Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ / v.7, no.3, 1998³â, pp.268-274
¿­¸ñÁö °æÀ¯¼¾¼­¿¡ ÀÇÇÑ ¸á·Ð °æÀ¯¾çÀÇ ÃøÁ¤
( Measurement of Mass Flow of Water in the Stem of Musk Melon by Sap Flow Gauge )
°­°î¸í;¾ç¿ø¸ð; ÀϺ» ½ÃÁî¿ÀÄ«´ëÇÐ;¼øÃµ´ëÇб³;
 
ÃÊ ·Ï
¿­¼öÁö °æ·ù¼¾¼­¿¡ ÀÇÇÑ ¸á·ÐÀÇ Èí¼ö·® ÃøÁ¤¿ÀÂ÷´Â ÃÖÀú 0.3%¿¡¼­ ÃÖ´ë 31.8% ¹üÀ§ ³»¿¡ ÀÖ¾úÀ¸¸ç, Àϻ緮 20MJ.m$^{-2}$ .d$^{-1}$¿¡¼­´Â ¿ÀÂ÷°¡ Àû¾úÀ¸³ª Àϻ緮ÀÌ À̺¸´Ù ¸¹¾ÆÁö¸é ¸¹¾ÆÁú¼ö·Ï ¼¾¼­ÃøÁ¤ °æ·ù·®ÀÌ ½ÇÃø¾ç¾× ¼Òºñ·®º¸´Ù Àû¾îÁö´Â °æÇâÀ̾ú°í Àϻ緮ÀÌ Àû¾îÁú¼ö·Ï ¼¾¼­ÃøÁ¤ °æ·ù·®ÀÌ ½ÇÃø¾ç¾× ¼Òºñ·®º¸´Ù ¸¹¾ÆÁö´Â °æÇâÀ̾ú´Ù. ¼¾¼­°£ÀÇ ¿ÀÂ÷´Â ÃÖÀú 0.1%¿¡¼­ ÃÖ´ë 13.0%ÀÇ ¿ÀÂ÷À²À» º¸¿´´Ù. ¿­¼öÁö¼¾¼­ÃøÁ¤ °æ·ù·®Àº Àϻ緮À̳ª ¿Âµµ¿Í °íµµÀÇ ºÎÀÇ »ó°ü°ü°è¸¦ º¸¿´´Ù. ±×·¯¹Ç·Î À̸¦ ÀÌ¿ë º¸Á¤°è¼ö¸¦ »êÃâÇÏ¸é º¸´Ù Á¤È®ÇÑ ¸á·ÐÀÇ °æ·ù·®À» ÃøÁ¤ÇÒ ¼ö ÀÖÀ» °ÍÀ¸·Î ÆÇ´ÜµÇ¾ú´Ù.
The mass flow of water in the stem of melon measured by Sap Flow Gauge was compared with the actual flow calculated by the difference between supply and drainage nutrient water to investigate the possibility and accuracy of estimation of melon's transpiration in rockwool culture. The Sap Flow Gauge which was made with copper-constantan theromocouple and nichrome fiber by our research team, was attached to the 3rd node of melon. The outdoor temperature, room temperature, solar radiation and relative humidity were continually measured. The amount of supply and drainage nutrient water were simultaneously measured for calculation of practical consumption of nutrient water to compare with mass flow of sap. The measuring errors of Sap Flow Gauge were 0.3 to 31.8%, which were small at solar radiation of 20MJ.m$^{2}$.d$^{-1}$ . The mass flow of water was lower for the measured value by Sap Flow Gauge than the actual value at higher solar intensity, however it was higher at lower solar intensity The variation of error rate of each Sap Flow Gauge was 0.1 to 13.0%. The measuring error with Sap Flow Gauge was negatively related with solar intensity and temperature. Therefore, to measure more exactly the mass flow of sap for estimation of melon's transpiration, the compensation factor must be calculated.
 
Ű¿öµå
°ü¼ö;±¤µµ;°æ·ù·®;Áõ»ê·®;water supply;light intensity;mass flow of Sap;transpiration;Cucumis melo;
 
»ý¹°È¯°æÁ¶ÀýÇÐȸÁö / v.7, no.3, 1998³â, pp.268-274
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
ISSN : 1229-4675
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO199811922420004)