¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹¼öÀÚ¿øÇÐȸ / v.39, no.7, 2006³â, pp.583-592
Åõ°úÀ²°ú ¼³Ä¡°¢µµ¿¡ ´ëÇÑ ¼öÁ¦ÁÖº¯ ¼¼±¼¿µ¿ª¿¡ °üÇÑ ½ÇÇè ¿¬±¸
( An Experimental Study on Scout Area around Groynes with Permeability and Install Angle )
¿©È«±¸;°­Áر¸;±è¼ºÁß;³ë¿µ½Å; Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ¼öÀÚ¿ø¿¬±¸ºÎ;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ¼öÀÚ¿ø¿¬±¸ºÎ;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ¼öÀÚ¿ø¿¬±¸ºÎ;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ¼öÀÚ¿ø¿¬±¸ºÎ;
 
ÃÊ ·Ï
¼öÁ¦¼³Ä¡·Î ÀÎÇØ ¹ß»ýµÇ´Â ¼¼±¼°øÀº ¼öÁß»ý¹°ÀÇ ´Ù¾çÇÑ ¼­½Äó ¹× È«¼ö ½Ã ¾î·ùÀÇ Çdz­Ã³ Á¦°ø µî ȯ°æ ±â´ÉÀ» ³»Æ÷ÇÒ ¼ö ÀÖ´Ù´Â °üÁ¡ÀÌ ºÎ°¢µÇ°í ÀÖÀ¸¸ç ÀÌ¿Í °°Àº ¿ä±¸¸¦ ÃæÁ·Çϱâ À§Çؼ­´Â ±âÁ¸ÀÇ ¾ÈÁ¤¼º ¹®Á¦¿¡ ´ëÇÑ °üÁ¡¿¡¼­ ¹þ¾î³­ ¼öÁ¦ÁÖº¯ ¼¼±¼¿µ¿ª¿¡ ´ëÇÑ ¿¬±¸°¡ ÇÊ¿äÇÏ´Ù. »ýż­½Äó·ÎÀÇ ¼¼±¼¿µ¿ªÀº ¼öÁ¦ÇüÅ¿¡ µû¶ó ´Ù¾çÇÑ ÇüŰ¡ »ý¼ºµÉ ¼ö ÀÖÀ¸¹Ç·Î ÀÌ¿¡ ´ëÇÑ ºÐ¼®ÀÌ ¿ä±¸µÈ´Ù. º» ¿¬±¸´Â Åõ°úÀ²°ú ¼³Ä¡°¢µµ¸¦ º¯È­ÇÑ ½ÇÇèÀ» ÅëÇØ ¼öÁ¦ÁÖº¯ ¼¼±¼±Ô¸ð¸¦ ÆÄ¾ÇÇÏ¿© ȯ°æÀûÀÎ Ãø¸éÀÇ ¼öÁ¦¼±Á¤ÀÇ ÀڷḦ Á¦¾ÈÇϴµ¥ ¸ñÀûÀÌ ÀÖ´Ù. ½ÇÇè¿¡ Àû¿ëµÈ Åõ°úÀ²Àº ºÒÅõ°ú(0% Åõ°ú)¿Í Åõ°ú¼öÁ¦(20%, 40%, 60%, 80%)ÀÌ¸ç ¼³Ä¡°¢Àº $60^{circ},;90^{circ},;120^{circ}$ÀÌ´Ù. ½ÇÇè°á°ú, °¢ ½ÇÇèÁ¶°Ç¿¡ µû¸¥ ÃÖ´ë¼¼±¼ ¹ß»ý½ÃÀÇ ¼¼±¼¿µ¿ª°ú ¼¼±¼½ÉÀ» ºÐ¼®ÇÒ ¼ö ÀÖ¾úÀ¸¸ç ¼öÁ¦Á¶°Ç¿¡ ´ëÇÑ Â÷À̸¦ Á¦½ÃÇÏ¿´´Ù.
There has been debated on the fact that a scour hole produced by the construction of a groyne has environmental benefits such as provision of diverse underwater habitats and shelter for fish in the event of flooding. Therefore researches are focusing on the scour field around the groyne area beyond the existing safety issues. The scour area on aquatic habitats would format many form on groyne conditions so that the analysis of scour area is strongly required. This study conducted the experiments on permeability and installation angle of groyne and suggested the data for groyne selection in environmental point as analyzing scour area. The physical modeling was performed in different permeability (0%, 20%, 40%, 60%, 80%) and installation angle of groyne ($60^{circ},;90^{circ},;120^{circ}$). As the result of the study, scour area and scour depth at maximum scour condition was revealed for each case and suggested the differences according to experiment conditions.
 
Ű¿öµå
¼öÁ¦;Åõ°úÀ²;¼³Ä¡°¢µµ;¼¼±¼¿µ¿ª;ÃÖ´ë¼¼±¼½É;groyne;permeability;installation angle;scour area;maximum scour depth;
 
Çѱ¹¼öÀÚ¿øÇÐȸ³í¹®Áý / v.39, no.7, 2006³â, pp.583-592
Çѱ¹¼öÀÚ¿øÇÐȸ
ISSN : 1226-6280
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200633242282818)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿