¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹°ÇÃà½Ã°øÇÐȸ / v.11, no.3, 2011³â, pp.229-237
ÄÜÅ©¸®Æ® °­µµÆò°¡¸¦ À§ÇÑ ÀιßÀåÄ¡¿Í ÈĸÅÀÔ Àιߺ¼Æ®ÀÇ °³¹ß
( Development of Post-installable Pullout Bolts and a Loading Device for Evaluating Concrete Strength )
°íÈÆ¹ü;À̰­;¿øÁ¾¼º; ;;;
 
ÃÊ ·Ï
Àι߹ýÀº ÄÜÅ©¸®Æ® °­µµ¸¦ ºñÆÄ±«ÀûÀ¸·Î ÃøÁ¤ÇÏ´Â ¹æ¹ýÀ¸·Î ¸Å¿ì ½Å·ÚÇÒ ¸¸ÇÑ ½ÇÇè°á°ú¸¦ º¸¿©ÁÖ°í ±¸¹Ì¿¡¼­´Â ±Ô°ÝÈ­µÇ°í Ç¥ÁØÈ­°¡ ÀÌ·ç¾îÁ® ÀÖ´Ù. ÇÏÁö¸¸ ½ÃÇè¹æ¹ýÀÌ º¹ÀâÇÏ°í ½ÃÇè±â±â°¡ °í°¡À̾ ±¹³»¿¡¼­´Â »ç¿ëÀÌ Àü¹«ÇÑ ½ÇÁ¤ÀÌ´Ù. ÀÌ¿¡ º» ¿¬±¸¿¡¼­´Â Àι߹ýÀÌ ÇöÀå¿¡¼­ »ç¿ëÇϱ⠽±µµ·Ï ½ÃÇè¹æ¹ýÀ» °£´ÜÈ÷ Çϰí Àú·ÅÇÏ°Ô ÇÒ ¼ö ÀÖµµ·Ï ÈĸÅÀÔ ÆÄ´ÜÇü Àιߺ¼Æ®¸¦ ÀÌ¿ëÇÑ Àι߽ÃÇè¹ýÀ» Á¦¾ÈÇÏ¿´À¸¸ç, ½ÃÇè¹ý¿¡ ÇÊ¿äÇÑ ÈĸÅÀÔ ÆÄ´ÜÇü Àιߺ¼Æ®¿Í ¸ÅÀÔÀÎ¹ß³ÊÆ® °íÁ¤¹æ¹ý, Àι߽ÃÇè±â¸¦ °³¹ßÇÏ¿´´Ù. ƯÈ÷ ¸ÅÀÔÀÎ¹ß³ÊÆ® °íÁ¤¹æ¹ýÀ¸·Î´Â ÀӽðíÁ¤¿ë º¼Æ®¸¦ ÀÌ¿ëÇÑ ¹æ¹ý, ÇÃ¶ó½ºÆ½ °íÁ¤ÆÇÀ» ÀÌ¿ëÇÑ ¹æ¹ý, °íÁ¤¸·´ë¸¦ ÀÌ¿ëÇÑ °íÁ¤¹æ¹ýÀ» Á¦¾ÈÇÏ¿´´Ù. Àι߽ÃÇè±â´Â À¯¾Ð½Ç¸°´õ¿Í ·Îµå¼¿ µîÀÌ ÇÊ¿ä ¾øµµ·Ï ±â¾î¸¦ ÀÌ¿ëÇÏ¿© ¼ÕÀâÀ̸¦ ÅëÇÑ È¸Àü·ÂÀ¸·Î Àι߽ÃÇèÀÌ °¡´ÉÇϵµ·Ï °í¾ÈÇÏ¿´´Ù. ÀÌ °³¹ßµÈ °¢°¢ÀÇ Ç׸ñµéÀº Á÷Á¢ Á¦ÀÛÇϰí ÇöÀå¿¡¼­ ±× Æí¸®¼º°ú Á¤È®¼ºÀ» °ËÅäÇØ º¸¾ÒÀ¸¸ç °ËÁõ½ÇÇèµµ ½Ç½ÃÇÏ¿´´Ù. °á°úÀûÀ¸·Î °³¹ßµÈ Ç׸ñµéÀº Ãß°¡ÀûÀÎ ¼öÁ¤¸¸ °ÅÄ¡¸é ÇöÀå¿¡¼­ À¯¿ëÇÏ°Ô »ç¿ëÇÒ ¼ö ÀÖÀ¸¸®¶ó ÆÇ´ÜµÈ´Ù.
The pullout test is a nondestructive testing method certified by the American Society for Testing and Materials (ASTM) and British Standards (BS). Research has shown that it is very reliable in terms of evaluating the concrete strength of reinforced concrete members. However, the pullout test is rarely performed on domestic construction sites due to the complex procedures and high costs involved. This study proposes a new pullout test composed of a post installable break-off bolt, an insert nut, and a pullout tester, which satisfy both economical and practical purposes on a construction site. Three different types of special fastening methods, a temporary fixed bolt, a plastic fixed panel, and a fixed bar, have been developed. A pullout tester is proposed that is driven by the circle force introduced into a handle composed of eight gears without a load cell and a hydraulic cylinder. The serviceability and reliability of these instruments were investigated through experiments at construction sites. Furthermore, the sample pullout test with a wall specimen was conducted to estimate the usefulness of the temporary fixed bolt type of fastening methods and pullout devices. Eventually, the developed instruments will be useful on construction sites if minor requirements are met.
 
Ű¿öµå
Àι߽ÃÇè±â;ÈĸÅÀÔ ÆÄ´ÜÇü Àιߺ¼Æ®;¸ÅÀÔÀÎ¹ß ³ÊÆ®;°ÇÃà½Ã°ø;pullout tester;post-installable break-off bolt;installable pullout insert nut;building construction;
 
Çѱ¹°ÇÃà½Ã°øÇÐȸÁö / v.11, no.3, 2011³â, pp.229-237
Çѱ¹°ÇÃà½Ã°øÇÐȸ
ISSN : 1598-2033
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO201121539232522)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿