¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹¼öÀÚ¿øÇÐȸ / v.37, no.2, 2004³â, pp.163-172
¿ì¼öÀ¯Ãâ¼öÀÇ µµ½ÃÇÏõ À¯ÁöÀ¯·® Ȱ¿ëÀ» À§ÇÑ ÁöÇÏÀú·ù½Ã½ºÅÛ °³¹ß
( Development of the Sub-soil Storage System for Utilization Urban Instream Flow of Rainfall Runoff )
ÃÖ°è¿î;ÃÖÁ¾¿µ;±è¼®ºÀ; ÀÎõ´ëÇб³ Åä¸ñȯ°æ½Ã½ºÅÛ°øÇаú;ÀÎõ´ëÇб³ Åä¸ñȯ°æ½Ã½ºÅÛ°øÇаú;À°±º»ç°üÇб³ Åä¸ñ°øÇаú;
 
ÃÊ ·Ï
º» ¿¬±¸¿¡¼­´Â ¿ì¼öÀ¯Ãâ¼öÀÇ µµ½ÃÇÏõ À¯ÁöÀ¯·® Ȱ¿ëÀ» À§ÇÑ ÁöÇÏÀú·ù½Ã½ºÅÛÀ» °³¹ßÇÏ°í ½ÇÇèÀ» ÅëÇÏ¿© Àû¿ë¼ºÀ» °ËÅäÇÏ¿´´Ù. À̸¦ À§ÇØ 5m${ imes}$5m Å©±âÀÇ À¯Ãâ¸éÀû¿¡ Àΰø°­¿ìÀåÄ¡¿Í ÁöÇÏÀú·ù½Ã¼³À» ¼³Ä¡Çϰí, Àΰø°­¿ì ½ÇÇè°ú ½ÇÁ¦ °­¿ì ½ÇÇèÀ» ÅëÇÏ¿© À¯Ãâ¼öÀÇ ¼öÁú°³¼± È¿°ú¿Í Àú·ù È¿°ú¸¦ ºÐ¼®ÇÏ¿´´Ù. °­¿ì°­µµ¸¦ 20mm/hr, 30mm/hr, 40mm/hr, 50mm/hr·Î Á¶ÀýÇÏ¿© Àΰø°­¿ì ½ÇÇèÀ» ½Ç½ÃÇÑ °á°ú, ÁöÇÏÀú·ù½Ã½ºÅÛ¿¡ ÀÇÇÑ À¯Ãâ¼öÀÇ SS³óµµ Àú°¨Àº Æò±Õ 68%·Î ³ªÅ¸³µÀ¸¸ç, Àú·ùÀ²Àº 42.8%¡­79.9%·Î ³ªÅ¸³µ´Ù. ÃÑ 3ȸ¿¡ °ÉÄ£ ½ÇÁ¦°­¿ì ½ÇÇè¿¡¼­´Â BOD, CO $D_{Mn}$ , SS, T-N, T-PÀÇ Æò±Õ ¿©°úÀ²Àº °¢°¢ 30%, 42%, 68%, 39%, 26%·Î ³ªÅ¸³µ´Ù. º» ½ÇÇèÀ» ÅëÇÏ¿© ÁöÇÏÀú·ù½Ã½ºÅÛ¿¡ ÀÇÇÑ ¿ì¼öÀ¯Ãâ¼öÀÇ ¼öÁú°³¼±°ú À¯Ãâ·® Àú°¨ È¿°ú°¡ »ó´çÈ÷ Å« °ÍÀ¸·Î ³ªÅ¸³µÀ¸¸ç, ÁöÇÏÀú·ù½Ã¼³¿¡ Àú·ùµÈ ¿ì¼öÀ¯Ãâ¼ö´Â ÇÏõÀ¯Áö¿ë¼ö µîÀ¸·Î »ç¿ëÀÌ °¡´ÉÇÒ °ÍÀ¸·Î ÆÇ´ÜµÈ´Ù.
In this paper, the sub-soil storage system for utilizing urban instream flow of rainfall runoff was developed and examined through experiments. The artificial rainfall facility and sub-soil storage were installed in the experimental area. The effect of the water qualify improvement and the storage effect were analyzed through the several experiments. Through the experiments of rainfall intensity variation, which are the rainfall intensity of 20mm/hr, 30mm/hr, 40mm/hr, 50mm/hr was indicated SS concentration can be reduction until 68£¥. Also, the ration of the storage volume is varied from 42.8£¥¡­79.9£¥ based on the rainfall intensity. The reduction rate of the BOD, CO $D_{Mn}$, SS, T-N, T-P was 30£¥, 42£¥, 68£¥, 39£¥, 26£¥. As the result, water quality of runoff and efficient of runoff reduction by the system are much improved. The rainfall runoff with the installation of sub-soil storage could be used for instream flow..
 
Ű¿öµå
À¯¼öÀ¯Ãâ¼ö;ÇÏõÀ¯ÁöÀ¯·®;ÁöÇÏÀú·ù½Ã¼³;Àΰø°­¿ìÀåÄ¡;Rainfall Runoff;Instream Flow;Sub-soil Storage;Artificial Rainfall Facility;
 
Çѱ¹¼öÀÚ¿øÇÐȸ³í¹®Áý / v.37, no.2, 2004³â, pp.163-172
Çѱ¹¼öÀÚ¿øÇÐȸ
ISSN : 1226-6280
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200411922294663)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿