¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹¼öÀÚ¿øÇÐȸ / v.30, no.1, 1997³â, pp.45-54
ARIMA ¸ðµ¨¿¡ ÀÇÇÑ »ó¼öµµ ÀÏÀÏ ±Þ¼ö·® ÃßÁ¤¿¡ °üÇÑ ¿¬±¸
( A Study on the Eltimation of Daily Urban Water Demand by ARIMA Model )
À̰æÈÆ;¹®º´¼®;¹Ú¼ºÃµ; Àü³²´ëÇб³ °ø°ú´ëÇÐ Åä¸ñ°øÇаú;¼­³²´ëÇб³ °ø°ú´ëÇÐ Åä¸ñ°øÇаú, µ¿½Å´ëÇб³ °ø°ú´ëÇРȯ°æ°øÇаú;;
 
ÃÊ ·Ï
¼öµ¾¹°, ¼Û¹è¼öÆßÇÁÀÇ ¿îÀü µî »ó¼öµµ½Ã¼³À» ÇÕ¸®ÀûÀÎ ¿î¿ëÀ» À§Çؼ­´Â ÀÏ, ¶Ç´Â ½Ã°£ ´ÜÀ§ÀÇ ±Þ¼ö·® »ç¿ë·®ÀÇ ÃßÁ¤ÀÌ ÇʼöÀûÀÌ´Ù°í ÇÒ ¼ö ÀÖ´Ù. ±Þ¼ö·®ÀÇ ÃßÁ¤¹æ½ÄÀº ȸ±Í¸ðÇü½Ä ¹× ½Ã°è¿­ ºÐ¼®¹æ¹ýÀÌ Àִµ¥, º» ¿¬±¸¿¡¼­´Â ½Ã°è¿­ ºÐ¼®¹æ¹ýÀÎ ARIMA¸ðÇüÀ» ÀÌ¿ëÇÏ¿© ÀÏÀÏ ±Þ¼ö·®À» ÃßÁ¤ÇÏ¿´À¸¸ç ¿¬±¸´ë»ó Áö¿ªÀ¸·Î´Â ±¤ÁÖ±¤¿ª½Ã¸¦ ¼±Á¤ÇÏ¿´´Ù. ÀÏÀÏ ±Þ¼ö·®À» ÃßÁ¤Çϴµ¥ À־ ½Ã°è¿­ÀåÀ» 15, 30. 60, 90ÀÏ·Î ³ª´©¾î °¢°¢ÀÇ ½Ã°è¿­Àå¿¡ ´ëÇØ ½ÃÇàÂø¿À¹ýÀ¸·Î °¢ ¸ðÇü¿¡ Àû¿ëÇÏ¿© ÃÖÀûÀÇ ½Ã°è¿­ÀåÀ» °áÁ¤ÇÏ¿©, »ó¼öµµ ÀÏÀÏ ±Þ¼ö·®À» ÃßÁ¤ÇÒ ¼ö ÀÖ´Â ¸ðÇüÀ» Á¦¾ÈÇÏ°í ±× À¯È¿¼ºÀ» ÀÜÂ÷ºÐ¼®À» ÅëÇØ °ËÁõÇÏ¿´´Ù. Á¦¾ÈµÈ ¸ðÇü½ÄÀº »ç°í µîÀÇ ÀÎÀ§ÀûÀÎ Á¶ÀÛ(´Ü¼ö µî)ÀÌ °¡ÇØÁö´Â ½Ã±â¸¦ Á¦¿ÜÇϰí´Â ½ÇÃøÄ¡¿Í ¸ðÇüÀÇ ÃßÁ¤Ä¡¿ÍÀÇ ¿ÀÂ÷À²ÀÌ ÃÖ´ë ¾à 12%, Æò±Õ 3% À̳»·Î ³ªÅ¸³ª, ¸ðÇüÀÇ °á°ú´Â »ó¼öµµ ÀÏÀÏ ±Þ¼ö·®ÀÇ ÃßÁ¤¿¡ ÇÊ¿äÇÑ ½Ã¼³¿¡ Àû¿ë °¡´ÉÇÏ´Ù°í ÆÇ´ÜµÈ´Ù.
The correct estimation of the daily or hourly urban water demand is required for the efficient management and operation of the water supply facilities. The prediction of water supply demand are regression model and time series method, the optimum ARIMA (Auto Regressive Integrated Moving Average) model was sought for the daily urban water demand estimation in this paper. The data used for this study were obtained from the city of Kwangju Korea. The raw data used in this study were rearranged 15, 30, 60, 90 days for the purpose of analysis. The statistical analysis was applied to the data to obtain the ARIMA model. As a result, the parameters determining the ARIMA model was obtained. The accuracy of the model was 2% of water supply. The developed model was found to be useful for the practical operation and management of the water supply facilities.
 
Ű¿öµå
 
Çѱ¹¼öÀÚ¿øÇÐȸ³í¹®Áý / v.30, no.1, 1997³â, pp.45-54
Çѱ¹¼öÀÚ¿øÇÐȸ
ISSN : 1226-6280
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO199711920100024)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿