¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹°ÇÃà½Ã°øÇÐȸ / v.12, no.1, 2012³â, pp.54-63
»ê¾÷ºÎ»ê¹°À» »ç¿ëÇÑ Àúź¼Ò ¹«±â°áÇÕÀçÀÇ Á¶°Çº° °­µµÆ¯¼º
( Strength Properties According to the Conditions of Low Carbon Inorganic Composite Using Industrial By-product )
ÀÌÀ±¼º;ÀÌ»ó¼ö;¼ÛÇÏ¿µ; ;;;
 
ÃÊ ·Ï
º» ¿¬±¸¿¡¼­´Â »ê¾÷ºÎ»ê¹°ÀÎ °í·Î½½·¡±×, ·¹µå¸Óµå, ½Ç¸®Ä« Èâ µîÀ» »ç¿ëÇÏ¿© ÄÜÅ©¸®Æ®ÀÇ È¥È­Àç°¡ ¾Æ´Ñ ½Ã¸àÆ® ´ëüÀç·Î »ç¿ëÇÏ¿© ½Ã¸àÆ® Á¦Á¶½Ã ¹èÃâµÇ´Â $CO_2$°¡½º ¹× ȯ°æºÎÇϸ¦ Àú°¨ÇϰíÀÚ ÇÏ¿´´Ù. °í·Î½½·¡±×, ·¹µå¸Óµå, ½Ç¸®Ä« Èâ µîÀ» È¥ÇÕÇÑ Àúź¼Ò ¹«±â°áÇÕÀç¿¡ ¾ËÄ®¸® ÀÚ±ØÁ¦¸¸À¸·Î °í¿ÂÀÇ ¼Ò¼º°úÁ¤¾øÀÌ »ó¿Â¿¡¼­ Á¦Á¶Çϱâ À§ÇÑ ÃÖÀû¹èÇÕÀ» µµÃâÇϰíÀÚ ÇÏ¿´´Ù. À̸¦ À§ÇØ CaO ÇÔÀ¯·® ¹× Si/Al, ¾ËÄ®¸® ÀÚ±ØÁ¦ È¥ÇÕºñÀ² ¹× ¾ç, ¾ç»ýÁ¶°Ç ¹× W/B º¯È­¿¡ µû¸¥ °æÈ­¼º»ó ¹× ¾ÐÃà°­µµ½ÃÇèÀ» ½Ç½ÃÇÏ¿´´Ù. ½ÃÇèºÐ¼® °á°ú, Àúź¼Ò ¹«±â°áÇÕÀçÀÇ ÃÖÀû¹èÇÕÀº CaO ÇÔÀ¯·® 30%, Si/Al 4, ¾ËÄ®¸® ÀÚ±ØÁ¦ È¥ÇÕºñÀ²$(NaOHg:Na_2SiO_3g)$ 50g:50g, ¾ËÄ®¸® ÀÚ±ØÁ¦ ¾ç 100g, W/B 31%ÀÎ °ÍÀ¸·Î ÆÇ´ÜµÈ´Ù. ¶ÇÇÑ ¹«±â°áÇÕÀçÀÇ ´ÜÁ¡ÀÎ ¼öÃàÀ» º¸¿ÏÇÑ´Ù¸é º¸´Ù ¿ì¼öÇÑ ¼º´ÉÀÇ Àúź¼Ò ¹«±â°áÇÕÀçÀÇ °³¹ßÀÌ °¡´ÉÇÒ °ÍÀ¸·Î ÆÇ´ÜµÈ´Ù.
The purpose of this study is to examine the potential for reducing the environmental load and $CO_2$ gas when cement is produced by using cement substitutes. These substitutes consisted of blast furnace slag, red mud and silica fume, which were industrial by-products. The most optimum mix was derived when alkali accelerator was added to low carbon inorganic composite mixed with industrial by-product at room temperature. It is determined that hardened properties and the results of compressive strength tests changed based on CaO content, Si/Al, the mixing ratio and the amount of alkali accelerator, curing conditions and W/B. The results of test analysis suggest that the optimum mix of low carbon inorganic composite is CaO content 30%, Si/Al 4, the mixed ratio of alkali accelerator $(NaOH:Na_2SiO_3)$ 50g:50g, the amount of alkali accelerator 100g and W/B 31%. In addition, if contraction is complemented, low carbon inorganic composite with superior performance could be developed.
 
Ű¿öµå
Àúź¼Ò;¹«±â°áÇÕÀç;¾ËÄ®¸® ÀÚ±ØÁ¦;ÃÖÀû¹èÇÕ;low carbon;inorganic composite;alkali accelerator;optimum mix;
 
Çѱ¹°ÇÃà½Ã°øÇÐȸÁö / v.12, no.1, 2012³â, pp.54-63
Çѱ¹°ÇÃà½Ã°øÇÐȸ
ISSN : 1598-2033
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO201208636394570)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿