¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ / v.11, no.2, 2002³â, pp.93-100
¿Â½Ç Æ÷±×³Ã¹æ½Ã½ºÅÛÀÇ ³Ã¹æÈ¿°ú ¿¹ÃøÀ» À§ÇÑ CFD ¸ðµ¨ÀÇ °³¹ß
( Development of CFD Model for Estimation of Cooling Effect of Fog Cooling System in Greenhouse )
À¯ÀÎÈ£;±è¹®±â;±ÇÇõÁø;±è±â¼º; ¼­¿ï´ëÇб³ ³ó°øÇаú;¼­¿ï´ëÇб³ ³ó°øÇаú;¼­¿ï´ëÇб³ ³ó°øÇаú;¼­¿ï´ëÇб³ ³ó°øÇаú;
 
ÃÊ ·Ï
º» ¿¬±¸¿¡¼­´Â Æ÷±×³Ã¹æ½Ã½ºÅÛÀ» ¼öÄ¡ÀûÀ¸·Î ½Ã¹Ä·¹À̼ÇÇϱâ À§ÇÑ CFD ¸ðµ¨À» °³¹ßÇÏ¿´À¸¸ç, Æ÷±×³Ã¹æ¿Â½Ç¿¡¼­ ÃøÁ¤µÈ µ¥ÀÌÅÍ¿¡ ÀÇÇØ °³¹ßµÈ ¸ðµ¨ÀÇ À¯È¿¼ºÀ» °ËÁõÇÏ¿´´Ù. ¶ÇÇÑ ºÐ¹«¼ö¿Â, ºÐ¹«¼ö·®, ºÐ¹«Á¤Áö½Ã°£°ú ºÐ¹«ÀÔÀÚÀÇ Áõ¹ß·üÀÌ Æ÷±×³Ã¹æ½Ã½ºÅÛÀÇ ¼º´É¿¡ ¹ÌÄ¡´Â ¿µÇâÀ» ¾Ë¾Æº¸±â À§ÇØ °³¹ßµÈ ¸ðµ¨À» Àû¿ëÇÏ¿´´Ù. ½Ã¹Ä·¹ÀÌ¼Ç °á°ú¿¡ ÀÇÇϸé, °¢ ÃøÁ¡¿¡¼­ ½ÇÃøÄ¡¿Í ¿¹ÃøÄ¡ÀÇ ¿ÂµµÂ÷°¡ ¹«Â÷±¤Á¶°Ç¿¡¼­´Â $0.1~1.4^{circ}C$, Â÷±¤Á¶°Ç¿¡¼­´Â $0.2~2.3^{circ}C$¿´À¸¸ç, »ó´ë½ÀµµÂ÷´Â ¹«Â÷±¤Á¶°Ç¿¡¼­´Â 0.3~6.0%, Â÷±¤Á¶°Ç¿¡¼­´Â 0.7~10.6%¿´´Ù. ¿¹ÃøÄ¡°¡ ½ÇÃøÄ¡¿Í ºñ±³Àû Àß ÀÏÄ¡ÇÏ´Â °ÍÀ¸·Î ³ªÅ¸³ª °³¹ßµÈ ¸ðµ¨ÀÌ Æ÷±×³Ã¹æ½Ã½ºÅÛÀÇ ³Ã¹æÈ¿°ú¸¦ ¿¹ÃøÇÒ¼ö ÀÖ´Â °ÍÀ¸·Î ÆÇ´ÜµÈ´Ù. Æ÷±×³Ã¹æ½Ã½ºÅÛ ¼º´ÉÀº ºÐ¹«¼ö·®, ºÐ¹«Á¤Áö½Ã°£°ú ºÐ¹«ÀÔÀÚÀÇ Áõ¹ß·üÀÇ ¿µÇâÀ» ¸¹ÀÌ ¹ÞÁö¸¸ ºÐ¹«¼ö¿ÂÀÇ ¿µÇâÀº ¹ÞÁö ¾Ê´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù.
This study was carried out not only to develop CFD model for numerically simulating fog cooling system but also to verify the validity of the developed model by data measured in fag cooling greenhouse. In addition the developed model was applied to investigate the effects of spraying water temperature, spraying water amount, spraying interval and evaporation percentage on the performance of the fog cooling system. According to the simulation results, the temperature differences between the measured and predicted temperatures at each measurement point were $0.1~1.4^{circ}C$ in case of no shading and $0.2~2.3^{circ}C$ in close of shading. The humidity differences were 0.3~6.0% and 0.7~10.6%, respectively in the cases of no shading and shading. Because the predicted data showed a good agreement with the measured ones, the developed model is supposed to be able to predict the cooling effect of the fog cooling system. The performance of fog cooling system was greatly influenced by spraying water amount, spraying interval and evaporation percentage, but it was not influenced by spraying water temperature.
 
Ű¿öµå
Æ÷±×³Ã¹æ½Ã½ºÅÛ;¿Â½Ç;CFD(Computational Fluid Dynamics);fog cooling system;greenhouse;
 
»ý¹°È¯°æÁ¶ÀýÇÐȸÁö / v.11, no.2, 2002³â, pp.93-100
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
ISSN : 1229-4675
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200211921033427)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿