¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹µµ·ÎÇÐȸ / v.8, no.1, 2006³â, pp.33-43
ÄÜÅ©¸®Æ®Æ÷Àå È®ÀåºÎ ŸÀ̹٠¼³Ä¡¹æ¹ýÀÇ °³¹ß
( Development of Tie-Bar Installation Method for Concrete Pavement Widening )
ȲÀαÔ;¾ç¼ºÃ¶;Á¤ÁøÈÆ;À¯Å¼®; R&H ±¸Á¶±â¼ú»ç»ç¹«¼Ò;È«ÀÍ´ëÇб³ °ÇÃà°øÇаú;ÀÎÇÏ´ëÇб³ ȯ°æÅä¸ñ°øÇкΠÅä¸ñ°øÇÐ;µµ·Î±³Åë±â¼ú¿ø Æ÷À忬±¸±×·ì;
 
ÃÊ ·Ï
½Å¼³Æ÷Àå¿¡ ½Ã°øµÇ´Â ŸÀ̹ÙÀÇ °æ¿ì¿¡´Â ÄÜÅ©¸®Æ® Ÿ¼³½Ã ŸÀٰ̹¡ ½½·¡ºê ¾È¿¡ ¹¯È÷±â ¶§¹®¿¡ ŸÀ̹ÙÀÇ Á¤Âø°­µµ°¡ ¹®Á¦µÇÁö ¾ÊÀ¸³ª, È®Àå½Ã¿¡´Â ±âÁ¸ Æ÷ÀåÀ» õ°øÇÑ ÈÄ ÃæÀüÀ縦 ÁÖÀÔÇÏ¿© ¼³Ä¡Çϱ⠶§¹®¿¡ ŸÀٰ̹¡ ÃæºÐÇÑ Á¤Âø°­µµ¸¦ È®º¸ ÇÒ ¼ö ÀÖµµ·Ï ¼³°èÇØ¾ß ÇÑ´Ù. ¸¸ÀÏ »ðÀÔµÈ Å¸Àٰ̹¡ ÃæºÐÇÑ Á¤Âø°­µµ¸¦ È®º¸ÇÏÁö ¸øÇÑ´Ù¸é, ½½·¡ºê °£¿¡ ÇÏÁß Àü´Þ¿¡ ¹®Á¦°¡ »ý±æ »Ó¸¸ ¾Æ´Ï¶ó ÁÙ´« °£°ÝÀÌ °úµµÇÏ°Ô ¹ú¾îÁ®¼­ »ç¿ë¼º ¹× ³»±¸¼º¿¡µµ ³ª»Û ¿µÇâÀ» ÁÖ°Ô µÈ´Ù. º» ¿¬±¸¿¡¼­´Â ÇöÀç ÇöÀå¿¡¼­ ¼³Ä¡ÇÏ´Â ½Ã°ø¹æ¹ý¿¡ ÀÇÇØ ŸÀ̹ÙÀÇ Á¤Âø°­µµ¸¦ È®ÀÎÇϰí ÀÌ¿¡ ´ëÇÑ ´ë¾ÈÀ» Á¦½Ã ÇϰíÀÚ ÇÑ´Ù. ½ÇÇè°á°ú ÇöÀå ½Ã°ø¹æ¹ýÀ¸·Î ¼³Ä¡µÈ ŸÀ̹ÙÀÇ Á¤Âø°­µµ´Â ¼Ò¿ä Á¤Âø°­µµÀÇ 42.7%¿¡ ºÒ°úÇÏ¿´´Ù. ù ¹øÂ° ´ë¾ÈÀ¸·Î¼­ ÁÖÀԱ⸦ ÀÌ¿ëÇÏ¿© ÃæÀüÀ縦 ÁÖÀÔÇÏ°í ¸¶°³¸¦ »ç¿ëÇÏ¿© ÃæÀüÀç°¡ Èê·¯ ³ª¿ÀÁö ¸øÇÏ°Ô ¸·´Â ¹æ¹ýÀÇ °æ¿ì¿¡´Â ¼Ò¿ä Á¤Âø°­µµ¸¦ ÃæºÐÈ÷ ¸¸Á· ÇÏ¿´À¸³ª, ÇöÀå¿¡¼­ÀÇ Ç°Áú°ü¸®°¡ ½±Áö ¾ÊÀ» °ÍÀ¸·Î ÆÇ´ÜµÈ´Ù. µÎ ¹øÂ° ´ë¾ÈÀ¸·Î Á¦½ÃµÈ SL ¾ÞÄ¿º¼Æ®¸¦ ÀÌ¿ëÇÏ¿© ŸÀ̹ٸ¦ ¼³Ä¡ÇÏ´Â ¹æ¹ýÀº ÃæºÐÇÑ Á¤Âø°­µµ¸¦ È®º¸ ÇÒ ¼ö ÀÖÀ¸¸ç ǰÁú°ü¸® ¹× ½Ã°ø¼ºÀÌ ¿ëÀÌ ÇÑ °ÍÀ¸·Î ÆÇ´ÜµÈ´Ù.
Pull-out strength of tie-bin used in pavement construction is not an issue because those are embedded in newly placed concrete slabs. However, sufficient pull-out strength should be secured in widening constructions because, in case, the tie-bars are inserted into drilled holes of the existing slabs with liquid filler. Insufficient pull-out strength will result in lowered load transfer efficiency between adjacent slabs in addition to poor serviceability and durability due to joint widening. The pull-out strength of the tie-bars installed by current method is evaluated and improved methods are proposed. The field pull-out strength obtained by the current method was only 42.7% of required strength. Its first counterproposal is using to insert the liquid filler into drilled holes and stoppers to prevent it from flowing out of the holes. However, this method was not judged to secure desired level of quality control. The second counterproposal which substitutes the existing type of the tie-bars by SL anchor bolts was judged to secure sufficient pull out-strength in addition to the quality control and constructibility.
 
Ű¿öµå
ÄÜÅ©¸®Æ® Æ÷Àå;È®Àå;ŸÀ̹Ù;Á¤Âø°­Á¶;¾ÞÄ¿º¼Æ®;concrete pavement;widening;tie-bar;pull-out strength;anchor bolt;
 
Çѱ¹µµ·ÎÇÐȸ³í¹®Áý / v.8, no.1, 2006³â, pp.33-43
Çѱ¹µµ·ÎÇÐȸ
ISSN : 1738-7159
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200617033452492)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿