¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹µµ·ÎÇÐȸ / v.9, no.2, 2007³â, pp.101-114
½Ã°ø¹æ¹ý¿¡ µû¸¥ ´ÙÀ£¹Ù ½Ã°ø»óÅ ºÐ¼®
( Analysis of Dowel Bar Placement Accuracy with Construction Methods )
ÀÌÀçÈÆ;±èÇü¹è;±Ç¼ø¹Î;±Ç¿À¼±; Çѱ¹µµ·Î°ø»ç µµ·Î±³Åë±â¼ú¿ø;Çѱ¹µµ·Î°ø»ç µµ·Î±³Åë±â¼ú¿ø;Çѱ¹µµ·Î°ø»ç µµ·Î±³Åë±â¼ú¿ø;Çѱ¹µµ·Î°ø»ç µµ·Î±³Åë±â¼ú¿ø;
 
ÃÊ ·Ï
ÁÙ´« ÄÜÅ©¸®Æ® Æ÷Àå¿¡¼­ ´ÙÀ£¹Ù´Â ÇÏÁßÀ» Àü´ÞÇØÁÖ´Â ¿ªÇÒ°ú ´ÜÂ÷¸¦ °¨¼Ò½ÃÄÑÁÜÀ¸·Î½á ±Ã±ØÀûÀ¸·Î Æ÷ÀåÀÇ °ø¿ë¼ºÀ» ³ô¿©ÁÖ´Â ¿ªÇÒÀ» ¼öÇàÇÑ´Ù. ±×·¯³ª ´Ù¿¤¹ÙÀÇ ½Ã°ø»óŰ¡ ºÒ·®ÇÒ °æ¿ì¿¡´Â ¿ÀÈ÷·Á ÁÙ´«Àá±è µîÀ» À¯¹ßÇÏ¿© ½ºÆú¸µÀ̳ª ±Õ¿­À» ÃÊ·¡ÇÏ¿© °ø¿ë¼ºÀ» ¶³¾î¶ß¸± ¼ö ÀÖ´Ù. ´ÙÀ£¹ÙÀÇ ½Ã°ø¹æ¹ýÀº ´ÙÀ£¹Ù ¾î¼Àºí¸® ½Ã°ø¹æ¹ý°ú ´ÙÀ£¹ÙÀÚµ¿»ðÀԱ⸦ ÀÌ¿ëÇÑ ½Ã°ø¹æ¹ýÀÌ Àִµ¥ ±¹³»¿¡¼­´Â ¾î¼Àºí¸®¸¦ ÀÌ¿ëÇÑ ½Ã°ø¹æ¹ý¸¸ÀÌ »ç¿ëµÇ°í ÀÖ´Ù. º» ¿¬±¸¿¡¼­´Â ºñÆÄ±« Á¶»çÀåºñÀÎ MIT-SCAN2¸¦ ÀÌ¿ëÇÏ¿© Çѱ¹µµ·Î°ø»ç ½ÃÇèµµ·Î¿¡ ½Ã°øµÈ ´ÙÀ£¹ÙÀÚµ¿»ðÀÔ ½Ã°ø±¸°£°ú ´ÙÀ£¹Ù ¾î¼Àºí¸® ½Ã°ø±¸°£¿¡ ´ëÇÑ ´ÙÀ£¹Ù ½Ã°ø»óÅ ¹× Joint Score¿Í Running Ave. Joint Score¸¦ »êÃâÇÏ¿© ºñ±³ ºÐ¼®ÇØ º¸¾Ò´Ù. ±× °á°ú, ´ÙÀ£¹ÙÀÚµ¿»ðÀÔ ½Ã°ø¹æ¹ýÀÌ ´ÙÀ£¹Ù ¾î¼Àºí¸® ½Ã°ø¹æ¹ý¿¡ ºñÇØ ±íÀ̺¯È­, ¼öÆò/¼öÁ÷¾ù°¥¸²¿¡¼­ ¸Å¿ì ¿ì¼öÇÑ ½Ã°ø»óŸ¦ º¸ÀÌ´Â °ÍÀ¸·Î ³ªÅ¸³µÀ¸¸ç ÁÙ´«Àá±èÀÇ À§Çè ¶ÇÇÑ ´ÙÀ£¹Ù ¾î¼Àºí¸® ½Ã°ø¹æ¹ý¿¡ ºñÇØ ¸Å¿ì ³·´Ù´Â Á¡À» ¹ß°ßÇß´Ù. ¶ÇÇÑ ±¹³» ´ÙÀ£¹Ù ¾î¼Àºí¸® ½Ã°ø¹æ¹ýÀÇ ¹®Á¦Á¡À» ´ÙÀ£¹Ù ¾î¼Àºí¸®ÀÇ »ý»ê, º¸°ü, ½Ã°ø Ãø¸é¿¡¼­ ºÐ¼®ÇÏ¿´´Ù. ¹®Á¦Á¡ ºÐ¼®À» Åä´ë·Î ´ÙÀ£¹ÙÀÇ Ã¼¾îÇüÅÂ, °íÁ¤¹æ¹ýÀ» °³¼±ÇÏ¿© ½ÃÇè½Ã°øÀ» ¼öÇàÇÑ °á°ú, ¸ðµç ½Ã°ø»óÅ Ç׸ñÀÌ °³¼±µÇ¾úÀ½À» ¾Ë ¼ö ÀÖ¾úÀ¸¸ç, ƯÈ÷ ¼öÆò/¼öÁ÷¾ù°¥¸²ÀÌ Å©°Ô °³¼±µÇ¾î ÁÙ´«Àá±è¿¡ ´ëÇÑ À§Ç輺ÀÌ ÁÙ¾îµêÀ» ¾Ë ¼ö ÀÖ¾ú´Ù.
Dowel bars in the jointed concrete pavement are used to both provide load transfer across pavements joints and prevent the joint faulting leading to longer service life. On the contrary, the misplacement of dowel bar can provide negative results including the joint freezing(locking) that may cause the joint spatting and unexpected mid-slab cracking. The dowel bar can be placed using the assembly or dowel bar inserter (DBI) during the concrete pavement construction. In the domestic practice of the concrete pavement construction, the dowel bar is placed using the assembly method. This study primarily focuses on the comparison of these two dowel placement methods using the field data from the KHC test road in which both dowel placement methods have been applied to a certain length of the concrete pavement. The field data regarding the alignment of the dowel bars placed by both methods was collected using MIT-SCAN2, a nondestructive measuring equipment, and processed to compute Joint Score and Running Ave. Joint Score which are used as indicators of the dowel bar performance. The comparison of the methods for the dowel bar placement using these indicators shows that the DBI method provided much better alignment of the dowel bars reducing the risk of joint freezing than the assembly method. In order to improve the quality of the dowel bar placement using the assembly method, the current weak points of the assembly method including the fabrication, storage, and installation of dowel bar assembly were investigated and the solution was suggested. The improved dowel bar sets based on the suggested solution have been applied to an actual practice of the concrete pavement construction. The field data shows that the improved assembly method suggested in this study can highly reduce the risk of joint freezing.
 
Ű¿öµå
ÁÙ´« ÄÜÅ©¸®Æ® Æ÷Àå;´ÙÀ£¹Ù;¾î¼Àºí¸®;´ÙÀ£¹ÙÀÚµ¿»ðÀÔ±â;Á¶ÀÎÆ® ½ºÄÚ¾î;jointed plain concrete pavement;dowel bar;assembly;dowel bar inserter;MIT-SCAN2;joint score;
 
Çѱ¹µµ·ÎÇÐȸ³í¹®Áý / v.9, no.2, 2007³â, pp.101-114
Çѱ¹µµ·ÎÇÐȸ
ISSN : 1738-7159
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200722941482002)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿