Çѱ¹Áö¹Ý°øÇÐȸ / v.27, no.8, 2011³â, pp.39-50
¸»¶Ò °£°Ý¿¡ µû¸¥ ¿¡³ÊÁö ÆÄÀÏÀÇ ¿­Àû °Åµ¿ºÐ¼®
( Effect of Group Spacing of Energy Piles on Thermal Analysis )
¹ÎÇý¼±;À±Å¼·;Á¤»ó¼¶; ¿¬¼¼´ëÇб³ Åä¸ñȯ°æ°øÇаú;¿¬¼¼´ëÇб³ Åä¸ñȯ°æ°øÇаú;¿¬¼¼´ëÇб³ Åä¸ñȯ°æ°øÇаú;
 
ÃÊ ·Ï
º» ³í¹®¿¡¼­´Â Áö¿­À» ÀÌ¿ëÇÑ PHC ¸»¶ÒÇü ¿¡³ÊÁö ÆÄÀÏÀÇ °èÀýº° À¯¼Óº¯È­¿¡ µû¸¥ ¿­±³È¯À²°ú ´Üµ¶¸»¶ÒÀÇ ¿­±³È¯À²À» 100½Ã°£ ¿î¿ë ½Ã Æ÷È­Áö¹Ý Á¶°Ç¿¡ ÇÑÁ¤ÇÏ¿© ¼öÄ¡ÇØ¼®À» ¼öÇàÇÏ¿´´Ù. ÇØ¼®°á°ú µ¿Àý±â ¹× ÇÏÀý±âÀÏ ¶§ 100½Ã°£ ¿î¿ë ½Ã Æò±Õ ¿­±³È¯À²Àº ¾à 55 W/m, 47 W/m·Î ³ªÅ¸³µÀ¸¸ç, ¼øÈ¯¼ö À¯¼ÓÀÌ Áõ°¡ÇÒ¼ö·Ï ÀüüÀûÀÎ ¿­±³È¯À²ÀÌ »ó½ÂÇÏ¿´´Ù. µ¿Àý±â¿¡ ¸»¶Ò°£°Ý 3D ¹× 5D(D:¸»¶ÒÁ÷°æ) ¹èÄ¡ ½Ã 0.6m/sÀÇ ¼øÈ¯¼ö À¯¼Ó¿¡ µû¸¥ ¿­Àû°Åµ¿À» ºÐ¼®°á°ú Áö¹Ý°úÀÇ ¿­Àû ÀÚÀ¯¸éÀÌ ¸¹Àº ¿Ü°ûºÎÀϼö·Ï ¿­È¿À²ÀÌ Áõ°¡ÇÏ¿´´Ù. ¶ÇÇÑ, 3D ¹× 5D °£°ÝÀÇ Æò±Õ ¿­±³È¯À²Àº ¾à 48.5 W/m, 51 W/m·Î ¸»¶Ò°£°ÝÀÌ Áõ°¡ÇÒ¼ö·Ï ¿­±³È¯À²ÀÌ Çâ»óµÇ´Â °ÍÀ¸·Î ³ªÅ¸³µÀ¸¸ç, ´Üµ¶¸»¶ÒÀÇ ¿­±³È¯À² ´ëºñ »ó´ëÀûÀ¸·Î 3D ¹× 5D °£°ÝÀÇ ±º¸»¶ÒÀº °¢°¢ 89% ¹× 93%º¸ ¶³¾îÁö´Â °ÍÀ» ¾Ë ¼ö ÀÖ¾ú´Ù.
This study was conducted to analyze the thermal behavior of a PHC energy pi1e system in saturated soil conditions, various seasonal and flow-speed conditions during 100 hours of operation through numerical analysis. The examination was a1so conducted with a single pile as well as with group pils. For the operation of 100 hours, the average heat exchange rate appeared 55 W/m, 47 W/m during winter and summer respectively. An increase in flow-speed was associated with a rise in the heat exchange rate. And thermal behavior analysis results during winter season show that thermal efficiency has increased when there are more free thermal planes. For the operation in group pile as 3D and 5D pile spacing (D: pile diameter), average heat exchange rate increased as pile spacing grows. Compared with the heat exchange rate of single pile, thermal exchange efficiency of group pile decreased by 89% (for 3D spacing) and 93% (for 5D spacing).
 
Ű¿öµå
Energy piles;Group piles;Heat exchange rate;Thermal conductivity;
 
Çѱ¹Áö¹Ý°øÇÐȸ³í¹®Áý / v.27, no.8, 2011³â, pp.39-50