¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹¼öÀÚ¿øÇÐȸ / v.37, no.4, 2004³â, pp.273-281
´Ù¸ñÀû´ï ¿ë·® ÀçÇÒ´ç¿¡ ´ëÇÑ ¿¬±¸(I)- Ä¡¼ö¿ë·® ºÐ¼®
( A Study for Storage Reallocation of Multipurpose Reservoir(I) - Flood Control Storage Analysis )
ÀÌÀçÀÀ;±Ç¿ëÀÍ;À±¿ë³²;¾ÈÅÂÁø; ¾ÆÁÖ´ëÇб³ ȯ°æ°Ç¼³±³Åë°øÇкÎ;¾ÆÁÖ´ëÇб³ °Ç¼³±³Åë´ëÇÐ;°í·Á´ëÇб³ Åä¸ñȯ°æ°øÇÐ;ÇѰæ´ëÇб³ Åä¸ñ°øÇаú;
 
ÃÊ ·Ï
ÀϹÝÀûÀ¸·Î Àú¼öÁö´Â °Ç¼³µÇ±â ÀÌÀü¿¡ ¼³Á¤µÈ ÀÌ¿ë°èȹ¿¡ µû¶ó ¿ë·®ÀÌ ÇÒ´çµÇ°í, ¹æ·ù·®ÀÇ Á¶Àý·Î ¿î¿µÁ¤Ã¥ÀÌ È®¸³µÈ´Ù. ÀÌ·¸°Ô ¼ö¸³µÈ Àú¼öÁö ÇÒ´ç°èȹÀº ´ïÀÇ Áõ°í ¶Ç´Â ¿ëµµº¯°æ°ú °°Àº Ưº°ÇÑ »çÇ×ÀÌ ¹ß»ýÇϱâ Àü±îÁö´Â º¯È­µÇÁö ¾Ê´Â´Ù. ÇÏÁö¸¸ ½Ã°£ÀÌ °æ°úÇÔ¿¡ µû°¡ °ø°øÀÇ Çʿ伺°ú ¸ñÀû¿¡ º¯È­°¡ ¹ß»ýÇÒ ¼ö ÀÖÀ¸¹Ç·Î À̸¦ ¹Ý¿µÇϱâ À§ÇÑ ÇϳªÀÇ ´ë¾ÈÀ¸·Î¼­ ´Ù¸ñÀû´ïÀÇ ¿ë·® ÀçÇÒ´ç¿¡ ´ëÇÑ ¿¬±¸¸¦ ¼öÇàÇÏ¿´´Ù. º» ¿¬±¸¿¡¼­ ±Ý°­À¯¿ªÀÇ ´ëû´Ù¸ñÀû´ïÀ» ´ë»óÀ¸·Î ¿©·¯ °¡Áö Àú¼ö¿ë·® ÀçÇÒ´ç ´ë¾È¿¡ ´ëÇÏ¿© È«¼öÁ¶Àý¿ë·®¿¡ ´ëÇÑ Æò°¡¸¦ ½Ç½ÃÇÑ °á°ú, ´ëû´ïÀÇ »ó½Ã¸¸¼öÀ§¸¦ Áõ°¡½ÃŰ´õ¶óµµ µ¿ÀÏÇÑ È«¼ö»ç»ó¿¡ ´ëÇÏ¿© ´ëû´ï ´Üµ¶¿î¿µÀÇ °æ¿ì º¸´Ù È«¼ö Á¦¾î´É·ÂÀÌ °¨¼ÒÇÏÁö ¾Ê´Â´Ù´Â °ÍÀ» È®ÀÎÇÒ ¼ö ÀÖ¾ú´Ù.
Generally, reservoir storage is allocated according to planned purposes established before construction and operating policies are established through release control. The established reservoir allocation is hardly changed unless the special cases such as raising dam or changed purposes occur It Is, however, likely that public needs and objectives can be changed as time go on, the study for multipurpose reservoir storage reallocation is performed as an alternative to reflect these. In this study, flood control analysis is performed for several alternatives of reallocation for the Daechung multi-purpose reservoir in Geum river. As a result, it is confirmed that flood control capability is not decreased compared to single operation of Daechung reservoir for the same flood condition even if conservation level of Daechung multi-purpose reservoir is increased.
 
Ű¿öµå
¿ë·®ÀçÇÒ´ç;´ëû´Ù¸ñÀû´ï;È«¼öÁ¶Àý¿ë·®;´ïÀÇ Áõ°í;Reservoir Reallocation;Daechung Multi-Purpose Reservoir;Flood Control Storage;Raising Dam;
 
Çѱ¹¼öÀÚ¿øÇÐȸ³í¹®Áý / v.37, no.4, 2004³â, pp.273-281
Çѱ¹¼öÀÚ¿øÇÐȸ
ISSN : 1226-6280
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200411922315076)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿