¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹¼öÀÚ¿øÇÐȸ / v.41, no.12, 2008³â, pp.1173-1185
ºÎµî·ù ÇØ¼®À» ±â¹ÝÀ¸·Î ÇÑ ³ë¸é¹è¼ö½Ã¼³ ¼³°è
( Design of Road Surface Drainage Facilities Based on Varied Flow Analysis )
±¸ÇýÁø;±èÁø¼ö;¹ÚÇü¼·;Àü°æ¼ö; °í·Á´ëÇб³ °ø°ú´ëÇÐ °ÇÃà.»çȸȯ°æ°øÇаú BK21»ç¾÷´Ü;¼º±Õ°ü´ëÇб³ °ø°ú´ëÇÐ °Ç¼³È¯°æ½Ã½ºÅÛ°øÇаú;´ë¸²»ê¾÷(ÁÖ) Åä¸ñ¼³°èÆÀ;¼º±Õ°ü´ëÇб³ °ø°ú´ëÇÐ »çȸȯ°æ½Ã½ºÅÛ°øÇаú;
 
ÃÊ ·Ï
³ë¸é¹è¼ö½Ã¼³ÀÇ ¼³°è¹æ¹ýÀ» ÀÓ°èÁö¼Ó½Ã°£ÀÇ °í·Á ¿©ºÎ¿Í µî·ù ¹× ºÎµî·ùÀÇ ÇØ¼® ¹æ¹ý¿¡ µû¶ó 4°¡Áö·Î ±¸ºÐÇϰí, °¢ ¹æ¹ý¿¡ µû¸¥ ¼³°è°á°ú¸¦ ºñ±³¡¤°ËÅäÇÏ¿´´Ù. ÀÓ°èÁö¼Ó½Ã°£À» °í·ÁÇÏÁö ¾Ê´Â ¹æ¹ý¿¡¼­ ¼³°è°­¿ì´Â 10ºÐ Áö¼Ó½Ã°£ÀÇ °­¿ì°­µµ·Î Á¤Çϳª, ÀÓ°èÁö¼Ó½Ã°£À» °í·ÁÇÒ °æ¿ì ¼³°è°­¿ì´Â °­¿ìÀÇ Áö¼Ó½Ã°£°ú À¯ÃâÀÇ µµ´Þ½Ã°£ÀÌ À¯»çÇØÁö´Â °æ¿ì¸¦ ½Ã»êÀûÀ¸·Î ã¾Æ °áÁ¤ÇÑ´Ù. 4°¡Áö ¼³°è¹æ¹ýÀ¸·Î ¼ö¸³µÈ ¼³°è¸ðÇüÀ» ´Ù¾çÇÑ ¼ö·ÎÀÇ Á¾´Ü°æ»ç ¹× ±æ¾î±ú Ⱦ´Ü°æ»ç¸¦ °¡Áö´Â ³ë¸é¹è¼ö½Ã¼³¿¡ Àû¿ëÇϰí, ±× ¼³°è°á°ú¸¦ ºñ±³ °ËÅäÇÏ¿´´Ù. 10ºÐ Áö¼Ó½Ã°£ÀÇ °­¿ì°­µµ¸¦ ÀÌ¿ëÇÏ´Â °æ¿ì, ºÎµî·ù ÇØ¼®À» ±â¹ÝÀ¸·Î ¼³°èÇÑ À¯Ãⱸ °£°ÝÀº Á¾´Ü°æ»ç¿Í ±æ¾î±ú Ⱦ´Ü°æ»ç°¡ ÀÛÀº °æ¿ì¿¡¸¸ µî·ù ÇØ¼®º¸´Ù Å©°Ô »êÁ¤µÇ¾ú´Ù. ¹Ý¸é µµ´Þ½Ã°£À» »êÁ¤ÇÏ¿© ÀÓ°èÁö¼Ó½Ã°£À» °áÁ¤ÇÏ´Â °æ¿ì¿¡´Â º» ¿¬±¸¿¡¼­ °í·ÁµÈ ¸ðµç Á¶°Ç¿¡¼­ ºÎµî·ù ÇØ¼®À» ±â¹ÝÀ¸·Î ¼³°èÇÑ À¯Ãⱸ °£°ÝÀÌ µî·ù ÇØ¼®º¸´Ù Å©°Ô »êÁ¤µÇ¾ú´Ù. ±×·¯³ª µµ´Þ½Ã°£À» »êÁ¤ÇÏ¿© ÀÓ°èÁö¼Ó½Ã°£À» °áÁ¤ÇÏ°í ºÎµî·ù ÇØ¼®À» ±â¹ÝÀ¸·Î ¼³°èÇÑ À¯Ãⱸ °£°ÝÀº 10ºÐ Áö¼Ó½Ã°£ÀÇ °­¿ì°­µµ¸¦ Àû¿ëÇÏ°í µî·ù ÇØ¼®À» ±â¹ÝÀ¸·Î ¼³°èÇÑ °ªº¸´Ù Ç×»ó ÀÛÀº °ÍÀ¸·Î Á¶»çµÇ¾ú´Ù.
The design methods of the road surface drainage facilities were compared for the improvement of design method. We have developed four computational design models classified by the methods to determine the duration of design rainfall and to analyze the flow of a linear drainage channel. The critical duration was determined by assuming the critical duration to be 10 minutes or by finding the duration of design storm being similar to the travel time of flow by trial and error. The flow of a linear drainage channel was analyzed as the uniform flow or the varied flow. The design models were applied to the artificial road surface drainage facilities with various channel slopes and road shoulder slopes. If the rainfall intensity of the 10 minutes duration was applied, the outlet spacing obtained from the design based on the varied flow analysis was larger than the uniform flow analysis only when the channel slope and the road shoulder slope was small. On the other hands, if the duration of design rainfall was determined by calculating the travel time, the varied flow analysis brought about larger outlet spacing than the uniform analysis for all conditions. However, the model of the critical duration concept and the varied flow analysis resulted in smaller outlet spacing than the current design method employing the rainfall of 10 minutes duration and the uniform flow analysis.
 
Ű¿öµå
³ë¸é¹è¼ö;¼±Çü ¹è¼ö·Î;ºÎµî·ù;ÀÓ°èÁö¼Ó½Ã°£;À¯Ãⱸ °£°Ý;road surface drainage;linear drainage channel;varied flow;ciritical duration;outlet spacing;
 
Çѱ¹¼öÀÚ¿øÇÐȸ³í¹®Áý / v.41, no.12, 2008³â, pp.1173-1185
Çѱ¹¼öÀÚ¿øÇÐȸ
ISSN : 1226-6280
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200803544453007)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿