¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹°Ç¼³°ü¸®ÇÐȸ / v.2, no.3, 2001³â, pp.92-100
¼³°èÁ¤º¸ ÂüÁ¶¸¦ À§ÇÑ ½Ã¹æÁ¤º¸ÀÇ ÀڷᱸÁ¶È­¿¡ °üÇÑ ¿¬±¸
( A Study on the Data Organization of Specification Information for reference of Design Information )
±èÀçÇö;¼Û¿µ±Ô;±è¾ï; È«ÀÍ´ë;È«ÀÍ´ë °ÇÃàÇаú;È«ÀÍ´ë °ÇÃàÇаú;
 
ÃÊ ·Ï
°Ç¼³°ø»çÀÇ °è¾à¹®¼­¿¡´Â ¼³°èµµ¸é, °ø»ç½Ã¹æ¼­ µîÀÌ Æ÷ÇԵȴÙ. ±×·¯³ª °ø»ç½Ã¹æ¼­ÀÇ °æ¿ì ºÐ¼­ÀÇ Á߿伺¸¸Å­ Ȱ¿ëµÇÁö ¸øÇϰí ÀÖ´Ù. ±× ÀÌÀ¯´Â ½Ã¹ßÁ¤º¸°¡ ¼³°èµµ¸é°ú Àç·á¸¶°¨Ç¥µî ´Ù¸¥ °ÇÃàÁ¤º¸µé°ú °ü·ÃµÇ¾î ãÀ» ¼ö ÀÖ°Ô µÇ¾îÀÖÁö ¾Ê¾Æ Ȱ¿ëµµ°¡ ¶³¾îÁø´Ù. µû¶ó¼­ ´Ù¸¥ Á¤º¸¿Í ¿¬°üµÇ¾î Áú ¼ö ÀÖ´Â ÅëÇÕ¸ðµ¨ÀÌ ÇÊ¿äÇϰí ÀÌ·¯ÇÑ ÅëÇÕ¸ðµ¨À» ¹ÙÅÁÀ¸·ÎÇÑ DB°¡ ±¸ÃàµÇ¾î Á®¾ß ¼³°è ¹× ½Ã°ø, À¯Áö°ü¸®½Ã¿¡ ±× Ȱ¿ë¼ºÀÌ Áõ´ëµÈ´Ù. ÀÌ·¯ÇÑ ÅëÇÕ¸ðµ¨ÀÇ ±¸ÇöÀº ºÎÀ§¸¦ »ç¿ëÇÔÀ¸·Î¼­, ¼³°èµµ¸¦ ÀÛ¼ºÇÏ°í ±×¸®°í ºÎÀ§ Á¤º¸¿¡ ÀÚÀçÁ¤º¸, ¹ý±ÔÁ¤º¸, ½Ã¹æÁ¤º¸ÀÇ ¼Ó¼ºÀÌ µé¾î°¡ ÀÖ´Ù¸é °ßÀûÀ» ³¾ ¼ö ÀÖ°í ¸¹Àº Á¤º¸¸¦ ÂüÁ¶ÇÒ ¼ö ÀÖ¾î ¼³°èÀÇ ÁúÀÌ Çâ»óµÉ °ÍÀÌ´Ù. ¶ÇÇÑ À¯Áö°ü¸®½Ã¿¡µµ ¼³°èÁ¤º¸¿¡ ¹ý±Ô, ÀÚÀçÁ¤º¸, ½Ã¹æÁ¤º¸°¡ µé¾î°¡ Àֱ⠶§¹®¿¡ ¼ö¼±À¯Áö ¹× ÇÏÀÚº¸¼öµî¿¡ À¯¿ëÇÏ°Ô »ç¿ëµÈ´Ù. ¼³°è´Ü°è¿¡¼­ºÎÅÍ ¸¸µé¾îÁø ½Ã¹æÁ¤º¸ DB´Â ¼³°èÀÇ ¼öÁ¤°ú °ø»çÀÇ ¼öÁ¤¿¡ ¸Â°Ô update µÇ¾î Á®¾ß ÇÑ´Ù. ¶ÇÇÑ ½Ã°øÇöÀåÀ̳ª °¨¸®½Ã¿¡µµ Âü°í¸¦ Çϱâ À§Çؼ­´Â ½Ã¹æ¼­°¡ webÀ» ÀÌ¿ëÇÑ ¹®¼­È­°¡ µÇ¾î ¾îµð¼­µçÁö ÂüÁ¶ÇÒ ¼ö Àִ ȯ°æÀÌ µÇ¾î Á®¾ß¸¸ ÇÑ´Ù. µû¶ó¼­ º» ¿¬±¸¿¡¼­´Â ½Ã¹æÁ¤º¸ ±¸Á¶È­¸¦ À§ÇÑ ºÎÀ§ºÐ·ù ü°è±Û Á¦½ÃÇϰí, À̸¦ ¹ÙÅÁÀ¸·Î ÇÏ¿© °ÇÃà½Ã¹æÁ¤º¸¸¦ DBÈ­Çϸç, DB¸¦ »óÈ£ ÂüÁ¶ÇÒ ¼ö ÀÖ´Â ÀÎÅÍ³Ý È¯°æ¿¡¼­ÀÇ ½Ã¹æÁ¤º¸ÀÇ °Ë»ö ºû ÀÛ¼ºÀÌ °¡´ÉÇϵµ·Ï ÇÏ¿´´Ù. ÀÌ ½Ã½ºÅÛÀ» Ȱ¿ëÇÏ¿© °ø»ç½Ã¹æ¼­Ãâ ÀÛ¼º, ÂüÁ¶ÇÔÀ¸·Î½á °ø»ç½Ã¹æ¼­ÀÇ È°¿ëÀÇ Çâ»óÀÌ ±â´ëµÇ·Á À̸¦ ÅëÇØ °Ç¼³°ø»çÀÇ Å¬·¹ÀÓ ¹æÁö¿Í ¼³°è, ½Ã°ø, À¯Áö°ü¸®ÀÇ Ç°Áú Çâ»óÀÌ ±â´ëµÈ´Ù. ¶Ç ¹ßÁÖ±â°ü, ¼³°è¿ë¿ª¾÷ü, °ø»çÇöÀå µîÀÇ ½Ç¹«¿¡¼­ ´õ¿í Æí¸®ÇÏ°Ô Á¤º¸¸¦ Ȱ¿ëÇÒ ¼ö ÀÖÀ» °ÍÀ¸·Î »ç·áµÈ´Ù. ÇϰÚÁö¸¸)ÃàÀûµÈ AVO ºÐ¼®±â¹ýÀ» Àû¿ë ½Ã ¼®À¯Å½»ç¿¡¼­ À§Çè·ü Á¦°í¿¡ ±â¿©ÇÒ ¼ö ÀÖÀ» °ÍÀ¸·Î ±â´ëµÈ´Ù.Á¤¿¡ ³ªÅ¸³ª´Â ´Ù¾çÇÑ Ç¥Çöµé¿¡ ´ëÇÑ ½É¸®ÇÐ ¹× ¾ð¾îÇÐÀÇ °­·ÂÇÑ ¿¬±¸°¡ ¿ä±¸µÈ´Ù.¿¡ ±â´ë¾î ÅØ½ºÆ®, ¹®Àå, ¾îÈÖ¿µ¿ª µîÀÌ ÅõÀԵǾî Àû¿ëµÇ¾úÀ¸¸ç, ÀÌ¿¡ »óÀÀµÇ°Ô ±¸Ã¼ÀûÀÎ ¸î¸î ¹æ¾ÈµéÀÌ Á¦½ÃµÇ¾ú´Ù. ÇнÀÀÚµéÀÌ ÅØ½ºÆ®¸¦ Àаí Á߽ɳ»¿ëÀ» ã¾Æ³»¸ç, ´Ü¶ôÀ» ±¸È¹ÇÏ°í ¶ÇÇÑ Ã¼°è¸¦ ÆÄ¾ÇÇϴµ¥ À־ ¾îÈÖ¿¬½ÀÀº ¿Ü±¹¾î ±³¼ö¹ý Ãø¸é¿¡¼­µµ ¸Å¿ì °ü¿©ÀûÀÌ¸ç ½ÃÀÇÀûÀýÇÑ °úÁ¦¶ó »ý°¢µÈ´Ù. Sd 2) PL - Sn - pS: (1) PL[VPL - Sa] - Sn - pS (2) PL[VPL - pS] - Sn - pS (3) PL(VPL - Sa - pS) - Sn - pS 3) PL[VPL - pS) - Sn -Sa $cdot$ 3°¡ µ¿»ç °ü¿ë±¸: (1) PL[VPL - pS] - Sn - Sd - Sa (2) PL[VPL - pS] - Sn - Sa - pS (3) PL[VPL - Sa] - Sn - Sd - pS ÀÌ·¯ÇÑ ºÐ·ù°¡ º¸¿©ÁÖµíÀÌ, µ¶ÀϾ´Â 1°¡, 2°¡, 3°¡ÀÇ °ü¿ë±¸°¡ ÀÖÀ¸¸ç, ±¸Á¶ ¿ÜÀûÀ¸·Î µ¿ÀÏÇÑ Åë»çÀû °áÇÕ°¡¸¦ °®´Â´Ù ÇÏ´õ¶óµµ ±¸Á¶ ³»Àû ¼ººÐ±¸Á¶°¡ ´Ù¸£´Ù´Â °ÍÀ» ¾Ë ¼ö ÀÖ´Ù. ¿ì¸®´Â ÀÌ ±ÛÀÌ ¿Ü±¹¾î·Î¼­ÀÇ µ¶ÀϾ ¹è¿ì´Â À̵鿡°Ô µ¶ÀϾîÀÇ °ü¿ë±¸¸¦ º¸´Ù ¿Ã¹Ù¸£°Ô ÀÌÇØÇÒ ¼ö ÀÖ´Â ¹æ¹ý·ÐÀûÀÎ Åä´ë¸¦ Á¦°øÇÔÀº ¹°·Ð, (°ü¿ë¾î) »çÀü¿¡¼­ ¿Ü±¹ÀÎ ÇнÀÀÚ¸¦ °í·ÁÇÏ¿© °ü¿ë±¸¸¦ ¾Ë±â ½±°Ô ±â¼úÇÏ´Â µ¥ µµ¿òÀ» ÁÙ ¼ö Àֱ⸦ ¹Ù¶õ´Ù.µÇ±â ½ÃÀÛÇϸ鼭 ³²È²ÇØ ºÐÁö´Â ±¸Á¶¿ªÀüÀÇ Çö»óÀÌ ÀϾÀ¸¸ç, µ¿½Ã¿¡ ¹ßÇØ ºÐÁö´Â Àθ®Çü ºÐÁö·Î ¹ß´ÞÇÏ°Ô µÇ¾ú´Ù. µû¶ó¼­, ¿Ã¸®°í¼¼ µ¿¾È ¹ßÇØ ºÐÁö¿¡¼­
The architectural drawing, construction project specification, etc. are included in the contract of a documents. However, construction project specification, for being documentation, is not utilized to such an extent. The reason is that specification information is difficult in collecting information in relation to the architectural drawing, material finishing list and other architectural information. Therefore, an integrated model, which can be associated with other architectural information, is needed, and a DB based on this integrated model must be established in order for it to be utilized in design, construction, and management. The DB, which is established through this process, must be updated according to modification in design, and construction. Furthermore the specification must be in document on the web for reference. Consequently in this research, the structure of integrated model has been introduced, and it has made the search and preparation of the integrated model on the Internet, using the specification information DB established for the mutual reference of DB, possible. The improvements of construction project specification standards are expected by this system. Also, it will bring about Improvements upon claim prevention, and design, construction, management qualities. Furthermore, it will make the use of information more convenient in practical business such as order agency, design service and building site.
 
Ű¿öµå
¼³°èÁ¤º¸ »óÈ£ÂüÁ¶;°ø»ç½Ã¹æ¼­;ºÎÀ§º° ÀڷᱸÁ¶È­;À¥ ȯ°æ;
 
Çѱ¹°Ç¼³°ü¸®ÇÐȸ³í¹®Áý / v.2, no.3, 2001³â, pp.92-100
Çѱ¹°Ç¼³°ü¸®ÇÐȸ
ISSN : 2005-6095
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200120828329784)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿