Çѱ¹°ÇÃà½Ã°øÇÐȸ / v.11, no.4, 2011³â, pp.333-344
|
°øµ¿ÁÖÅà ¹Ù´Ú¹ÌÀå ±Õ¿Â÷´Ü¸·ÀÇ ¸ÞÄ¿´ÏÁò ºÐ¼®
( An Analysis of the Mechanism of Crack Stop-bar for Floor Plastering of Apartment Buildings ) |
| ¼Û¿ë½Ä;À̵¿ÈÆ;À̼ºÈ£;±è¼±±¹; ;;;;
|
|
|
 |
|
| |
| ÃÊ ·Ï |
| ÃÖ±Ù ÁÖÅà °Ç¼³Àº ¾çÀûÀ¸·Î ÆØÃ¢ÇÏ¸é¼ ½Å°ø¹ý, ½Å¼ÒÀçÀÇ °³¹ß·Î ǰÁú¿¡ ¸¹Àº ¹ßÀüÀ» Çϰí ÀÖÀ¸³ª °øµ¿ÁÖÅà °ø»ç Áß ¹æ¹Ù´Ú ¹ÌÀåÀº Àη³°ú °ø±â´ÜÃàÀ» ÇØ°áÇϱâ À§ÇØ ±â°èÈ ½Ã°øÀ» ÇÔÀ¸·Î¼ ¹æ¹Ù´Ú ¹ÌÀåÀÇ Å©·¢¹ß»ý ¹× µé¶ä Çö»óÀ¸·Î ÀÎÇÑ ÇÏÀÚ ¹ß»ýÀ¸·Î °æÁ¦Àû, ½Ã°£Àû ³¶ºñ°¡ ¸¹´Ù. °øµ¿ÁÖÅà ¹Ù´Ú¹ÌÀåÀÇ ±Õ¿Àº Àç·áÀûÀÎ Ãø¸é¿¡¼ º¼ ¶§ »ç¿ëÀç·áÀÇ ±¸¼º°ú ½Ã°øÁ¤µµ, ¾ç»ý, º¸¾ç¹æ¹ý¿¡ µû¸¥ °¢ ¿äÀÎÀÌ º¹ÇÕÀûÀ¸·Î ÀÛ¿ëÇÏ¿© ¹ß»ýµÈ´Ù. ±×·¯³ª Àç·áÀûÀÎ Ãø¸é¿¡¼ À§ ¿äÀεéÀ» Á¦¾îÇÏ¿© ±Õ¿À» ºÎºÐÀûÀ¸·Î ¾ïÁ¦ÇÒ ¼ö ÀÖÀ¸³ª ±Ùº»ÀûÀÎ ±Õ¿¹æÁö´Â ºÒ°¡´ÉÇÏ´Ù. ±Õ¿ÀÇ ¹ß»ýÀ» ¾ïÁ¦Çϱâ À§Çؼ´Â ¹Ù´Ú¹ÌÀå ±Õ¿ÀÇ ¹ß»ý¿øÀΰú ±Õ¿ Àú°¨±â¼ú¿¡ ´ëÇÑ ³í¸®ÀûÀÎ ºÐ¼®ÀÌ ÇÊ¿äÇÏ´Ù. µû¶ó¼ º» ¿¬±¸¿¡¼´Â ¹Ù´Ú¹ÌÀå ±Õ¿ÀÇ ¿øÀΰú ±Ùº»ÀûÀÎ ¾ïÁ¦¸¦ À§ÇÑ ±Õ¿Â÷´Ü¸·ÀÇ ¸ÞÄ¿´ÏÁòÀ» ºÐ¼®ÇϰíÀÚ ÇÑ´Ù. |
|
| The recent expansion in the number of housing construction projects has been accompanied by substantial improvements in construction quality, which can be attributed to the development of new construction technologies and materials. In apartment complex construction projects, numerous mechanization technologies have been adopted as part of the floor plastering process to counter increasing difficulties in securing labor and the pressing need to reduce lead time, but these have also triggered setbacks such as additional costs or loss of time to fix cracks in or loosening of floor. Cracks developing in the floor of an apartment housing unit, in terms of materials in use, are the products of a complex combination of material makeup, construction workmanship, concrete curing and the protection method. Controlling such elements from the perspective of materials in use may ensure partial success in reducing cracks, but fall short of eliminating them completely. Any attempt to prevent cracks from developing in the first place requires systematic analysis as to their potential causes and viable solutions to reduce them. On this backdrop, this paper aims to provide an analysis of potential causes of cracks found in floor plastering, and consider the mechanism of a crack stop-bar as a fundamental safeguard against them. |
| |
| Ű¿öµå |
| ¹ÌÀå°ø»ç;±Õ¿;±¸Á¶ ¸ÞÄ¿´ÏÁò;°øµ¿ÁÖÅÃ;floor plastering;crack;structural mechanism;housing construction; |
| |
|
|
 |
|
Çѱ¹°ÇÃà½Ã°øÇÐȸÁö / v.11, no.4, 2011³â, pp.333-344
Çѱ¹°ÇÃà½Ã°øÇÐȸ
ISSN : 1598-2033
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO201125153145894)
¾ð¾î : Çѱ¹¾î |
|
| ³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø |
|
|
|
|
|
|