Çѱ¹µµ·ÎÇÐȸ / v.9, no.3, 2007³â, pp.111-121
|
ÀúÅäÇǺΠ¾Ï°Å»óºÎ Æ÷ÀåÀÇ µµ»óÇÇÇØ ¿¹¹æÀ» À§ÇÑ ´Ü¸í¼³°è
( A design guide to minimize frost heave in unbound pavement layers over box culverts ) |
| ¼¿µ±¹; Çѱ¹µµ·Î°ø»ç µµ·Î±³Åë±â¼ú¿ø;
|
|
|
 |
|
| |
| ÃÊ ·Ï |
| Áö³ 2005³â 12¿ù È£³²Áö¿ª¿¡ ³»¸° Æø¼³°ú ¿¬ÀÌÀº ÇÑÆÄ·Î ¼ÇؾȰí¼Óµµ·Î¿Í È£³²°í¼Óµµ·Î¿¡ ¸¹Àº ÇÇÇØ°¡ º¸°íµÇ¾ú´Ù. ƯÈ÷ 2.0m ÀÌÇÏÀÇ ÀúÅäÇÇ°í¸¦ °®´Â Åë·Î ¾Ï°Å »óºÎÀÇ Æ÷Àå¿¡ ÃÖ´ë 6.0cm ³ôÀÌÀÇ ³ë¸é À¶±â¿Í Ⱦ¹æÇâ ±Õ¿ÀÌ ¹ß»ýÇÏ¿´´Ù. ÀÌ´Â Æ÷ÀåÀÇ ¼ö¸í´ÜÃà ¹× °ø¿ë¼º ÀúÇÏ, ±³Åë»ç°í ¹ß»ý µî¿¡ ¿µÇâÀ» ¹ÌÄ¡±â ¶§¹®¿¡ ½Ã±ÞÇÑ ´ëÃ¥¸¶·ÃÀÌ ¿ä±¸µÇ¾ú´Ù. ÇöÀå Á¶»ç °á°ú ´Ü±â°£¿¡ Áõ°¡ÇÑ Ä§Åõ¼ö°¡ ³ë»ó°ú ³ëü¿¡ ÇÔÀ¯µÈ ¼¼¸³ºÐÀÇ ¿µÇâÀ¸·Î Æ÷Àå ³»ºÎÀÇ ¹è¼ö°¡ Áö¿¬µÇ°í Àú¿Â¿¡¼ ¹ß»ýÇÑ µ¿»óÀÌ Æ÷Àå ÆÄ¼ÕÀÇ ÀÏÂ÷ÀûÀÎ ¿øÀÎÀ¸·Î ÁöÀûµÇ¾ú´Ù. ÃÖ±Ù Çѱ¹µµ·Î°ø»ç´Â µµ·Î±³Åë±â¼ú¿ø°ú °øµ¿¿¬±¸¸¦ ÅëÇØ¼ ½Å¼³µÇ´Â ¾Ï°Å»óºÎ Æ÷Àå¿¡ ´ëÇÑ »õ·Î¿î ¼³°è¾ÈÀ» Á¦½ÃÇÏ¿´´Ù. º» ¼³°è¾ÈÀº ¾Ï°Å »ó´ÜºÎ¿¡ ¸Í¾Ï°Å¸¦ ¼³Ä¡ÇÏ¿© ħÅõ¼öÀÇ ¿øÈ°ÇÑ ¹è¼ö¸¦ À¯µµÇÏ°í °£±Ø¼ö¾ÐÀÇ Àú°¨À» ÅëÇØ Æ÷ÀåÇϺÎÀÇ µ¿»óÀ» ¿¹¹æÇϰíÀÚ ÇÑ´Ù. º» ³í¹®¿¡¼´Â À§ÀÇ ¼³°è¹ý °³¹ßÀ» À§Çؼ ¼öÇàÇÑ ½ÇÇè°ú ¼öÄ¡ÇØ¼®°á°ú¸¦ ´Ù·ç°í ÀÖ´Ù. ÇöÀå¿¡¼ äÃëÇÑ Áö¹Ý½Ã·á¿¡ ´ëÇÑ Á¡ÅäÇÔÀ¯·® ºÐ¼®À» ½Ç½ÃÇϰí 2Â÷¿ø À¯ÇÑ¿ä¼ÒÇØ¼®À» ½Ç½ÃÇÏ¿© °ñÀç ÀÔ°æ¿¡ µû¸¥ ħÅõ·ùÀÇ ¹è¼öƯ¼ºÀ» Á¶»çÇÏ¿´´Ù. ÀúÅäÇǰí(2.0m ÀÌÇÏ) ¾Ï°Å »óºÎ Æ÷Àå¿¡ Àû¿ëµÉ ¸Í¾Ï°ÅÀÇ ±Ô°ÝÀº ħÅõ·ù ÇØ¼®°á°ú¿Í ÇöÀå ½Ã°ø¼ºÀ» °í·ÁÇÏ¿© Æø°ú ³ôÀ̸¦ °¢°¢ 400mm, 800mm·Î °áÁ¤ÇÏ¿´´Ù. |
|
| During the whole month of December in 2005, Korea experienced both heavy snowfall and freezing temperature in southeast regions, which had caused frost related damages to many pavements laid on top of box culverts. In-situ observation revealed that the formation of ice lenses in subgrade and subsequent unbound layers led to upward heaving and transverse cracks in concrete and asphalt pavements. This has affected the long-term performance of pavements, as well as has threatened drivers' safety for a while. Recently, Korea Expressway Corporation has proposed a design guide to better protect newly constructed unbound pavement layers over culverts from frost heave. A trench drainage system has been selected to effectively draw off water and to alleviate pore-water pressure in soils during the coldest season. This paper presents experimental and analytical backgrounds behind this new design guide. Soil specimens retrieved from the sites are tested to quantify clay content and to estimate the permeability of subgrade. A 2-D ground seepage analysis has been conducted to better understand the changes in pore water pressures as a function of grain size. Finally, an optimum size of trench drainage is determined based on numerical analysis and workability in the field. |
| |
| Ű¿öµå |
| µ¿»ó;Åë·Î¾Ï°Å;Æ÷Àå;¹è¼ö;¸Í¾Ï°Å;frost;box culvert;pavement;trench drainage; |
| |
|
|
 |
|
Çѱ¹µµ·ÎÇÐȸ³í¹®Áý / v.9, no.3, 2007³â, pp.111-121
Çѱ¹µµ·ÎÇÐȸ
ISSN : 1738-7159
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200735836675735)
¾ð¾î : Çѱ¹¾î |
|
| ³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø |
|
|
|
|
|
|