¹Ð¼º ½ÇÇè;¹Ù¶÷À» µ¿¹ÝÇÑ °­¿ìȯ°æ;large span membrane structures;sliding-roof;rain-block system;watertightness properties;
 