Çѱ¹°Ç¼³°ü¸®ÇÐȸ / v.10, no.4, 2009³â, pp.111-118
|
±º º¹Áö½Ã¼³ÀÇ Áö¿½Ã½ºÅÛ°ú ž翽ýºÅÛ °æÁ¦¼º Æò°¡ »ç·Ê ¿¬±¸
( A Case Study on Economic Analysis of a Solar Water Heating System and a Ground Source Heat Pump System Applied to a Military Building ) |
| ÀÌÁ¾Âù;¹Ú¿ëÈ£;À̰;ÀÌ»óÈ£; °£»ïÆÄÆ®³Ê½ºÁ¾ÇÕ°ÇÃà»ç»ç¹«¼Ò;°£»ïÆÄÆ®³Ê½ºÁ¾ÇÕ°ÇÃà»ç»ç¹«¼Ò;¿¬¼¼´ëÇб³ °ÇÃà°øÇаú;¿¬¼¼´ëÇб³ °ÇÃà°øÇаú;
|
|
|
 |
|
| |
| ÃÊ ·Ï |
| º» ¿¬±¸´Â ±º º¹Áö½Ã¼³ÀÎ À°±º OOȸ°ü¿¡ ½Å Àç»ý¿¡³ÊÁö Áß ÅÂ¾ç¿ ¹× Áö¿½Ã½ºÅÛÀ» Àû¿ëÇßÀ» ¶§, °¢°¢ÀÇ È¿À²¼º°ú °æÁ¦¼ºÀ» ºÐ¼®ÇÏ¿© ±× ¼º´ÉÀ» Æò°¡ÇÏ¿´´Ù. ¿¬±¸ ´ë»ó °Ç¹°Àº ö±ÙÄÜÅ©¸®Æ®±¸Á¶·Î¼ °Ç¹° ±Ô¸ð°¡ ÁöÇÏ 1Ãþ Áö»ó 3ÃþÀÌ¸ç ¿¬¸éÀûÀÌ ¾à 2,917$m^2$ÀÎ °Ç¹°ÀÌ´Ù. °Ç¹°ÀÇ ¿ëµµ´Â ¸ñ¿åÅÁ, ½Ä´ç, °´½Ç ¹× »ç¹«½ÇÀ̸ç, ¿¬°£ ³Ã ³¹æ ¿¡³ÊÁö ¼Òºñ·® ÆÇ´Ü ¹× ºÐ¼®À» À§ÇØ e-Quest ½Ã¹Ä·¹À̼ÇÀ» ÀÌ¿ëÇÏ¿´´Ù. ½Å Àç»ý¿¡³ÊÁö Àû¿ë¿¡ ´ëÇÑ °æÁ¦¼º Æò°¡´Â RETScreen ½Ã½ºÅÛÀ» ÀÌ¿ëÇÏ¿´´Ù. ´Ü, ½Å Àç»ý¿¡³ÊÁö ½Ã½ºÅÛ »ç¿ëÀº ¿¬±¸´ë»ó °Ç¹°À» Ç¥Áذø»çºñ·Î ÆÇ´ÜÇßÀ» ¶§ °ø»çºñÀÇ 5% ¹üÀ§³»·Î ÇÑÁ¤ÇÏ¿´´Ù. ½Å Àç»ý ¿¡³ÊÁö½Ã½ºÅÛ Àû¿ë½Ã ž翽ýºÅÛÀº ±ÞÅÁ¿ëÀ¸·Î, Áö¿½Ã½ºÅÛÀº ³Ã¹æ¿ëÀ¸·Î ÇÏ¿´´Ù. ¿¬±¸°á°ú ž翽ýºÅÛÀÌ Áö¿½Ã½ºÅÛº¸´Ù È¿°úÀûÀ̾ú´Ù. Áö¿½Ã½ºÅÛÀº ÅõÀÚºñ »óȯ½ÃÁ¡ÀÌ ¾à 16³â 6°³¿ù ÀÌÈÄÀÎ ¹Ý¸é, ž翽ýºÅÛÀº ¾à 3³â 11°³¿ù ÀÌÈÄ¿¡ °¡´ÉÇÑ °ÍÀ¸·Î ÆÇ´ÜµÇ¾ú´Ù. ÇâÈÄ È¼®¿¡³ÊÁöÀÇ °í°¥°ú Áö±¸¿Â³È µîÀÇ ¹®Á¦ ÇØ°áÀ» À§ÇÑ ¹æ¾ÈÀ¸·Î¼ ½Å Àç»ý¿¡³ÊÁöÀÇ ÀÌ¿ë È®´ë°¡ ¿¹»óµÇ¸ç, ÀÌ¿¡ ±º¿¡¼µµ ¾ÈÁ¤ÀûÀÎ ¿¡³ÊÁö ¼ö±ÞÀ» À§ÇØ Áö¼ÓÀûÀÎ ¹ßÀüÀÌ µÇ±æ ±â¿øÇÑ´Ù. |
|
| This study is to analyze the performance of SWH(Solar Water Heating) and GSHP(Ground Source Heat Pump) systems by evaluating their energy efficiency and LCC(Life Cycle Cost) as being applied to the OO hall as a selected building in the Army. The OO hall, used as bathrooms, dining rooms, accommodations and offices, has reinforced concrete structure system with three floors above the ground and one underground, and its total floor area is approximately 2,917$m^2$. Two energy simulations are conducted to predict the yearly cooling and heating energy of the selected building: One is for analysis of an air-conditioning energy consumption using the e-Quest program, and another is for two new-renewable energy facilities as a water heating source using the RETScreen. The installed capacity of two new-renewable energy facilities is determined according to the 5% level of total standard construction cost. As a briefly result, SWH system is more energy-effective than GSHP system. Considering the break-even point, it is expected that SWH can take only 3 years 11 months to pay for itself in savings while the investment of GSHP can be recovered in more than 16 years 6 months. |
| |
| Ű¿öµå |
| ½ÅÀç»ý¿¡³ÊÁö;³Ý½ºÅ©¸°;±º º¹Áö½Ã¼³;New-Renewable Energy Sources;RETScreen;Welfare Facility in Military; |
| |
|
|
 |
|
Çѱ¹°Ç¼³°ü¸®ÇÐȸ³í¹®Áý / v.10, no.4, 2009³â, pp.111-118
Çѱ¹°Ç¼³°ü¸®ÇÐȸ
ISSN : 2005-6095
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200925265920696)
¾ð¾î : Çѱ¹¾î |
|
| ³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø |
|
|
|
|
|
|