¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹µµ·ÎÇÐȸ / v.7, no.1, 2005³â, pp.73-82
½Ã¸àÆ® Á¾·ù¿¡ µû¸¥ ¶óÅØ½º°³Áú ÄÜÅ©¸®Æ®ÀÇ ¹Ì¼¼°ø±Ø ±¸Á¶ ºÐ¼®
( Analysis of Air Void Systems in Latex-Modified Concretes with Cement Types )
À±°æ±¸;Á¤¿ø°æ;±è±âÇå;±è°æÁø; °­¿ø´ëÇб³ Åä¸ñ°øÇаú;°­¿ø´ëÇб³ »ê¾÷±â¼ú¿¬±¸¼Ò;°­¿ø´ëÇб³ Åä¸ñ°øÇаú;ÃæÁÖ´ëÇб³ Åä¸ñ°øÇаú;
 
ÃÊ ·Ï
°ø±Ø±¸Á¶ ºÐ¼® ¹æ¹ýÀº ASTM C 457ÀÇ ¸®´Ï¾îÆ®·¹¹ö½º Æ÷ÀÎÆ®Ä«¿îÆ®¹ýÀÌ ÀÖÀ¸³ª, ÀÌ·¯ÇÑ ¹æ¹ýµéÀº ºÐ¼®Çϴµ¥ ½Ã°£°ú ³ë·ÂÀÌ ³Ê¹« ¸¹ÀÌ ¼Ò¿äµÇ¾î ÇöÀç¿¡´Â °ÅÀÇ »ç¿ëµÇ¾îÁöÁö ¾Ê°í ÀÖ´Ù. ±Ù·¡¿¡´Â Çö¹Ì°æ°ú µðÁöÅÐ Ä«¸Þ¶ó, ÄÄÇ»ÅÍÀÇ ÇÁ·Î±×·¥ ¹ß´Þ·Î È­»óºÐ¼®¹ýÀÌ ¸¹Àº ¿¬±¸ÀÚ¿¡ ÀÇÇØ ¿¬±¸µÇ°í ÀÖ´Ù. º» ¿¬±¸¿¡¼­´Â È­»óºÐ¼®¹ýÀ» ÅëÇÏ¿© ¶óÅØ½º°³Áú ÄÜÅ©¸®Æ®ÀÇ °ø±Ø ±¸Á¶ Ư¼ºÀ» ºÐ¼®ÇϰíÀÚ ½Ã¸àÆ® Á¾·ù(º¸ÅëÆ÷Ʋ·£µå½Ã¸àÆ®, ÃʼӰæ½Ã¸àÆ®)¿Í ¶óÅØ½º È¥ÀÔÀ²(0,15%)¿¡ µû¶ó ½ÇÇèÀ» ¼öÇàÇÏ¿´´Ù. ½ÇÇè°á°ú, ¶óÅØ½º´Â °æÈ­ ÈÄ ÄÜÅ©¸®Æ®¿¡¼­ AEÁ¦ÀÇ °ø±â¿¬ÇàÈ¿°úº¸´Ù ´õ ¿ì¼öÇÑ ¿¬Çà°ø±â ·®À» °®´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù. ¶ÇÇÑ, È­»óºÐ¼®¹ýÀ» ÀÌ¿ëÇÒ °æ¿ì °æÈ­ ÈÄ ÄÜÅ©¸®Æ® ³»ºÎ °ø±Ø ±¸Á¶¿¡ ´ëÇÑ ´Ù¾çÇÑ Á¤º¸¸¦ ºÐ¼®ÇÒ ¼ö ÀÖÀ» °ÍÀ¸·Î ÆÇ´ÜµÇ¾ú´Ù.
Linear traverse method and point count method described at ASTM have been widely used to estimate the air void system in hardened concrete. These methods, however, are rarely used at present, because they require many efforts and time consuming works. Also these results depend on each person's decision, and are not repeatable. Thus, new image analysis method using microscope and computer processes has been approached for analyzing air void system in hardened concrete. The purpose of this study was to analysis the air void systems in latex-modified concretes using a reasonable and objective image analysis method with main experimental variables such as cement types(ordinary portland cement, rapid setting cement) and latex contents(0%,15%). In the results of this study, the use of polymer latex showed that it could be attributed to its air void systems, due to the fact that the latex emulsion acts as an air-entraining agent, which thus generally guarantees an adequate air-void system.
 
Ű¿öµå
¶óÅØ½º;È­»óºÐ¼®±â¹ý;°ø±Ø ±¸Á¶;latex;LMC;VES-LMC;image analysis technique;air void system;
 
Çѱ¹µµ·ÎÇÐȸ³í¹®Áý / v.7, no.1, 2005³â, pp.73-82
Çѱ¹µµ·ÎÇÐȸ
ISSN : 1738-7159
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200515637508961)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿