¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹¼öÀÚ¿øÇÐȸ / v.22, no.1, 1989³â, pp.81-90
»ïÂ÷¿øÁ¤»óÁöÇϼö¸ðÇü¿¡ ÀÇÇÑ È«Àû´ëÁöÀÇ ÁöÇϼö·ùµ¿Çؼ®
( Groundwater Flow Analysis Using a Steady State Three-dimensional Model in an Upland Area )
¹è»ó±Ù; °è¸í´ëÇб³;
 
ÃÊ ·Ï
È£¼ö¿Í Á¢Çϰí ÀÖ´Â È«Àû´ëÁöÀÇ ÁöÇϼö·ùµ¿°è¸¦ ¾Ë±â À§ÇÏ¿© »ïÂ÷À¯ÇÑÂ÷ºÐ¸ðÇüÀ» °³¹ßÇÏ¿© »ïÂ÷¿øÁ¤»ó¸ðÀÇ ¹ß»ýÀ» ÇàÇÏ¿´´Ù. ´ëÇ¥ÁöÃþ¼Ó¿¡ Á¡ÅäÃþÀÌ ·»Áî»óÀ¸·Î Æ÷ÇԵǾî ÀÖ¾î ¼¼°¡Áö °æ¿ìÀÇ À̹漺À» °í·ÁÇÏ¿´´Ù. ¸ðÀÇ ¹ß»ý¿¡´Â 60$ imes$50$ imes$30=90,000ÀÇ °ÝÀÚÁ¡À» ¼³Á¤ÇÏ¿´À¸¸ç ¼ö¼ÓÆÇÁ¤Ã¼°è´Â 0.001m·Î ÇÏ¿´´Ù. ¼¼°¡Áö °æ¿ìÀÇ À̹漺¿¡ ´ëÇÏ¿©, »ïÂ÷¿øÁ¤»ó¸ðÀÇ ¹ß»ýÀ» ÇàÇÏ¿© ¾ò¾îÁø °á°ú·ÎºÎÅÍ ÇØ¼®µÈ ÁöÇϼö·ùµ¿°è¿Í ÃßÀûÀÚ ¹× ¼öÁú¿¡ ÀÇÇÑ ÇØ¼®(¹è.ºñ±Ù, 1987)ÀÇ °á°ú¸¦ ºñ±³ÇÏ¿´´Ù. »ïÂ÷¿øÇؼ®¿¡¼­ ¾ò¾îÁø ³× °³ÀÇ ´ëÇ¥ÀûÀÎ ¿¬Á÷2Â÷¿ø µî Æ÷ÅÙ¼£´Ü¸éÀ¸·ÎºÎÅÍ ¿¬±¸Áö¿ªÀÇ ÁöÇϼö·ùµ¿°è¸¦ ÃßÁ¤ÇÏ¿´À¸¸ç ±× °á°ú´Â À¯¿ª»êÃâÀ²°ú ÁöÇϼöÀÇ ÇÔ·®-À¯Ãâ·® ºÐÆ÷·ÎºÎÅÍ ÃßÁ¤µÇ´Â °á°ú¿Í ´Ù¸§ÀÌ ¾ø¾ú´Ù.
A numerical simulation technique of three-dimensional finite difference model is developed to study the groundwater flow system in Dejima, an upland area which faces Kasumigaura Lake. For general perspectives of the groundwater flow system, a steady state three-dimensinal model is simulated. For the sedimentary mud formations which are found in the representative formation, three situations where the horizontal permeability is equal to 10 times and 100 times of the vertical one. The finite difference grid used in the simulation has 60$ imes$50$ imes$30=90,000 nodes. A converged solution with a tolerance of 0.001 meter of hydraulic head is set. Having determined the flow net by using a steady state three-dimensional model, the results for the three cases of hydraulic conductivity are compared with the results of the tracer methods (Bae and Kayane, 1987). With the aid of four representative vertical cross-sections, groundwater flow systems in the study area are assumed. The results of these are reasonally good comparable with the results of the basin yield and thd recharge-discharge distribution 8.
 
Ű¿öµå
 
Çѱ¹¼öÀÚ¿øÇÐȸÁö / v.22, no.1, 1989³â, pp.81-90
Çѱ¹¼öÀÚ¿øÇÐȸ
ISSN : 1738-9488
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO198911920092611)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿