¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ / v.12, no.3, 2003³â, pp.127-131
¿ùµ¿¿ë ¾çºÀ»çÀÇ È¯±âÆÒ ÀÛµ¿¹æ½Ä¿¡ µû¸¥ ¿Â ${cdot}$ ½Àµµ Á¶ÀýÈ¿°ú
( Control Effect of Temperature and Humidity by Ventilation Fan Operation Methods in Wintering Honey Bee House )
ÀÌÁ¾¿ø;ÀÌÇö¿ì;À̼®°Ç;±è¶õ¼÷;ÃÖ±¤¼ö; °æºÏ´ëÇб³ ³ó¾÷Åä¸ñ°øÇаú;°æºÏ´ëÇб³ ³ó¾÷Åä¸ñ°øÇаú;°æºÏ´ëÇб³ ³ó¾÷Åä¸ñ°øÇаú;½É¾ç³ó¾÷´ëÇÐ;°æºÏ´ëÇб³ µ¿¹°°øÇаú;
 
ÃÊ ·Ï
º» ¿¬±¸¿¡¼­´Â ¾çºÀ»ç ³»ºÎȯ°æÀ» º¸´Ù È¿À²ÀûÀ¸·Î Á¶ÀýÇÒ ¼ö Àִ ȯ±âÆÒ ÀÛµ¿¹æ½ÄÀ» ±¸¸íÇϱâ À§ÇÏ¿© ½Ã¹Ä·¹À̼ÇÀ» ÅëÇØ ¾ò¾îÁø ȯ±âÆÒ ÀÛµ¿¹æ½Ä¿¡ ´ëÇÑ ¿¬ ±¸°á°ú¸¦ ¾çºÀ»ç¿¡ Á÷Á¢ Àû¿ëÇÏ¿© ½ÇÇèÀ» ½Ç½ÃÇÏ¿´À¸¸ç, ¾çºÀ»ç ³»ºÎÀÇ ¿Âµµ ¹× ½Àµµº¯È­¿¡ ´ëÇÑ ½ÃÀ²·¹À̼ǰú ½ÇÇè°á°ú¸¦ ºñ±³ ${cdot}$ ºÐ¼®ÇÏ¿© ¾çºÀ»ç ¼³°è½Ã ¾çºÀ»ç ¿­È¯°æ ÇØ¼® ÇÁ·Î±×·¥ÀÇ Àû¿ë¼ºÀ» °ËÅäÇϰí, ½ÇÇè°á°ú¸¦ ÀÌ¿ëÇÏ¿© ȯ±âÆÒ ÀÛµ¿¹æ½Äº° ¾çºÀ»ç ³»ºÎȯ°æÀÇ Á¶Àý ¼º´ÉÀ» ºÐ¼®ÇÏ¿´´Ù. ±â °³¹ßµÈ ¾çºÀ»ç ¿­È¯°æ ÇØ¼® ÇÁ·Î±×·¥Àº ¾ÕÀ¸·Î ¾çºÀ»ç ¼³°è¿¡ ÀûÀýÇÏ°Ô ÀÌ¿ëÇÒ ¼ö ÀÖÀ» °ÍÀ¸·Î ÆÇ´ÜµÇ¾ú´Ù. ¿ÜºÎ±â¿ÂÀÌ ºñ½ÁÇÑ Á¶°Ç¿¡¼­´Â ȯ±âÆÒ ÀÛµ¿¹æ½Ä BÀÇ °æ¿ì°¡ AÀÇ °æ¿ìº¸´Ù ¾çºÀ»çÀÇ ³»ºÎ¿Âµµ°¡ ´ëü·Î ´õ ³·¾ÒÀ¸¸ç, Æò±ÕÀûÀ¸·Î ¹úÅë ³»ºÎ´Â 2.8$^{circ}C$, ¾çºÀ»ç ³»ºÎ´Â 2.1$^{circ}C$ ´õ ³·¾Ò´Ù. À̰ÍÀº Lee µî(1998b)ÀÌ Á¦½ÃÇÑ È¯±âÆÒ ÀÛµ¿¹æ½Ä¿¡ µû¶ó ¾çºÀ»ç ³»ºÎÀÇ ½Â¿Â¾ïÁ¦¸¦ ÃÖ°í 2.8$^{circ}C$±îÁö ÇÒ ¼ö ÀÖ´Ù´Â ³»¿ëÀ» µÞ¹ÞħÇÏ´Â ½ÇÇè°á°úÀÌ´Ù. ȯ±âÆÒ ÀÛµ¿¹æ½Ä A¿Í B ¸ðµÎ ²Ü¹úÀÌ ¿ùµ¿Çϱ⿡ ÀûÇÕÇÑ »ó´ë½Àµµ ¹üÀ§ (50~75%) ¿´À¸³ª, ¹æ½Ä B°¡ A º¸´Ù ¾çºÀ»ç ³»ºÎ ½ÀµµÀÇ ÃÖ°í ¹× ÃÖÀúÆíÂ÷°¡ ¾à 2%, Æò±Õ½Àµµ°¡ ¾à 5% Àû°Ô ³ªÅ¸³ª ½ÀµµÈ¯°æÁ¶Àý¿¡ ÀÖ¾î Á» ´õ ¾ÈÁ¤ÀûÀÎ °ÍÀ¸·Î ÆÇ´ÜµÇ¾ú´Ù. µû¶ó¼­ ȯ±âÆÒ ÀÛµ¿¹æ½Ä B´Â A ¿¡ ºñÇÏ¿© ¾çºÀ»ç ³»ºÎȯ°æÁ¶Àý ¼º´ÉÀÌ ´õ¿í ¿ì¼öÇϰí È¿À²ÀûÀÎ °ÍÀ¸·Î ÆÇ´ÜµÇ¾ú´Ù.
This study was conducted to establish the ventilation fan operation schedule to be able to provide satisfactory environment for colonies in thc wintering honey bee house. The simulation and practical measuring test were conducted to verify the applicability of an existing simulation program to thc calculation of inside thermal environment condition of the house, and the environment control performance was compared between the two types of fan operation schedule to find the proper schedule. It was concluded that the program could be used to design thc materials of the enclosure and the fan operation schedule and decide the number of accommodation hives. Inside temperature of bee house controlled by the fan operation schedule B was lower than the schedule A under the similar high outside temperature condition. In the presence of the high outside temperature condition, inside air temperature of bee house could be decreased by changing fan operation schedule A to schedule B. The humidity variation in bee house controlled by the tan operation of schedule B was smaller than that by schedule A. These results indicated that the schedule B was superior in the aspect of the environment control performance.
 
Ű¿öµå
ȯ±â¼º´É;½Ã¹Ä·¹À̼Ç;½ÇÇè;ventilation performance;simulation;experiment;
 
»ý¹°È¯°æÁ¶ÀýÇÐȸÁö / v.12, no.3, 2003³â, pp.127-131
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
ISSN : 1229-4675
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200315875836559)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿