¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ / v.20, no.1, 2011³â, pp.1-7
»ó¾÷¿ë Å丶Åä¿Â½Ç ³Ã¹æÀ» À§ÇÑ Àú¾ÐºÐ¹«½Ä Æ÷±×½Ã½ºÅÛÀÇ Àû¿ë
( Application of Low Pressure Fogging System for Commercial Tomato Greenhouse Cooling )
ÀÌÇö¿ì;±è¿µ½Ä; °æºÏ´ëÇб³;»ó¸í´ëÇб³;
 
ÃÊ ·Ï
Å丶Åä Àç¹è¿ë »ó¿±¿ë ¿Â½ÇÀÇ ¿©¸§Ã¶ ³Ã¹æ¿¡ ÃÖ±Ù ±¹³»¿¡¼­ °³¹ßµÈ Àú¾ÐºÐ¹«½Ä Æ÷±×³Ã¹æ½Ã½ºÅÛÀ» »ç¿ëÇϱâ À§ÇÑ ½Ã½ºÅÛ ¼³Ä¡ ¹× °ü¸®±â¼úÀ» ±Ô¸íÇϱâ À§ÇÏ¿© Àú¾Ð Æ÷±×½Ã½ºÅÛÀ» ¿Â½Ç¿¡ ¼³Ä¡ÇÏ¿© ½ÇÇèÀ» ÅëÇÏ¿© ±× Àû¿ë °¡´É¼ºÀ» ºÐ¼®ÇÏ¿´À¸¸ç °á°ú¸¦ ¿ä¾àÇÏ¸é ´ÙÀ½°ú °°´Ù. Æ÷±×¸¦ ºÐ»çÇÑ ¿Â½ÇÀÌ ºÐ»çÇÏÁö ¾ÊÀº ¿Â½Çº¸´Ù ¿Âµµ°¡ ´õ ³·Àº °ªÀ» º¸¿© Æ÷±×ºÐ»ç¿¡ ÀÇÇÑ ³Ã¹æÈ¿°ú°¡ ÀÖÀ½À» È®ÀÎÇÒ ¼ö ÀÖ¾ú´Ù. ±×·¯³ª ÀüüÀûÀ¸·Î »ó´ë½Àµµ°¡ ºñ±³Àû ³·°Ô ³ªÅ¸³ª ³Ã°¢È¿°ú¸¦ ÃæºÐÈ÷ ¾òÁö ¸øÇÑ °ÍÀ¸·Î ÆÇ´ÜµÇ¸ç, Æ÷±×³ëÁñÀÇ ¼³Ä¡°£°ÝÀ» ´õ ÁÙÀ̰ųª Æ÷±×ºÐ»ç ½Ã°£À» ´õ ´Ã¸®´Â µîÀÇ Á¶Á¤À» ÅëÇØ¼­ ÃæºÐÇÑ ³Ã¹æÈ¿°ú¸¦ ¾òÀ» ¼ö ÀÖÀ» °ÍÀ¸·Î ÆÇ´ÜµÇ¾ú´Ù. ¿Â½Ç ÀüüÀÇ ½Ã°£¿¡ µû¸¥ ¿ÂµµºÐÆ÷´Â ªÀº ½Ã°£ µ¿¾È¿¡´Â ¿ÂµµºÐÆ÷ÀÇ Å« º¯È­´Â ¾ø¾úÀ¸³ª ÇÏ·çÀÇ ±ä ½Ã°£ µ¿¾È¿¡´Â ¿ÂµµºÐÆ÷ÀÇ º¯È­°¡ ´Ù¼Ò Å©°Ô ³ªÅ¸³µ´Ù. ÀÌ´Â Æ÷±×ºÐ»ç¿¡ µû¸¥ ¿ÂµµÆíÂ÷ÀÇ ¹ß»ýÀº Å©Áö ¾ÊÀ¸³ª ÀÏ»ç, °ø±âÀ¯µ¿ µî ´Ù¸¥ ȯ°æ¿äÀε鿡 ÀÇÇØ ¹ß»ýµÈ ÆíÂ÷°¡ Å« °ÍÀ¸·Î ÆÇ´ÜµÈ´Ù. ƯÈ÷ º» ÀÚ·á¿¡´Â ³ªÅ¸³»Áö ¾Ê¾ÒÁö¸¸ ¿Â½Ç ÇϺο¡¼­ÀÇ ¼öÆò¹æÇâÀÇ ¿ÂµµÆíÂ÷´Â ´õ Å©°Ô ³ªÅ¸³ª´Â °æÇâÀÌ ÀÖ¾ú±â ¶§¹®¿¡ ¿ÂµµÆíÂ÷¸¦ ÁÙÀÏ ¼ö ÀÖ´Â Æ÷±×½Ã½ºÅÛ °ü¸®¹æ¾È¿¡ ´ëÇÑ ¿¬±¸°¡ ÇÊ¿äÇÒ °ÍÀ¸·Î ÆÇ´ÜµÇ¾ú´Ù. ¾ÕÀ¸·Î Ãß°¡ ½ÇÇèÀ» ÅëÇØ ÀÚ¿¬È¯±â Å丶ÅäÀç¹è¿Â½ÇÀÇ ³Ã¹æÀ» À§ÇÑ Àú¾ÐÆ÷±×½Ã½ºÅÛ ¼³Ä¡ ¹× °ü¸®±â¼úÀ» Á¦½ÃÇϰíÀÚ ÇÑ´Ù.
The objective of the present study is to identify the applicability of a low pressure fogging system for cooling commercial tomato greenhouse. In particular, the cooling system in this experiment utilizes low pressure spray nozzles which were developed in Korea recently. The experimental result that the temperature in fog-cooled greenhouse was lower than the non-cooled greenhouse showed the cooling effect by the low pressure fogging system. But because the relative humidity in fog-cooled greenhouse was comparatively low, the satisfactory cooling effect could be acquired by narrowing the space of fog nozzles and extending fogging time to supply more fog spray quantity. The variation of temperature distribution in fog-cooled greenhouse along timelag was insignificant during short time, but that was great during long period of day. This result showed the variation of temperature along timelag was slight by fog cooling but great by other factors like radiation, ventilation, air flow, etc. The advanced operation technology of fog system was required to reduce the variation of temperature along time lag. We plan to suggest the advanced installation and operation technology of low pressure fogging system for cooling commercial tomato greenhouse by further experiments in near future.
 
Ű¿öµå
³Ã¹æÈ¿°ú;³ëÁñ ¹èÄ¡;¿Â½Àµµ ºÐÆ÷;Àú¾Ð½Ä Æ÷±×³ëÁñ;Æ÷±×ºÐ»ç½Ã°£;cooling effect;distribution of temperature and humidity;fogging duration;low pressure fog nozzle;nozzle arrangement;
 
»ý¹°È¯°æÁ¶ÀýÇÐȸÁö / v.20, no.1, 2011³â, pp.1-7
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
ISSN : 1229-4675
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO201120661416936)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿