¾ÆÆÄÆ®´ÜÁöÀÇ ±Þ¼ö·® ¹× ¿À¼ö¹ß»ý·®¿¡ ´ëÇÑ Á¶»ç ¿¬±¸
( A Study on the Water Supplies and Sewage Amount in the Apartment Complexes )
À±¿©Áø;ÃÖ¸í¼ö;¹æ±â¿õ; ´ëÇÑÁÖÅðø»ç ȯ°æ¿¬±¸ºÎ;´ëÇÑÁÖÅðø»ç ȯ°æ¿¬±¸ºÎ;´ëÀü»ê¾÷´ëÇб³ ȯ°æ°øÇаú;
 
ÃÊ ·Ï
»ýȰ¼öÁØ Çâ»ó°ú ½Ä»ýȰ º¯È­·Î ÀÎÇÏ¿© »ýȰ¿ë¼ö ¼Òºñ·®ÀÌ Áõ°¡ÇÔ¿¡ µû¶ó ÀÏ»ó»ýȰ¿¡¼­ ¹èÃâµÇ´Â ¿À¼öÀÇ ¾çµµ Áõ°¡ÇÒ °ÍÀ¸·Î ¿¹ÃøµÈ´Ù. ¾ÆÆÄÆ® ´ÜÁö³» ¿À¼öÁ¤È­½Ã¼³ ¹× Çϼöó¸®ÀåÀÇ ¼³°è¸¦ À§Çؼ­´Â ¸ÕÀú Àα¸¿¡ ±Ù°ÅÇÑ ¿À¼ö·®ÀÇ ¹ß»ý¿ø´ÜÀ§¸¦ ¾Ë¾Æ¾ß ÇÑ´Ù. ÀÌ·¯ÇÑ ÀÚ·á´Â Çϼöó¸®ÀÇ ¿îÀüÀ̳ª ¼öÁú°ü¸® °èȹ ¼ö¸³À» À§Çؼ­µµ ²À ÇÊ¿äÇÑ °ÍÀÌ´Ù. µû¶ó¼­ º» ¿¬±¸¿¡¼­´Â ÁÖÅðø»çÀÇ 123°³ °ü¸®¼Ò¿¡ 2³â°£ÀÇ ±Þ¼ö·®À» ÃëÇÕÇÏ¿© °ÅÁÖÀα¸¿¡ µû¸¥ ±Þ¼ö·®À» ºÐ¼®ÇÏ¿´°í ±× Áß¿¡ ¼öµµ±Ç 1°³ ´ÜÁö¿Í Áö¹æ±Ç 1°³ ´ÜÁö¸¦ ¼±Á¤ÇÏ¿© ½Ã°£º°, ÀϺ°, ¿äÀϺ°, °èÀýº°ÀÇ ¿À¼öÀ¯ÀÔ·®À» Á÷Á¢ ½ÇÃøÇÔÀ¸·Î½á ½ÇÁ¦ ±Þ¼ö·®°ú ºñ±³¸¦ ÅëÇÏ¿© ¿À¼öÀ¯ÀÔ ÃÑ·® ¹× °ÅÁÖÀα¸¿¡ µû¸¥ ¿ø´ÜÀ§¸¦ °è»êÇÏ¿´´Ù. Çٽɿë¾î : ±Þ¼ö, À¯ÀÔ¿À¼ö, ¿ø´ÜÀ§
As an improvement on qualities of lives and a change in the habitual ways people eat require more water to be used for daily lives, the amount of wastewater generated from our usual lives is also expected to be in higher rate of consumption. The unit loading factor of sewage flow-rate based upon the number of people living in the apartment complexes has to be found for the design of the sewage or wastewater treatment facilities. These data are definitely thought to be useful for the plans to operate the sewage treatment facilities and for those to establish the plans toward a management of water qualities. Thus this study has shown that the data regarding the water supplies and the number of apartment residents within the 123 districts of KNHC(Korea National Housing Corporation) were collected and analyzed. One district in Seoul and the other local district were chosen an the experimental sites for th hourly, daily, weekly and seasonal measurements of the influent sewage flow-rate. The unit loading factor of influent sewage flow-rate were determined through the comparison of total sewage amount in combination with the number of people residing in two apartment complexes with supplying amount of water.Keywords : supplying water, influent sewage, unit loading factor
 
Ű¿öµå
±Þ¼ö;À¯ÀÔ¿À¼ö;¿ø´ÜÀ§;supplying water;influent sewage;unit loading factor;
 